BEGA 24713 Ceiling and Wall Luminaire Instruction Manual

June 13, 2024
BEGA

BEGA 24713 Ceiling and Wall Luminaire

DIMENSION

Instructions for use

Application
Unshielded ceiling and wall luminaire with high protection class. For a variety of interior and exterior lighting applications.

Product Description

  • Luminaire made of aluminium alloy,
  • aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Opal glass
  • 2 mounting holes ø 4.8 mm
  • Distance apart 170 mm
  • 2 screw cable glands with strain relief
  • for through-wiring power connecting cable
  • ø 7–12 mm
  • 1 screw cable gland closed at the factory with
  • a dummy plug
  • Connection terminal 2.5@
  • Earth conductor connection
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 170-280 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect
  • temperature-sensitive components
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • Impact strength IK02
  • Protection against mechanical
  • impacts < 0.2 joule
    • r – Safety mark
    • c – Conformity mark
  • Weight : 4.4 kg

This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 23 W
  • Luminaire connected wattage 25.6 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 35 °C

24 713 K3

  • Module designation LED-1248/830
  • Colour temperature 3000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 4130 lm
  • Luminaire luminous flux 3134 lm
  • Luminaire luminous efficiency 122,4 lm / W

24 713 K4

  • Module designation LED-1248/840
  • Colour temperature 4000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 4340 lm
  • Luminaire luminous flux 3293 lm
  • Luminaire luminous efficiency 128,6 lm / W

Lighting technology
Luminaire data for the DIALux lighting design program for outdoor lighting, street lighting and indoor lighting, as well as luminaire data in EULUMDAT and IES format are available on the BEGA website at www.bega.com.

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. Undo hexagon socket head screws (wrench size 3 mm) through the opening in the luminaire housing up to the stop and lift luminaire top. Disconnect the earth conductor connection from the plug connection. Disconnect plug-connection of the LED connecting cable. Lead the mains supply cable through the screw cable gland into the luminaire back housing. The installed black gasket insert is intended for cables ø < 10 mm. For cables ø 10-12 mm the enclosed grey gasket insert must be used. In case of through-wiring replace the factory installed dummy plug with the enclosed corresponding gasket insert. At the same time, use the enclosed synthetic cone-thrust collar between gasket insert and thrust screw (wrench size 22 mm) (see sketch).

Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface. Be sure to use the gasket rings supplied. Tighten screw cable gland. Make the earth conductor connection and the electrical connection. In order to guarantee the maximum servicelife of the electrical components, the enclosed desiccant pouch must be placed in the luminaire. Remove the desiccant pouch from the foil packaging and place it in the position markedby the red information label immediately before finally closing the luminaire. Make earth conductor connection between luminaire top and luminaire base.Connect the LED connection cable by means of a plug connector. Make sure that gasket is positioned correctly. Install the luminaire top, press-on and tighten screws evenly.

Cleaning Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high pressure cleaners.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the
  • LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced. Close the luminaire.

Spares

  • Spare glass 25 000 101
  • LED power supply unit DEV-0342/700
  • LED module 3000 K LED-1248/830
  • LED module 4000 K LED-1248/840
  • Gasket 83 002 062

CONTACT

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals