  • The switching component with one/two output relays is used to control appliances and lights. Switches/buttons connected to the wiring can be used for control.
  • They can be combined with Detectors, Controllers or iNELS RF Control System Components.
  • The BOX version offers installation directly in the installation box, ceiling or cover of the controlled appliance. Easy installation thanks to screwless terminals.
  • It allows the connection of switched loads with a total sum of 8 A (2,000 W).
  • Functions: for RFSAI 61B-SL and RFSAI 62B-SL – pushbutton, impulse relay and time functions of delayed start or return with time setting 2 s-60 min. Any function can be assigned to each output relay. For RFSAI-11B-SL, the button has a fixed function – ON / OFF.
  •  The external button is assigned in the same way as the wireless one.
  •  Each of the outputs can be controlled by up to 12/12 channels (1-channel represents one button on the controller). Up to 25 channels for RFSAI-61B-SL and RFSAI-11B-SL.
  •  The programming button on the component also serves as a manual output control.
  •  Possibility to set the output status memory in case of failure and subsequent power recovery.
  • The elements of the repeater can be set for the components via the RFAF / USB service device, PC, application.
  • Range up to 200 m (outdoors), in case of insufficient signal between the controller and the device, use the RFRP-20 signal repeater or component with the RFIO2 protocol that support this function.
  •  Communication with bidirectional RFIO2 protocol.
  • The contact material of the AgSnO2 relay enables switching of light ballasts.

Assembly

mounting in an installation box  (even under the existing button / switch)
inELS RFSAI-62B-SL Switch Unit productmounting into the light coverinELS RFSAI-62B-SL Switch Unit productceiling mountedinELS RFSAI-62B-SL Switch Unit 03

Connection

RFSAI-61B-SL

RFSAI-62B-SL
Screw less terminals inELS RFSAI-62B-SL Switch Unit
03

**Radio frequency signal penetration through various construction

materials**

inELS RFSAI-62B-SL Switch Unit 54

inELS RFSAI-62B-SL Switch Unit 08| inELS
RFSAI-62B-SL Switch Unit 08| |


| **
---|---|---|---|---
60 – 90 %| 80 – 95 %| 20 – 60 %| 0 – 10 %| 80- 90 %
brick walls| wooden structures with plaster boards| reinforced concrete| metal partitions| **
common glass

Indication, manual control

inELS RFSAI-62B-SL Switch Unit 12

  1. LED / PROG button
    •  LED green V1 – device status indication for output 1
    •  LED red V2 – device status indication for output 2. Indicators of memory function:
    • On – LED blinks x 3.
    • Off – The LED lights up once for a long time.
    •  Manual control is performed by pressing the PROG button for<1s.
    •  Programming is performed by pressing the PROG button for 3-5s.
  2.  Terminal block – connection for external button
  3. Terminal block – connecting the neutral conductor
  4. Terminal block – load connection with the sum of the total current 8A (eg V1=6A, V2=2A)
  5. Terminal block for connecting the phase conductor

In the programming and operating mode, the LED on the component lights up at the same time each time the button is pressed – this indicates the incoming command.

  • RFSAI-61B-SL: one output contact, status indication by red LED
    inELS RFSAI-62B-SL Switch Unit 12

  • Use a suitable tool (paper clip, screwdriver) to push on the control pin. The batteries are raised and the programming button is released.
    inELS RFSAI-62B-SL Switch Unit 12

  • After removing the control flaps, the programming button is accessible. inELS RFSAI-62B-SL Switch Unit 12

  • The programming button is operated with a suitable thin tool.
    inELS RFSAI-62B-SL Switch Unit 12

Compatibility inELS RFSAI-62B-SL Switch Unit 12The device can be combined with all system components, controls and devices of iNELS RF Control and iNELS RF Control2. The detector can be assigned an iNELS RF Control2 (RFIO2) communication protocol.
Channel selection
Channel selection (RFSAI-62B-SL) is done by pressing the PROG buttons for 1-3s. RFSAI-61B-SL: press for more than 1 second. After button release, LED is flashing indicating the output channel: red (1) or green (2). All other signals are indicated by corresponding color of LED for each channel.

