true FCA23 Sollatek Temp Control Installation Guide
- June 13, 2024
- TRUE
Table of Contents
- FCA23 Sollatek Temp Control
- Overview
- 1| 43 (6.1)| 37 (2.7)| 40 (4.4)
- 2| 42 (5.5)| 36 (2.2)| 39 (3.9)
- 3| 41 (5.0)| 35 (1.6)| 38 (3.3)
- 4| 40 (4.4)| 34 (1.1)| 37 (2.8)
- 5| 39 (3.8)| 33 (0.5)| 36 (2.2)
- 6| 38 (3.3)| 32 (0.0)| 35 (1.7)
- 7| 37 (2.7)| 31 (-0.6)| 34 (1.1)
- 8| 36 (2.2)| 30 (-1.2)| 33 (0.5)
- 9| 35 (1.6)| 29 (-1.7)| 32 (0.0)
- 1| 74 (23.3)| 68 (20.0)| 71 (21.7)
- 2| 70 (21.1)| 64 (17.8)| 67 (19.5)
- 3| 66 (18.9)| 60 (15.6)| 63 (17.3)
- 4| 62 (16.6)| 56 (13.3)| 59 (15.0)
- 5| 58 (14.4)| 52 (11.1)| 55 (12.8)
- 6| 54 (12.2)| 48 (8.9)| 51 (10.6)
- 7| 50 (10.0)| 44 (6.7)| 47 (8.4)
- 8| 46 (7.7)| 40 (4.7)| 43 (6.2)
- 9| 42 (5.5)| 36 (2.2)| 39 (3.9)
- Before You Begin (Mechanical Controls)
- Probe Installation
- Temperature Control Installation
- Relay Installation
- Troubleshooting
- Appendix
- Documents / Resources
Sollatek FCA23 Installation 845565
TRUE MANUFACTURING CO., INC.
Technical Service Instruction
FCA23 Sollatek Temp Control
STOP! All work detailed in these instructions must be done by a qualified technician.
Subject: Sollatek FCA23 Installation
Date: June 23, 2023
Models / Parts Affected: Electronic Temperature Control Kits P#848325
(Universal) & P#848326 (Wine/Chocolate)
Voltages: All Voltages
Overview
The Sollatek FCA 23 holds an average product temperatures of 32-40°F (0-4.4°C)
for universal applications and 39-71°F (3.9-21.7°C) for wine/ chocolate
applications. The electronic temperature control requires a neutral line to
complete the circuit.
NOTE: Always install the provided relay. Some applications may have an
existing relay; in these cases replace the existing relay.
WARNING! Electrical shock or burn hazard. Powering off an electronic
control does not remove power from all components.
Unplug the unit or turn off the power supply before proceeding.
WARNING! Sharp edges. Take care when installing, cleaning, servicing, and maintaining the equipment.
Kit Components
NOTE: Required components and quantities vary by model
Universal Control Kit Components
- (1) Electronic Temperature Control
- (1) Black Probe (thermostat)
- (1) White Probe (defrost)
- (1) White/Blue Wire with 1/4” Blue Spade Connector
- (1) Black Wire (bare)
- (3) 1/4” Spade Connectors
- (2) 2-Way Lever Connectors
- (1) 3-Way Lever Connector
- (1) 5-Way Lever Connector
- (6) Small Cable Ties
- (2) 1/4” P-Clips
- (4) 3/16” Black P-Clips
- (6) 8-18 x 1/2” Hex Head Screws
- (2) 6-20 x 5/16” Phillips Hex Head Screws
- (2) M4 x 10 Pan Head Phillips Screws
Universal Control Relay Kit Components
- (1) Temperature Control Relay
- (1) Black Wire with 1/4” Blue Spade Connector
- (1) Brown/Red Wire with 1/4” Blue Spade Connector
- (1) Brown Wire with 3/16” Red Spade Connector
- (1) White Wire with 3/16” Red Spade Connector
- (4) 2-Way Lever Connectors
- (1) 3-Way Lever Connector
- (2) 5-Way Lever Connectors
- (2) M4 x 12 mm Hex Head Screws
Wine/Chocolate Control Kit Components
- (1) Electronic Temperature Control
- (1) Black Probe (thermostat)
- (1) White Probe (defrost)
- (1) White/Blue Wire with 1/4” Blue Spade Connector
- (1) Black Wire (bare)
- (3) 1/4” Spade Connectors
- (2) 2-Way Lever Connectors
- (1) 3-Way Lever Connector
- (1) 5-Way Lever Connector
- (6) Small Cable Ties
- (2) 1/4” P-Clips
