DIGITALas DI-HF4 Outdoor FingerKey and Reader User Manual

June 13, 2024
DIGITALas

DIGITALas DI-HF4 Outdoor FingerKey and Reader

INTRODUCTION

The device is a single door multifunction standalone access controller or a Wiegand output reader. It uses Atmel MCU assuring stable performance. The operation is very user-friendly, and low-power circuit makes it long service life. The device supports 1,000 users (988 common users + 2 panic users + 10 visitor users), all user data can be transferred from one to another (except fingerprint users). It supports multi access modes in card access, PIN access, fingerprint access, card + PIN access, or multi cards /PINs/ fingerprints access. It has extra features including block enrollment, interlock, Wiegand input & output interface…etc.
Three Versions Optional:

  • The device with Bluetooth function is optional
  • The device with big user capacity is optional
  • The device with WiFi function is optional

Simplified Instruction

Features

  • Capacitive fingerprint sensor, Touch key

  • Metal case, anti-vandal

  • Waterproof, conforms to IP66

  • One relay, 1,000 users (988 common + 2 panic + 10 visitor)

  • PIN length: 4~6 digits

  • EM card, EM+ Mifare cards optional

  • EM card: Wiegand 26~44 bits input & output
    Mifare card: Wiegand 26-44bits, 56bits, 58bits input & output

  • Can be used as Wiegand reader with LED & buzzer output

  • Card block enrollment

  • Tri-color LED status display

  • Integrated alarm & buzzer output

  • Pulse mode, Toggle mode

  • User data can be transferred (except fingerprint users)

  • 2 devices can be interlocked for 2 doors

  • Built-in light dependent resistor (LDR) for anti tamper

  • Backlit keypad, can set automatic OFF after 20 seconds

Specifications

Carton Inventory

INSTALLATION

  • Remove the back cover from the unit
  • Drill 2 holes(A,C) on the wall for the screws and one hole for the cable
  • Knock the supplied rubber bungs to the screw holes(A,C)
  • Fix the back cover firmly on the wall with 4 flat head screws
  • Thread the cable through the cable hole(B)
  • Attach the unit to the back cover

Wiring

Sound and Light Indication

Basic Configure

Enter and Exit Program Mode

Set Master Code

Set the Working Mode
Notes: The device has 3 working modes: Standalone Mode, Controller Mode, Wiegand Reader Mode, choose the mode you use. (Factory default is Standalone Mode / Controller Mode)

STANDALONE MODE

The device can work as Standalone Access Control for single door. (Factory default mode) — 7 7 #

Connection Diagram

  • Common Power Supply
    Attention:

    Install a 1N4004 or equivalent diode is needed when use a common power supply, or the keypad might be damaged. (1N4004 is included in the packing)

  • Access Control Power Supply

    • Programming
      Programming will be vary depending on access configuration. Follow the instructions according to your access configuration.
      Notes:

      User ID number: Assign a user ID to the access fingerprint/ card/ PIN in order to track it.

    • The Common User ID:

    • Fingerprint user ID: 0 ~ 98

    • PIN/ Card user ID: 100 ~ 987
      Master Fingerprint User ID: 99
      Panic User ID: 988~989
      Visitor User ID: 990~999

    • IMPORTANT: User IDs do not have to be proceeded with any leading zeros. Recording of User ID is critical. Modifications to the user require the User ID be available.

    • Proximity Card:
      Proximity Card: EM card/ EM+ Mifare cards

    • PIN: Can be any 4-6 digits except 8888 which is reserved.

  • Add Common Users
    (Fingerprint user ID: 0 ~ 98, PIN/ Card user ID: 100 ~ 987; PIN length: 4~6 digits except 8888)
    Tips for PIN Security (Only valid for 6 digits PIN): For higher security we allow you to hide your correct PIN with other numbers up to a max of 10 digits.
    Example PIN: 123434
    You could use (123434) or * (123434) (“” can be any numbers from 0~9)

  • Add Master Fingerprint (By Specified ID: 99)

  • Add Panic Users (Valid for Card/ PIN Users)
    (User ID number is 988, 989; PIN length: 4~6 digits except 8888)

  • Add Visitor Users (Valid for Card/ PIN Users)
    (User ID number is 990~999; PIN length: 4~6 digits except 8888) There are 10 groups Visitor PIN/card available, the users can be specified up to 10 times of usage, after a certain number of times, i.e. 5 times, the PIN/card become invalid automatically.

Change PIN Users(PIN length: 4~6 digits except 8888)
(Note: WiFi versions don’t support change PIN)

Delete Users

Set Relay Configuration
The relay configuration sets the behaviour of the output relay on activation.

Set Access Mode
For Multi user access mode, the interval time of reading can not exceed 5 seconds, or else, the device will exit to standby automatically.

Set Strike-outAlarm
The strike-out alarm will engage after 10 failed entry attempts (Factory is OFF). It can be set to deny access for 10 minutes after engaging or disengage only after entering a valid Finerprint/ card/ PIN or Master code/ fingerprint/ card.

