DIGITALAS AD7 Access Control-Reader User Manual
- June 3, 2024
- DIGITALas
Table of Contents
DIGITALAS AD7 Access Control-Reader
INTRODUCTION
This product is a contactless EM proximity card standalone access control. It adopts zinc alloy case, anti-vandal and anti-explosion, 2,000 user capacity, and supports access by card, card + PIN, card or PIN. Wiegand 26 Output/Input.
Features and Benefits
- Zinc-alloy housing, anti-vandal, anti-explosion
- Water proof, conforms to IP67
- User capacity: 2000
- Length of PIN: 4 – 8 digits
- Wide voltage input: DC 10-24V
- Supporting block enrollment with cards sequentially numbered Pulse Mode, Toggle Mode
- Wiegand 26 Output/Input, PIN Visual card number output Admin can add/delete admin cards, making add/delete cards rapidly.
Specifications
Operating Voltage | 10-24V DC |
---|---|
Idle Current | ≤40mA |
Working Current | ≤80mA |
Weatherproof | IP67 |
Read Range | ≤6cm |
User Capacity | 2000 |
Card type | EM Card |
Card Frequency | 125KHz |
Lock Output Load | ≤2A |
Alarm Output Load | ≤1A |
Operating Temperature | -40°C~+70°C,(-40°F~158°F) |
Operating Humidity | 10%~98%RH |
Dimensions | L110xW76xH22mm(Wide) |
L129xW44xH20mm(Slim)
Unit Weight| 460g (Wide), 350g (Slim)
Shipping Weight| 520g (Wide), 410g (Slim)
Packing List
INSTALLATION
- Remove the back cover from the unit with a screw.
- Drill holes in the wall according to the back side of the machine and fix the back cover to the wall. (or fix the back cover firmly to the 86cm×86cm box)
- Thread the cable through the cable hole, and connect the related cable. For the unused cable please separate it with insulating tape.
- After wiring, install front casing to the back casing and fix it well.
Wiring
Sound and Light Indication
Operation Status | Light | Buzzer |
---|---|---|
Stand by | Red light bright | |
Enter programming mode | Red light shines | |
In the programming mode | Orange light bright | |
Open lock | Green light bright | One beep |
Operation failed | **** | 3 beeps |
Factory Default settings and add admin cards
Power off, press exit button, power on, and release it until hear two beeps.
Swiping two cards, the first card is the “Admin Add Card”, the second card is
the “Admin Delete Card”, then the device will be in standby mode. Resets to
factory default setting and adding admin cards are successful.
If you don’t need to add admin cards: Power off, press exit button, power on,
and release it until hearing two beeps, and the orange LED turn on. After
waiting for ten seconds, there is a beep and it will be in standby mode.
Resets to factory default setting is successful.
Reset to factory default, the users’ information won’t be deleted.
STANDALONE MODE
Connection Diagram Special Power Supply for access control system
Common power supply
Attention: Install a 1N4004 or equivalent diode is needed when use a common
power supply, or the reader might be damaged.(1N4004 is included in the
packing).
Quick Start and Operation
Quick Settings
Enter the Programming Mode
| *** T – Admin Code – #**
hen you can do the
programming
(Factory default is 777777)
Change the Admin Code
| 0 – New Code – # – Repeat the New Code – #
(New Code: any 6 digits)
Add Card User| 1 – Read Card – # (Cards can be added in continuously)
Add PIN User| 1- User ID – # – PIN- #
(ID number:1-2000)
Delete User
| 2 – Read Card – #
(for Card User)
2 – User ID-#
(for PIN User)
Exit from the Programming Mode| ***
How to release the door**
Open door by card| (Read Card)
Open door by User PIN| (Users PIN) #
Open door by user card + PIN| (Read Card) (Users PIN) #
Add/Delete Users by Admin Card
Using Admin Cards to add delete card users
Add users
| Step 1: Read Admin Add Card Step 2: Read user cards
(Repeat step 2 for additional user cards) Step 3: Read Admin Add Card again to end
Delete users
| Step 1: Read Admin Delete Card)
Step 2: Read user cards
(Repeat step 2 for additional user cards) Step 3: Read Admin Delete Card again to end
Enter and Exit Program mode
Programming Step | Keystroke Combination |
---|---|
Enter Program Mode | * (Admin Code) # |
(Factory default is 777777)
Exit Program Mode| *
Modify Admin Code
Programming Step | Keystroke Combination | LED |
---|---|---|
Enter Program Mode | * (Admin Code) # | Red shines |
Update Admin Code
| 0 (New Admin Code) # (Repeat New Admin Code) # (Admin Code is any 6 digits)|
Orange bright
Exit Program Mode| *| Red bright
The length of the admin code is 6 digits, the admin should keep it in mind
Add Users by Keypad (ID Number:1-2000)
Programming Step | Keystroke Combination | LED |
---|---|---|
Enter Program Mode | * (Admin Code) # | Red shines |
Add Card User
Add Card: by Card
OR
Add Card: by ID number
OR
Add proximity cards sequentially numbered
| 1 (Read Card) #
1 (Input ID number) # (Read Card) #
8 (ID number) # (8/10 digits card number) # (The number of cards)#
|
Orange bright
Add PIN users| 1 (ID Number) # (4-8 digits PIN)| Orange bright
Exit Program Mode| *| Red bright
Note: 1. When swiping cards to add users, the user ID will be added in
automatically, and ID number will be from small to big, ranged from 1 –
2000.When adding card users, an attached PIN 1234 will be added in
automatically. This pin cannot used to open door. If you want to open door by
card + PIN, you should first change the old PIN 1234, method referring to
Change PIN.