- (4) 3/16” Black P-Clips
- (6) 8-18 x 1/2” Hex Head Screws
- (2) 6-20 x 5/16” Phillips Hex Head Screws
- (1) Hazardous Food Warning Label
- (2) M4 x 10 Pan Head Phillips Screws
Wine/Chocolate Control Relay Kit Components
- (1) Temperature Control Relay
- (1) Black Wire with 1/4” Blue Spade Connector
- (1) Brown/Red Wire with 1/4” Blue Spade Connector
- (1) Brown Wire with 3/16” Red Spade Connector
- (1) White Wire with 3/16” Red Spade Connector
- (4) 2-Way Lever Connectors
- (1) 3-Way Lever Connector
- (2) 5-Way Lever Connectors
- (2) M4 x 12 mm Hex Head Screws
Required Tools
Required tools include (but may not be limited to) the following:
- Gloves
- Wire Cutters/Crimpers/Strippers
- Phillips Screwdriver or Bit Driver
- Flat Blade Screwdriver
- 1/4” Hex Head Driver
- Needle Nose Pliers
- Volt Meter
- Adjustable Wrench
- Tape
- Marking Utensil
- Drill
NOTE: Required equipment varies by model
Control Specifications
Fig. 1. The mounting holes measure 2-3/16” (55.6 mm) center-to-center. The replacement control mounts in the same location as the existing control.
Table 1. Electrical Specifications
Voltage| 75-240 V AC
Frequency| 50/60 Hz
Control Operation
The electronic temperature control…
- Cycles the compressor on and off based on the return air temperature. See table 2 and table 3.
- Automatically defrosts every four (4) hours of compressor run time.
- Initiates an additional defrost if the evaporator coil temperature drops to 9°F (12.8°C).
- Defrosts between 4 min minimum and 40 min maximum, or until the evaporator coil measures 38°F (3.4°C).
Table 2. Universal Control Setting Temperature Chart
Control Setting| Cut-In| Cut-Out| Avg. Product Temperature
°F (°C)| °F (°C)| °F (°C)
1| 43 (6.1)| 37 (2.7)| 40 (4.4)
2| 42 (5.5)| 36 (2.2)| 39 (3.9)
3| 41 (5.0)| 35 (1.6)| 38 (3.3)
4| 40 (4.4)| 34 (1.1)| 37 (2.8)
5| 39 (3.8)| 33 (0.5)| 36 (2.2)
6| 38 (3.3)| 32 (0.0)| 35 (1.7)
7| 37 (2.7)| 31 (-0.6)| 34 (1.1)
8| 36 (2.2)| 30 (-1.2)| 33 (0.5)
9| 35 (1.6)| 29 (-1.7)| 32 (0.0)
Table 3. Wine/Chocolate Control Setting Temperature Chart
Control Setting| Cut-In| Cut-Out| Avg. Product Temperature
°F (°C)| °F (°C)| °F (°C)
1| 74 (23.3)| 68 (20.0)| 71 (21.7)
2| 70 (21.1)| 64 (17.8)| 67 (19.5)
3| 66 (18.9)| 60 (15.6)| 63 (17.3)
4| 62 (16.6)| 56 (13.3)| 59 (15.0)
5| 58 (14.4)| 52 (11.1)| 55 (12.8)
6| 54 (12.2)| 48 (8.9)| 51 (10.6)
7| 50 (10.0)| 44 (6.7)| 47 (8.4)
8| 46 (7.7)| 40 (4.7)| 43 (6.2)
9| 42 (5.5)| 36 (2.2)| 39 (3.9)
Hazardous Food Warning Label (Wine/Chocolate Kit Only)
If adjusting the set point to 41°F (5°C) or greater, place the provided
hazardous food warning label below the serial label inside the cabinet as
shown in fig. 1. This label notifies users the cabinet has been set to
maintain a temperature above outside NSF perishable food storage guidelines.
Fig.
2. Hazardous food warning label intended location.
Before You Begin (Mechanical Controls)
If converting a mechanical control to an electronic control, see the following information. If replacing an electronic control, procede to “Temperature Control Installation” (pg. 6).
Determine Airflow Direction
Determine the airflow direction through the evaporator coil. See figs. 1 and
2. Airflow direction dictates probe placement. the black (thermostat) probe
will be placed in the return air stream. Fig. 1. The fan motor pushes air through the coil.
