Trudian TD-RM01 Reader User Guide

June 13, 2024
Trudian

QUICK START GUIDE
Reader
Applicable Model: TD-RM01、TD-RM02、
TD-RM03、TD-RM04
Version : 1.0
Date : May 2023 Touching the future

Product Overview

Parameter:

Working voltage DC12V±10%
Swipe distance 0~4CM
Working current 80MA
Card reading type IC card
Communication mode Wegen 26 / Wegen 34
issuing mode management platform card issuing
Working temperature -20℃~70℃
Card capacity 1000
Relative humidity 20% ~ 93%
Open mode swipe card, APP, remote, password (optional)
 size 86 86 8MM
Installation method Control box

: hanging installation reading head
: 86 box embedded installation
.86 box requires a depth of 50MM inside

Wiegand Reader Installation diagram:

(a) Connect the signal line in the back of the read head device as shown in the figure below.

Trudian TD RM01 Reader

(b) Install the reading head device into the 86 box, (note that you need to use the embedded wall inside the depth of 50MM style 86 box), lock the screws to fix, as shown in the figure below.

Trudian TD RM01 Reader - head panel(c) Read the head panel and read the head body snap together, first from the upper snap down and then press the lower and bottom screw hole alignment; finally in the bottom of the anti-theft screw hole screwed on the countersunk head machine wire within the plum security screws fixed,as shown in the figure below.
Bottom
Locking plum security screw hole

Trudian TD RM01 Reader - screw hol

Wiring instruction

Operating mode selection

Wire color Function Description
Red Line DC12V
Blace Line GND
Green Line D0
White Line D1
Yellow Line WG34
Blue Line LED/BZ

Notes

  1. Before powering up, you must confirm the voltage of the power supply and the positive and negative terminals of the power supply.
  2. When using external power supply, it is recommended to share the power ground with the controller power supply.
  3. Read the head to the control box wire, it is recommended to use 8-core shielded multi-strand twisted pair network cable. Three of the cores standby, if you do not need to read the head sound and LED light feedback legal card, may not be connected to LED/BZ line, Wegen data line D0 and D1 is recommended for each other better twisted pair, line crosssectional area recommended 0.22 square millimeters or more, it is recommended that the wiring length does not exceed 100 meters, shielded wire connected to the control box motherboard GND, thickened or double stranded together a power supply to the reading head, help to enhance the performance of the reading head. . (You can also use other multi-core shielded Category 5 wire)

FCC Caution:

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

www.trudian.com/en/
HQ Add: Farbell Technology Park,Yixian Road, Nanlang,
Cuiheng New District, Zhongshan City, Guangdong Province,
China. Zip Code:528451
Phone: +86 0760 – 23689666
E-mail: [email protected]
If the problem is not solved properly,please send the mail to:
[email protected]

Documents / Resources

| Trudian TD-RM01 Reader [pdf] User Guide
2BB22-TD-RM01, 2BB22TDRM01, TD-RM01 Reader, Reader
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Trudian User Manuals

Related Manuals