TRANE E4HL5024A1000A Split System Heat Pump

Product Information

  • Product: Split System Heat Pump
  • Model: E4HL5024A1000A
  • Dimensions (in inches):
    • A: 31.35
    • B: 35.83
    • C: 14.13
    • D: 15.36
    • E: 16.59
    • F: 5.97
    • G: 6.07
    • H: 3.71
    • I: 6.09
  • Noise Level (A-Weighted Sound Power Level):
    • 63Hz*: 58 dB(A)
    • 125Hz: 56 dB(A)
    • 250Hz: 48 dB
    • 500Hz: 46 dB
    • 1000Hz: 44 dB
    • 2000Hz: 55 dB
    • 4000Hz: 50 dB
    • 8000Hz: 38 dB

Product Specifications

  • Outdoor Unit Power Connections: 208/230V, single phase, 60Hz
  • Minimum Circuit Ampacity : 21.5 Amps
  • Max. Overcurrent Protection: 35 Amps
  • Compressor Type: Rotary, Variable Speed
  • Compressor Heat Outdoor Fan Diameter: 21-5/8 inches
  • No. of Motors: 1
  • Motor Speed: Variable, 1-1/10 HP
  • CFM @ 0.0 IN. W.G. : 2700
  • Outdoor Coil Type : Plate Fin
  • Rows : 1-21
  • F.P.I.: 8.18
  • Face Area : 3/8 sq. ft.
  • Tube Size : 3/8 inches
  • Refrigerant Control: Electric Expansion Valve
  • Weight : Shipping Net – 161 lbs, 1 oz

Product Usage Instructions

  • Ensure that the power connections are compatible with the bunit’s requirements: 208/230V, single phase, 60Hz.
  •  Determine the minimum circuit ampacity for the installation. It should be at least 21.5 Amps.
  • Install the appropriate overcurrent protection, with a maximum rating of 35 Amps.
  • Place the unit in an outdoor location with sufficient clearance for proper airflow.
  • Connect the compressor heat outdoor fan, ensuring it is properly aligned and securely attached.
  • Connect the motor to the unit, ensuring the motor speed is set to variable and the horsepower is set to 1-1/10 HP.
  • Adjust the CFM (cubic feet per minute) to 2700 at 0.0 inches water gauge.
  • Install the outdoor coil, ensuring it is a plate fin type and has 1-21 rows with a fin per inch (F.P.I.) of 8.18.
  • Ensure the face area of the coil is 3/8 square feet and the tube size is 3/8 inches.
  • Connect the electric expansion valve for refrigerant control.
  • The unit weighs 161 lbs, 1 oz and should be handled accordingly during shipping and installation.
    Note: For more detailed instructions and safety precautions, please refer to the complete user manual.

DIMNSION

Model A B C D E F G H I
E4HL5024A1000A 31.35 35.83 14.13 15.36 16.59 5.97 6.07 3.71 6.09

All dimensions are in inches

NOTE: ALL DIMENSIONS ARE REFERENCE DIMENSIONS

SOUND POWER LEVEL

Model| A-Weighted Sound

Power Level [dB(A)]

| Full Octave Sound Power [dB]
63Hz| 125Hz| 250Hz| 500Hz| 1000Hz| 2000Hz| 4000Hz| 8000Hz
E4HL5024A1000A| 58| 56| 48| 46| 44| 55| 50| 38| 29
Note: Rated in accordance with AHRI Standard 270–2015
For reference only.

Product Specifications

OUTDOOR UNIT (a) E4HL5024A1000A
POWER CONNS. — V/PH/HZ (b) 208/230/1/60
MIN. CIR. AMPACITY 21.5

MAX. OVERCURRENT

PROTECTION

| 35
COMPRESSOR| Rotary
NO. USED — NO. STAGES| 1-VARIABLE
VOLTS/PH/HZ| 208/230/1/60
R.L. AMPS (c)| 15.8
FACTORY INSTALLED|
START COMPONENTS (d)| NO
INSULATION/SOUND BLANKET| YES
COMPRESSOR HEAT| NO
OUTDOOR FAN| PROPELLER
DIA. (IN.) — NO. USED| 21-5/8″-1
TYPE DRIVE — NO. SPEEDS| DIRECT — VARIBLE
NO. MOTORS — HP| 1-1/10
CFM @ 0.0 IN. W.G. (e)| 2700
MOTOR SPEED R.P.M.| 850
VOLTS/PH/HZ| 208/230/1/60
F.L. AMPS| 1.1
OUTDOOR COIL — TYPE| PLATE FIN
ROWS — F.P.I.| 1-21
FACE AREA (SQ. FT.)| 8.18
TUBE SIZE (IN.)| 3/8″
REFRIGERANT CONTROL| ELEC. EXPANSION

VALVE

REFRIGERANT|
LBS. – R-410A (O.D. UNIT) (f)| 5 LBS, 1 OZ
FACTORY SUPPLIED| YES
LINE SIZE — IN. O.D. GAS| 3/4″
LINE SIZE — IN. O.D. LIQ.| 3/8″
CHARGING SPECIFICATIONS|
SUBCOOLING| 5°F
DIMENSIONS| H x W x D
CRATED (IN.)| 40-1/4″×32-7/8″×18-

7/8″

UNCRATED (IN.)| 35-3/4″×31-5/8″×14-

1/8″

WEIGHT|
Shipping| 161
Net (Lbs.)| 104

  • Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program, which is based on AHRI standard 210/240.
  •  Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses.
  • This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current.
  •  No means no start components.
  • Standard Air — Dry Coil — Outdoor
  • This value is approximate. For more precise value see unit nameplate.

Mechanical Specification Options

General
The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 60335-2-40. Exterior is designed for outdoor application.

Casing
Unit is painted with a glossy corrosion resistant finish on all panels. Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint finish. All panels are subjected to our 500 hour salt spray test.

Refrigerant Controls
Refrigeration system controls include condenser fan, compressor drive and low pressure switches.

Compressor
The compressor features external over temperature and pressure protection. Other features include: Centrifugal oil pump and low vibration and noise.

Condenser Coil
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grilles and panels.

Low Ambient Cooling
As manufactured, this system has a cooling capacity to 5°F.

ABOUT COMPANY

  • About Trane and American Standard Heating and Air Conditioning
  • Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com
  • The AHRI Certified mark indicates company participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org.
  • The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.
  • E4HL5024A-SUB-1A-EN 24 Apr 2023