Place probe on indicated side. Items not to scale. Fig. 2. The fan motor pulls air through
the coil. Place probe on indicated side.
Items not to scale.
Determine Voltage Wire & Label Wires
-
At the temperature control, with a volt meter, locate the following wires and mark them as directed below:
• Line in/Line; Label wire LINE.
• Line out/Load; Label wire LOAD. -
Remove the mechanical control.
4-Wire Fan Motors
Fig. 3. Fan motor sticker will be on the evaporator housing.
TRUE T-Series or GDM ONLY
Check the unit for a 4-wire evaporator fan motor or a sticker (see fig.
3) on the evaporator housing. If present, rewire the fan motor before
proceeding. See “Rewiring the 4-Wire EBM Fan Motor” (pg. 15).
Probe Installation
Mechanical Control Probe Installation Fig. 1. Use a p-clip to secure the probe to the appliance or a cable tie to attach it to a bracket or wire.
-
Unplug the unit or remove the power supply.
-
Remove the existing probes.
-
With the provided mounting hardware (see fig. 1) install the provided black (thermostat) probe in the return air stream (see pg..
NOTE: Be sure the black probe does not contact a metal surface; otherwise, it will read surface temperature, instead of return air temperature. -
On any airflow side of the evaporator coil, locate the horizontal and vertical centers. See fig. 2. Then, push the white (defrost) probe into the center.
NOTE: Insert the probe flush with the coil fins. Tuck the coil fins around the probe to help secure it. See fig. 3. -
Run the probe wires to the temperature control installation location.
-
With the provided 3/16” p-clips or cable ties, secure the probe wires to prevent contact with moving parts.
-
Proceed to “Temperature Control Installation” (pg. 6).
Fig. 2. Install the white probe tip in the center of the evaporator coil’s airflow side. Fig. 3. Pinch the evaporator coil fins around the probe.
Electronic Control Probe Installation
-
Unplug the unit or remove the power supply.
-
Remove the existing probes.
-
Install the replacement probes in the original probe locations:
• Black (thermostat) in the return air stream (see pg. 4).
• White (defrost) in the center of an airflow side of the coil (see fig. 2)
Run the probe wires to the temperature control installation location. -
With the provided 3/16” p-clips or cable ties, secure the probe wires to prevent contact with moving parts.
-
Proceed to “Temperature Control Installation” (pg. 6).
Temperature Control Installation
- Connect the Probes to the Control
Connect the probes to the replacement temperature control as follows (see fig. 2):
• Black (thermostat) probe to PRB1 terminal
• White (defrost) probe to PRB2 terminal
NOTE: Confirm probe connections before proceeding. Reversing the wires will cause incorrect operation.
Fig. 2. Probe terminal locations.
2a. Direct Replacement
- Unplug the appliance or remove the power supply.
- Replace the control components and probes like-for-like.
- Install the relay. See “Relay Installation” (pg. 8).
Fig. 3. Replacement temperature control terminals. Fig. 4. DO NOT overtighten the screws when installing the control.
2b. Replace a Mechanical Control
-
With a provided lever connector, splice in a neutral wire from any component (such as the evaporator fan motor or electrical box) to connect to the replacement control.
-
Connect the marked wires (from pg. 4) to the replacement temperature control as follows (see fig. 3):
• LINE wire to Live In terminal
• LOAD wire to Comp terminal
• Neutral wire to Neutral terminal
NOTE: To cycle the evaporator fan motor on and off with the compressor, connect the wire powering the evaporator fan motor to Aux1. See fig. 3. -
If Aux1 is unused, cover it with the 1/4” female spade connector.
-
With the provided Phillips hex head screws, install the control in the appliance. See fig. 4.
NOTE: DO NOT overtighten the screws. -
Align the flattened edge of the control knob’s slot with the temperature control’s shaft. Push the knob onto the shaft.
-
Fully turn the knob counterclockwise and mark #0.
-
Turn the knob clockwise until your mark aligns with #5 before powering the appliance.
NOTE: Powering the appliance when the control is set to #9 or #0 initiates test mode. To stop the test, remove power for five (5) min to reset the control. Then, set the control to #5 before reapplying power. -
Install the relay. See “Relay Installation” (pg. 8).
2c. Replace a Sollatek FCA22 Fig. 5. Existing wiring configuration (A) and the replacement wiring configuration (B).
-
Label the existing temperature control’s remaining wire connections.
-
Remove the existing temperature control.