Functions and programming with RF transmitters

Function button
Description of button
The output contact will be closed by pressing the button and opened by releasing the button. For the correct execution of individual commands (press = closing / releasing the button = opening), the time delay between these commands must be a min of . 1s (press – delay 1s – release).
Programming
inELS RFSAI-62B-SL Switch Unit 12Press of programming button on receiver RFSAI-62B for 3-5 s (RFSAI-61B-SL: press for more than 1 s) will activate receiver RFSAI-62B into programming mode. LED is flashing in 1s interval.
inELS RFSAI-62B-SL Switch Unit 12
Select and press one button on wireless switch, to this but-ton will be assigned function Button.
inELS RFSAI-62B-SL Switch Unit 23Press of programming button on receiver RFSAI-62B shorter then 1 second will finish programming mode. The LED lights up according to the pre-set memory function.
Function switch on
Description of switch on
inELS RFSAI-62B-SL Switch Unit 24The output contact will be closed by pressing the button.
Programming
Press of programming button on receiver RFSAI-62B for 3-5 s (RF-SAI-11B-SL: press for more than 1s) will activate receiver RFSAI-62B into programming mode. LED is fl ashing in 1s interval.
inELS RFSAI-62B-SL Switch Unit 26Two presses of your selected button on the RF transmitter assigns the function switch on (must be a lapse of 1s between individual presses).
Press of programming button on receiver RFSAI-62B shorter then 1 second will finish programming mode. The LED lights up according to the pre-set memory function.
Function switch off
Description of switch off
The output contact will be opened by pressing the button.
Programming
inELS RFSAI-62B-SL Switch Unit 26 Press of programming button on receiver RFSAI-62B for 3-5 s (RF-SAI-61B-SL: press for more than 1 s) will activate receiver RFSAI-62B into programming mode. LED is fl ashing in 1s interval.
inELS RFSAI-62B-SL Switch Unit 26Three presses of your selected button on the RF transmitter assigns the function switch off (must be a lapse of 1s between individual presses).
inELS RFSAI-62B-SL Switch Unit 31 Press of programming button on receiver RFSAI-62B shorter then 1 second will finish programming mode. The LED lights up according to the pre-set memory function.
Function impulse relay
Description of impulse relay
The output contact will be switched to the opposite position by each press of the button. If the contact was closed, it will be opened and vice versa.
Programming
inELS RFSAI-62B-SL Switch Unit 32 Press of programming button on receiver RFSAI-62B for 3-5 s (RFSAI-61B-SL: press for more than 1 s) will activate receiver RFSAI-62B into programming mode. LED is fl ashing in 1s interval.
inELS RFSAI-62B-SL Switch Unit 32Four presses of your selected button on the RF transmitter as-signs the function impulse relay (must be a lapse of 1s between individual presses).
inELS RFSAI-62B-SL Switch Unit 32Press of programming button on receiver RFSAI-62B shorter then 1 second will finish programming mode. The LED lights up according to the pre-set memory function.
Function delayed off
Description of delayed off
The output contact will be closed by pressing the button and opened after the set time interval has elapsed.
Programming
Press of programming button on receiver RFSAI-62B for 3-5 s (RF-SAI-61B-SL: press for more than 1 s) will activate receiver RFSAI-62B into programming mode. LED is fl ashing in 1s interval.
Assignment of the delayed off function is performed by fi ve presses of the selected button on the RF transmitter (must be a lapse of 1s between individual presses).
Press of programming button longer then 5 seconds, will activate actuator into timing mode. LED flashs 2x in each 1s interval. Upon releasing the button, the delayed return time starts counting.
inELS RFSAI-62B-SL Switch Unit 38
After the desired time has elapsed (range of 2s…60min), the timing mode ends by pressing the button on the RF transmitter, to which the delayed return function is assigned. This stores the set time interval into the actuator memory.
Press of programming button on receiver RFSAI-62B shorter then 1 second will fi nish pro-gramming mode. The LED lights up according to the pre-set memory function.
Function delayed on /
Description of delayed on /
The output contact will be opened by pressing the button and closed after the set time interval has elapsed.
Programming /
Press of programming button on receiver RFSAI-62B for 3-5 s (RF-SAI-61B-SL: press for more than 1s) will activate receiver RFSAI-62B into programming mode. LED is fl ashing in 1s interval.
inELS RFSAI-62B-SL Switch Unit 45Assignment of the delayed on function is performed by six presses of the selected button on the RF transmitter (must be a lapse of 1s between individual presses).
Press of programming button longer then 5 seconds, will activate actuator into timing mode. LED flashs 2x in each 1s interval. Upon releasing the button, the delayed return time starts counting.
inELS RFSAI-62B-SL Switch Unit 46
After the desired time has elapsed (range of 2s…60min), the timing mode ends by pressing the button on the RF transmitter, to which the delayed return function is assigned. This stores the set time interval into the actuator memory.
Press of programming button on receiver RFSAI-62B shorter then 1 second will finish programming mode. The LED lights up according to the pre-set memory function.