Before add the proximity cards sequentially numbered,
the ID number should be sequential and empty.
Delete Users by Keypad
Programming Step | Keystroke Combination | LED |
---|---|---|
Enter Program Mode | * (Admin Code) # | Red shines |
Delete Card User-Common
Delete Card – By Card
OR
Delete Card –
By ID number
| 2 (Read Card) #
2 (Input ID number) #
| ****
Orange bright
Delete All User| 2 0000 #| Orange bright
Exit Program Mode| *| Red bright
Pulse Mode and Toggle Mode Setting
Programming Step | Keystroke Combination | LED |
---|---|---|
Enter Program Mode | * (Admin Code) # | Red shines |
Pulse Mode | 3 (1-99) # | Orange bright |
Toggle Mode | 3 0 # | |
Exit Program Mode | * | Red bright |
Note: 1. Factory default is Pulse Mode and the access time is 5 Pulse
Mode: The door will be closed automatically after opening the door for a
while.
Toggle Mode: Under this mode, after opening the door, the door won’t be closed
automatically until next valid user input. That is to say, whether open or
close the door, you must swipe valid card or input valid PIN.
Access Mode Setting
Programming Step | Keystroke Combination | LED |
---|---|---|
Enter Program Mode | * (Admin Code) # | Red shines |
Open door by card
OR
Open door by card + PIN
OR
Open door by card or PIN
| 4 0 #
4 1 #
4 2 # (Factory default)
|
Orange bright
Exit Program Mode| *| Red bright
Alarm Output Time Setting
Programming Step | Keystroke Combination | LED |
---|---|---|
Enter Program Mode | * (Admin Code) # | Red shines |
Set alarm time | 6(1-3) # | Orange bright |
Exit Program Mode | * | Red bright |
Note Factory default is 1 minute. Alarm output time includes: the alarm
time of anti-vandal, safe mode and closing reminder.
Swipe valid card or Input valid PIN can remove the alarm.
Set Safe Mode
Programming Step | Keystroke Combination | LED |
---|---|---|
Enter Program Mode | * (Admin Code) # | Red shines |
Normal Mode
OR
Lockout Mode
OR
Alarm output Mode
| 7 0 # (Factory default)
7 1 #
7 2 #
|
Orange bright
Exit Program Mode| *| Red bright
Note: Lockout Mode: If swipe card/input PIN with invalid users for 10
times in 1 minute, the device will be lockout for 10 minutes. When the device
repowered, the lockout will be canceled.
Alarm Output Mode: If swipe card/input PIN with invalid users for 10 times in
1 minute, the buzzer built-in will be activated.
Door Detection Setting
Programming Step | Keystroke Combination | LED |
---|---|---|
Enter Program Mode | * (Admin Code) # | Red shines |
To disable door detection | 9 0 # (Factory Default) | Orange bright |
To enable door detection | 9 1 # | |
Exit Program Mode | * | Red bright |
Note: After enable the door detection function, you must connect the detection switch into the wiring. There will be two detection status:
- The door is opened by valid user, but not closed in 1 minute, the device will beep.
- How to stop the warnings: Close the door/valid user/Automatically stop when the alarm time is up.
- If the door opened by force, the device and external alarm will activate.
- How to stop the alarm: Valid user/Automatically stop when the alarm time is up.
WIEGAND READER MODE
Connection Diagram
Note: When the device is used as salve reader, the Wiegand output format of the card is 26 bits; the format of PIN is virtual card number output.
DOOR BELL WIRING
Users Setting
Change PIN
Programming Step | Keystroke Combination |
---|---|
Change PIN which attached to card users | * (Read Card) (old PIN) # (New PIN) # |
(Repeat New PIN) #
Change independent PIN| *(ID number) # (old PIN) # (New PIN) #
(Repeat New PIN) #
How to release the door
Open door by card | (Read Card) |
---|---|
Open door by User PIN | (Users PIN) # |
Open door by user card + PIN | (Read Card) (Users PIN) # |
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>