-
Connect the labeled wires to the replacement temperature control as follows (see fig. 5):
• Neutral wire to Neutral terminal
• Live in wire to Live In terminal
• Comp wire to Comp terminal
• Aux wire to Aux1 terminal
NOTE: If Aux1 is unused, cover it with the 1/4” female spade connector. -
With the provided Phillips hex head screws, install the control in the appliance. See fig. 4.
NOTE: DO NOT overtighten the screws. -
Align the flattened edge of the control knob’s slot with the temperature control’s shaft. Push the knob onto the shaft.
-
Fully turn the knob counterclockwise and mark #0.
-
Turn the knob clockwise until your mark aligns with #5 before powering the appliance.
NOTE: Powering the appliance when the control is set to #9 or #0 initiates test mode. To stop the test, remove power for five (5) min to reset the control. Then, set the control to #5 before reapplying power. -
Install the relay. See “Relay Installation” (pg. 8).
2d. Replace a TEC22
Fig. 6. Existing wiring configuration (A) and the replacement wiring configuration (B).
-
Label the existing temperature control’s remaining wire connections.
-
Remove the existing temperature control.
-
Connect the labeled wires to the replacement temperature control as follows (see fig. 6):
• N wire to Neutral terminal
• L wire to Live In terminal
• COMP wire to Comp terminal
• FAN wire to Aux1 terminal
NOTE: If Aux1 is unused, cover it with the 1/4” female spade connector. -
With the provided Phillips hex head screws, install the control in the appliance. See fig. 4.
NOTE: DO NOT overtighten the screws. -
Align the flattened edge of the control knob’s slot with the temperature control’s shaft. Push the knob onto the shaft.
-
Fully turn the knob counterclockwise and mark #0.
-
Turn the knob clockwise until your mark aligns with #5 before powering the appliance.
NOTE: Powering the appliance when the control is set to #9 or #0 initiates test mode. To stop the test, remove power for five (5) min to reset the control. Then, set the control to #5 before reapplying power. -
Install the relay. See “Relay Installation” (pg. 8).
Relay Installation
-
Connect the Provided Wires to the Provided Relay
1. Connect the provided wires to the provided relay as follows (see fig. 1):
• White Wire with 3/16” Red Spade Connector to Upper Left Terminal
• Brown Wire with 3/16” Red Spade Connector to Lower Left Terminal
• Black Wire with 1/4” Blue Spade Connector to COM Terminal
• Brown/Red Wire with 1/4” Blue Spade Connector to NO Terminal -
Proceed to the appropriate section.
Fig. 1. Provided wire locations on the provided relay terminals.
2a. Replace the Existing Relay Fig. 2. Existing relay terminal configuration.
-
With provided lever connectors, connect the wires from the existing relay terminals (see fig. 2) to the provided relay wires as follows:
• Terminal #4 Wire to Black Relay Wire
• Terminal #6 Wire to Brown/Red Relay Wire
• Terminal #0 Wire to Brown Relay Wire
• Terminal #1 Wire to White Relay Wire -
Remove the existing relay.
-
Install the replacement relay in the original relay location.
-
Restore power and verify operation.
2b. Add the Provided Relay (Appliances with an Electrical Box)
-
Access and open the electrical box.
-
With the provided lever connectors, connect the provided relay to the appliance as follows (see fig. 3).
• Black Relay Wire to Line Voltage from Main Power Cord
• Brown/Red Relay Wire to Compressor/Condenser Fan Motor
• Brown Relay Wire to Temperature Control Comp wire
• White Relay Wire to Neutral from Main Power Cord -
Install the relay in the electrical box.
-
Restore power and verify operation.
Fig. 3. Relay and temperature control wiring diagram.
2c. Add the Provided Relay (Appliances without an Electrical Box)
Appliances without electrical boxes will have one of three terminal blocks.
A. Black 4-Wire Terminal Block
-
Access the terminal block.
-
Cut the terminal block wires going to the temperature control. See fig. 4, “Cut here”.
-
With the provided lever connectors, connect the relay wires to the terminal block wires as follows (see fig. 4):
• Black Relay Wire to #3 and #4
• Brown/Red Relay Wire to #1
• Brown Relay Wire to #2
• White Relay Wire to #5 (neutral for temperature control) -
With the provided hardware, install the relay.
-
Restore power and verify operation.
Fig. 4. Black 4-wire terminal block diagram.
B. White 6-Wire Terminal Block
-
Access the terminal block.
-
Cut the terminal block wires going to the temperature control. See fig. 5, “Cut here”.