Set Door Open Detection

  • Door Open Too Long (DOTL) Detection
    When use with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically to remind people to close the door. The beep can be stopped by closing the door, master users or valid users, or else, it will continue to beep the same time with the alarm time set.

  • Door Forced Open Detection
    When use with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened by force, the inside buzzer and external alarm (if there is) will both operate, they can be stopped by master users or valid users, or else, it will continue to sound the same time with the alarm time set.

The function of Set Alarm Time also apply for anti-tamper alarm

Set Audible and Visual Response

Master Fingerprint/ Card Usage

Users Operation & Reset to Factory Default

  • Open the door: Read valid user fingerprint or user card or input valid user PIN #
  • Remove Alarm: Enter Master Code # or Master Fingerprint/ Card orvalid user fingerprint/card / PIN
  • To reset to factory default & Add Master Card: Power off, press the Exit Button, hold it and power on, there will be two beeps, then release the exit button, the LED light turns into yellow, then read any 125KHz EM card / 13.56MHz Mifare card, the LED will turn into red, means reset to factory defau successfully. Of the card reading, it is the Master Card.

Remarks:

  1. If no Master Card added, must press the Exit Button for at least 5 seconds before release. (this will make the previous registered Master Card invalid)
  2. Reset to factory default, the user’s information is still retained.

CONTROLLER MODE

The device can work as Controller, connected with the external Wiegand reader. (Factory default mode) — 7 7#

Connection Diagram

Attention: Install a 1N4004 or equivalent diode is needed when use a common power supply, or the reader might be damaged. (1N4004 is included in the packing)

Set Wiegand Input Formats
Please set the Wiegand input formats according to the Wiegand output format of the external Reader.

Note: For connecting Wiegand readers with 32, 40, 56 bits output, need disable parity bits.

Programming

  • Basic Programming is the same as Standalone Mode

  • There are some exceptions for your attention:
    The device Connected with External Card Reader

    • If EM/Mifare card reader: users can be added/deleted on either the device or external reader.
    • If HID card reader: users can only be added deleted on extemal reader.

The device Connected with Fingerprint Reader
For example: Connect SF1 as the fingerprint reader to the device.

  • Step 1: Add the Fingerprint (A) on SF1 (Please refer to SF1 manual)
  • Step 2: Add the same Fingerprint(A) on the device:

The device Connected with Keypad Reader

The keypad reader can be 4 Bits, 8 Bits (ASCIl), or 10 Bits output format. Choose the below operation according to the PIN output format of vour reader.

Remarks: 4 means 4 bits, 8 means 8 bits, 10 means 10 digits virtual number.

  • Add PIN Users:
    To add PIN users, after enter into programming mode on the device, PIN(s) can be input/ added on either the device or the external Keypad Reader.

  • Delete PIN Users: the same way as add users.

WIEGAND READER MODE

The device can work as Standard Wiegand Reader, connected to the third party Controller. _. 78 #

Connection Diagram

Notes:

  • When set into Wiegand Reader mode, nearly all settings in Controller Mode will become invalid, and Brown & Yellow wires will be redefined as below:
    • Brown wire: Green LED light control
    • Yellow wire: Buzzer control
  • If you need to connect Brown/Yellow wires:
    When the input voltage for LED is low, the LED will turn into Green; and when the input voltage for Buzzer is low, it will sound.

Set Wiegand Output Formats
Please set the Wiegand output formats of Reader according to the Wiegand input formats of the Controller.

Note: For connecting Wiegand controller with 32, 40, 56 bits input, need disable parity bits

ADVANCED APPLICATION

Collection Card Mode
After this mode is turned on, all cards can open the lock. At the same time, the card is added to the device.

User Information Transfer (Valid for Card / PIN Users)
The device supports the User Information Transfer function, and the enrolled user (cards, PINs) can be transferred from one (let’s name it Master Unit) to another (let’s name it Accept Unit).

Connection Diagram:

Remarks:

  • The Master units and Accept units must be same series devices.
  • The Master Code of the Master Unit and the Accept Unit must be set to the same.
  • Program the transfer operation on Master Unit only.
  • If the Accept Unit is already with the users enrolled, it will be covered after transferring.
  • For full 900 users enrolled, the transfer takes about 30 seconds.

Set Transferring on Master Unit:

Interlock
The device supports the Interlock Function. It is of two Devices for two doors, and mainly used for banks, prisons, and other places where a higher level security is required.

Connection Diagram:

Remarks: The Door Contact must be installed and connected as the diagram.
Let’s name the two Devices as “A “and “B” for two doors “1” and «2″

  • Step 1: Enroll the users on Device A, then transfer the users’ information to Device B by “User Information Transfer” funciton.
  • Step 2: Set both of the two Devices (A and B) to Interlock function.

If enable interlock, when and only door 2 is closed, the user can read the valid fingerprint/card or input PIN on Reader A, door 1 will open; then when and only door 1 closed, read valid fingerprint/card or input PIN on Reader B, door 2 will open.