Programming with RF control units

inELS RFSAI-62B-SL Switch Unit logo 50Addresses listed on the front side of the actuator are used for programming and controlling the actuator and individual RF channels by control units.
Deleting one position of the transmitter
By pressing the programming button on the actuator for 8 seconds (RFSAI-61B- SL: press for 5 second), deletion of one transmitter activates. LED flashs 4x in each 1s interval. Pressing the required button on the transmitter deletes it from the actuator’s memory. To confirm deletion, the LED will confirm with a fl ash long and the component returns to the operating mode. The memory status is not indicated. Deletion does not affect the pre-set memory function.
Deleting the entire memory
inELS RFSAI-62B-SL Switch Unit 52 By pressing the programming button on the actuator for 11 seconds (RFSAI-61B-SL: press for more than 8 second), deletion occurs of the actuator’s entire memory. LED flashs 4x in each 1s interval. The actuator goes into the programming mode, the LED fl ashes in 0.5s intervals (max. 4 min.). You can return to the operating mode by pressing the Prog button for less than 1s. The LED lights up according to the pre-set memory function and the component returns to the operating mode. Deletion does not affect the pre-set memory function.
Selecting the memory function
Press of programming button on receiver RFSAI-62B for 3-5 second (RFSAI-61B- SL: press for 1 second) will activate receiver RFSAI-62B into programming mode. LED is flashing in 1s interval.
Pressing the programming button on the RFSAI-62B receiver for less than 1 second will finish the programming mode, this will re-verse the memory function. The LED lights up according to the current pre-set memory function. The set memory function is saved. Every other change is made in the same way.

  •  Memory function on:
    • For functions 1-4, these are used to store the last state of the relay output before the supply voltage drops, the change of state of the output to the memory is recorded 15 seconds after the change.
    • For functions 5-6, the target state of the relay is immediately entered into the memory after the delay, after re-connecting the power, the relay is set to the target state.
  •  Memory function off:

When the power supply is reconnected, the relay remains off.
The external button RFSAI-62B-SL is programmed in the same way as for wireless. RFSAI-11B-SL it is not programmed, it has a fixed function.

Technical parameters

RFSAI-11B-SL
RFSAI-61B-SL
RFSAI-62B-SL

Supply voltage: Napájecí napětí: 230 V AC
Supply voltage frequency: Frekvence napájecího napětí: 50-60 Hz
Apparent input: Příkon zdánlivý: 7 VA / cos φ = 0.1
Dissipated power: Příkon ztrátový: 0.7 W
Supply voltage tolerance: Tolerance napájecího napětí: +10 %; -15 %
Output Výstup
Number of contacts: Počet kontaktů: 1x switching / 1x spínací

2xspínací
Rated current:| Jmenovitý proud:| 8 A / AC1
Switching power:| Spínaný výkon:| 2000 VA / AC1
Peak current:| Špičkový proud:| 10 A / <3 s
Switching voltage:| Spínané napětí:| 250 V AC1
Mechanical service life:| Mechanická životnost:| 1×107
Electrical service life (AC1):| Elektrická životnost (AC1):| 1×105
Control| Ovládán í|
Wireless:| Bezdrátově:| 25-channels/ 25 kanálů                               2 x 12-channels/ 2 x 12 kanály
Number of functions:| Počet funkcí:| 1| 6| 6
Communication protocol:| Komunikační protokol:| RFIO2
Frequency:| Frekvence:| 866–922 MHz (for more information see p. 74)/ 866–922 MHz (viz str. 74)
Repeater function:| Funkce repeater:| yes/ ano
Manual control:| Manuální ovládání:| button PROG (ON/OFF)/ tlačítko PROG (ON/OFF)
External button / switch: Range:| Externím tlačítkem:| yes/ ano
Other data| Dosah:| in open space up to 200 m/ na volném prostranství až 200 m
Operating temperature:| Další údaje|
Operating position:| Pracovní teplota:| -15 až + 50 °C
Operating position:| Pracovní poloha:| any/ libovolná
Mounting:| Upevnění:| free at lead-in wires/ volné na přívodních vodičích
Protection:| Krytí:| IP40
Overvoltage category:| Kategorie přepětí:| III.
Contamination degree:| Stupeň znečištění:| 2
Connection:| Připojení:| screwless terminals/ bezšroubové svorky
Connecting conductor:| Průřez připojovacích vodičů (mm2)| 0.2-1.5 mm2 solid/flexible/ 0.2-1.5 mm2 pevný/pružný
Dimensions:| Rozměr:| 43 x 44 x 22 mm
Weight:| Hmotnost:| 31g| 45 g
Related standards:| Související normy:| EN 60730, EN 63044, EN 300 220, EN 301 489

  • Control button input is at the supply voltage potential.

Attention:
When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units. Between the individual commands must be an interval of at least 1s.
Warning
Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing. Installation and connection can be carried out only by a person with adequate professional qualification upon under- standing this instruction manual and functions of the device, and while observing all valid regulations. Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing observe safety regulations, norms, directives and professional, and export regulations for working with electrical devices. Do not touch parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe correct location of RF components in a building where the installation is taking place. RF Control is designated only for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. The must not be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is then impossible. RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an obstruction, interfered, battery of the transceiver can get fl at etc. and thus disable remote control.
ELKO EP declares that the RFSG type of equipment complies with Directives 2014/53/EU, 2011/65/EU, 2015/863/EU and 2014/35/EU. The full EU Declaration of Conformity is at: https://www.elkoep.com/wireless-contact-converter-230v —rfsg-1m
ELKO EP, s.r.o., Palackého 493, 769 01 Holešov, Všetuly, Czech Republic
Tel.: +420 573 514 211,
e-mail: elko@elkoep.com, www.elkoep.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals