BRISTAN QS-V108852 Mila Pair Of Basin Taps User Guide
- June 4, 2024
- BRISTAN
Table of Contents
Product Code: MI 1/2 C (D2)
Installation Instructions
& User Guide
Please leave these instructions with the end user
Specifications
Inlet Water Temperature | Dynamic Water Pressure | Inlet Connections |
---|---|---|
Maximum Static Pressure: 10.0 bar |
Tools You’ll Need
Prior to Installation
All products manufactured and supplied by Bristan are safe to use provided
that they are installed, operated, and receive regular maintenance in
accordance with these instructions.
This product needs to be installed in accordance with, and meet the
requirements of the Water Supply (Water Fittings) Regulations 1999 and current
by-laws. For full Installation Requirements & Notes (IRN) please visit
wras.co.uk/directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease of
future maintenance.
Before installing this product the water supply must be thoroughly flushed in
order to remove any swarf, solder, etc. Full access must be made available for
future maintenance/ servicing purposes.
This product must not be modified in any way as this will invalidate the
guarantee.
If in doubt, contact a registered plumber, your Local Water Authority, or the
Secretary of the Institute of Plumbing, address as follows:-
The Institute of Plumbing, 64 Station Lane, Hornchurch, Essex,
RM12 6NB, Tel: 01708 472791
Pack Contents
Spare Parts
To replace any spare parts for your tap, why not scan the QR Code or visit www.bristan.com and search for your product?
Installation
Fit the taps to the basin, ensuring the plinth is in place.
Secure the taps to the basin by using the washer and metal back nuts below the basin.
Connect the hot and cold water supplies to the threaded tails.
Operation
Maintenance – Clean/Replace Outlet
Check for damage. Soak using a suitable solution to de-scale.
Screw back into the tap body to replace the outlet.
General Cleaning
Bristan products are made from premium materials, with hand polishing and
electroplated finishes.
Your taps or shower should be regularly cleaned with warm water, a mild pH-
neutral liquid soap, and polished with a soft cloth.
Any residues from soap, toothpaste, shampoos, and shower gels can cause
blemishes if not rinsed off straight after use. Household bleaches and
cleaners contain harsh chemicals and may damage the surface finish. Avoid
using abrasive cloths, scouring pads, scrub sponges, steel wool, or anything
similar.
Some surfaces such as nickel and pewter may be affected by the dye found in
some cloths, so it is also important to avoid hanging cloths on spouts.
Maintenance – Valve Cleaning
Unscrew the handle washer to remove the handles.
Remove the valve using long-nosed pliers. Check any seals and O-rings for
damage.
Replace valve if necessary.
Place valves in a suitable solution and soak until fully de-scaled.
Reverse the steps to replace the valves and handles.
Troubleshooting
Symptom | Cause | Remedy |
---|
No flow or low flow rate
| Partially closed isolation valve.| Open isolation valve.
Instantaneous water heater cycles on and off as the flow rate or pressure is
too low.| Increase water flow rate or pressure through the system.
The Head of water is below the minimum distance required.| Refer to the
specification for the minimum distance required.
Hot or cold water being drawn off elsewhere causes pressure changes or
instantaneous boiler temperature changes.| Do not use other water outlets when
using the taps.
Airlock or partial blockage in the supply pipework.| Flush through pipework to
ensure the removal of debris and any airlocks.
Water dripping from taps| This is normal for a short time after using the
taps.| This is caused by residual water tension, the build-up of water in the
tap body.
If water continues to drip, possibly due to the ceramic disc valves| Remove
valves and clean them, refer to the ‘Maintenance’ section before starting any
maintenance.
Taps do not turn on| Closed isolation valve.| Open isolation valve.
The mains water supply was turned off.| Turn on the mains water supply.
Notes
Contact Us
Bristan Group Ltd.
UK: Bristan Group, B78 1SG.
EU: Masco Europe S.à.r.l. 14 Rue Strachen 6933 Mensdorf Luxembourg
Customer Service: +44330 026 6273
Web: www.bristan.com
Email: enquire@bristan.com
A Masco Company
Our Guarantee
At Bristan, we want to make things as easy as possible for our customers.
That’s why we offer solid guarantees on all our products, effective from the
date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your
product.
Alternatively, visit
www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273 where
our expert team of advisors will be able to offer you any help and advice.
For full guarantee terms and conditions visit www.bristan.com/service-
centre/guarantees.
References