-
With the provided lever connectors, connect the relay wires to the terminal block wires as follows (see fig. 5):
• Black Relay Wire to #3 and #4
• Brown/Red Relay Wire to #1
• Brown Relay Wire to #2
• White Relay Wire to #5 (neutral for temperature control) -
With the provided hardware, install the relay.
-
Restore power and verify operation.
Fig. 5. White 6-wire terminal block diagram.
C. Black/Blue 6-Wire Terminal Block
-
Access the terminal block.
-
Cut the terminal block wires going to the temperature control. See fig. 6, “Cut here”.
-
With the provided lever connectors, connect the relay wires to the terminal block wires as follows (see fig. 6):
• Black Relay Wire to #3 and #4
• Brown/Red Relay Wire to #1
• Brown Relay Wire to #2
• White Relay Wire to #5 (neutral for temperature control) -
With the provided hardware, install the relay.
-
Restore power and verify operation.
Fig. 6. Black/Blue 6-wire terminal block diagram.
Troubleshooting
Basic Troubleshooting Fig. 1. Indicator light locations.
In addition to reading the control indicator light codes [see “Control
Indicator Light Codes0
Table” (pg. 13)], note the potential solutions below:
- Check the terminal connections:
- If the power wires (Live In and Comp) are reversed, the control indicator lights will not light and the compressor will not start. See fig. 1. for light locations.
- If the probe wires are reversed, the control will not cycle correctly.
- Check if the black probe is touching metal. If so, the probe is reading surface temperature instead of return air temperature.
Table 1. Control Indicator Light Codes
Red LED | Yellow LED | Green LED | Meaning |
---|---|---|---|
ON | OFF | ON | Defrost mode |
Flashing | ON | Flashing | Mini-defrost mode |
Cycling | OFF | Cycling | Pre-defrost mode |
Flashing | OFF | Flashing | Drip down mode |
OFF | ON | ON | Post-defrost recovery mode |
OFF1 | One (1) Blink2 | OFF | Probe #1 faulty; good voltage |
OFF1 | Two (2) Blinks2 | OFF | Probe #2 faulty; good voltage |
ON | One (1) Blink2 | OFF | Probe #1 faulty; bad voltage |
ON | Two (2) Blinks2 | OFF | Probe #2 faulty; bad voltage |
Cycling | Cycling | Cycling | Knob set to #0 (off position) |
OFF1 | OFF | ON | On mode |
OFF1 | Flashing | ON | On mode, but compressor is off due to door switch |
operation
ON| OFF| OFF| Bad voltage; cooling demand
Flashing| OFF| OFF| Bad voltage; temperature satisfied
OFF| ON| OFF| Wait mode; cooling demand
OFF| Flashing| OFF| Wait mode; temperature satisfied, protection delay not
over
OFF| OFF| Flashing| Wait mode; temperature satisfied, protection delay over
Flashing| Flashing| Flashing| Test mode
Cycling3| Cycling3| OFF| Bad frequency detection
Flashing⁴| Flashing⁴| Flashing⁴| Internal power supply failure
NOTE: All cycling and flashing is for one (1) sec duration unless
otherwise specified
1: LED comes on momentariliy during under voltage and over voltage blind time
2: Every two (2) sec
3: Every half (0.5) sec
4: Five (5) times a sec
Table 2. Temperature-to-Resitance
Table 2 shows the expected cut-in/cut/out range of the Sollatek FCA23
electronic temperature control.
NOTE: This information is for diagnostic purposes only.
Temperature | Resistance | Temperature | Resistance |
---|---|---|---|
°C (°F) | k-Ohms | °C (°F) | k-Ohms |
-10 (14.0) | 548.267 | 25 (77.0) | 100.000 |
-9 (15.8) | 519.821 | 26 (78.8) | 95.692 |
-8 (17.6) | 492.994 | 27 (80.6) | 91.592 |
-7 (19.4) | 467.688 | 28 (82.4) | 87.687 |
-6 (21.2) | 443.810 | 29 (84.2) | 83.969 |
-5 (23.0) | 421.271 | 30 (86.0) | 90.427 |
-4 (24.8) | 399.992 | 31 (87.8) | 77.051 |
-3 (26.6) | 379.896 | 32 (86.6) | 93.835 |
-2 (28.4) | 360.911 | 33 (91.4) | 70.768 |
-1 (30.2) | 342.971 | 34 (93.2) | 67.844 |
0 (32.0) | 326.015 | 35 (95.0) | 65.055 |
1 (33.8) | 309.982 | 36 (96.8) | 62.395 |
2 (35.6) | 294.819 | 37 (98.6) | 59.857 |
3 (37.4) | 280.475 | 38 (100.4) | 57.434 |
5 (41.0) | 254.054 | 39 (102.2) | 55.122 |
6 (42.8) | 241.890 | 40 (104.0) | 52.914 |
7 (44.6) | 230.369 | 41 (105.8) | 50.805 |
9 (48.2) | 209.115 | 42 (107.6) | 48.790 |
10 (50.0) | 199.314 | 43 (109.4) | 46.866 |
11 (51.8) | 190.021 | 44 (111.2) | 45.026 |
12 (53.6) | 181.209 | 45 (113.0) | 43.268 |
13 (55.4) | 172.849 | 46 (114.8) | 41.587 |
14 (57.2) | 164.918 | 47 (116.6) | 39.980 |
15 (59.0) | 157.391 | 48 (118.4) | 38.443 |
16 (60.8) | 150.245 | 49 (120.2) | 36.972 |
17 (62.6) | 143.590 | 50 (122.0) | 35.564 |
18 (64.4) | 197.014 | 60 (140.0) | 24.386 |
19 (66.2) | 130.891 | 70 (158.8) | 17.035 |
20 (68.0) | 125.073 | 80 (176.0) | 12.110 |
21 (69.8) | 119.542 | 90 (194.0) | 8.750 |
22 (71.6) | 114.283 | 100 (212.0) | 6.419 |
23 (73.4) | 109.283 | ||
24 (75.2) | 104.526 |
Appendix
Rewiring the 4-Wire EBM Fan Motor
If the evaporator fan motor cycles or is a 4-wire motor, it must be rewired to
operate correctly with the new electronic temperature control. See the
procedure below.
- Locate the black EBM wire sleeve containing black, brown, blue, and green/yellow wires. See fig. 1.
- Cut the black and brown fan motor wires 1” (25.4 mm) from their respective connectors. See fig. 2.
- With a provided 2-way lever connector, cap the black wire left attached to the original connector.
- With a provided 2-way lever connector, cap the brown wire left attached to the original connector.
- Strip 7/16” (11.1 mm) of insulation from the fan motor side of the black and brown wires.
- With a provided 3-way lever connector, connect the stripped black and brown fan motor wires to the provided bare black wire.
- Crimp a provided spade connector to the bare black wire.
- Connect the black wire to the temperature control Aux1 terminal.See fig. 3.
Fig. 1. The four fan motor wires and wire sleeve. Fig. 2. EBM fan motor original black and brown connections. Fig. 3. Aux1 terminal of the replacement electronic temperature control.
Control Knob Cover Installation
If the control knob cover is present, install the knob cover as described below. Fig. 4. Cut the threads in the control screwholes.
- With the provided Phillips hex head screws, cut threads in the control screwholes. See fig. 4.
- install the knob and knob cover per fig. 5. Use the provided pan head Phillips screws.
Fig. 5. Exploded view of control knob and control knob cover installation.
Questions or Concerns
For more information, please contact our Technical Service team. See contact
information below.
Contact Us
North America – USA, Canada & Caribbean
Warranty Phone: +1 855 878 9277
Warranty Fax: +1 636 980 8510
Warranty Email:
WarrantyInquiries@TrueMfg.com
Technical Phone: +1 855 372 1368
Technical Email: Service@TrueMfg.com
7:00am-6:00pm CST Monday-Friday;
8:00am-12:00pm Saturday
European Union & Commonwealth of Independent States
Phone: +49 (0) 7622 6883 0
Service-EMEA@TrueMfg.com
8:00am-5:00pm M-F
UK, Ireland, Middle East, Africa & India
Phone: +44 (0) 800 783 2049
Service-EMEA@TrueMfg.com
8:30am-5:00pm M-F
Latin America
Phone: +52 555 804 6343/44
ServiceLatAm@TrueMfg.com
9:00am-5:30pm M-F
Mexico
Phone: +52 555 804 6343/44
Service-MexicoCity@TrueMfg.com
9:00am-5:30pm M-F
Australia
Phone: +61 2 9618 9999
Service-Aus@TrueMfg.com
8:30am-5:00pm M-F
06/23/2023
EA | E413
TEC_WI_1407 | REV. C
BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold
Ones”
Documents / Resources
| true
FCA23 Sollatek Temp
Control
[pdf] Installation Guide