Clarke CSP1530 1530W Sewage Pump Instruction Manual

June 4, 2024
Clarke

Clarke logo 1530W SEWAGE PUMP
MODEL NO: CSP1530
PART NO: 7230293
OPERATION & MAINTENANCE
INSTRUCTIONS
ORIGINAL INSTRUCTIONS
Clarke CSP1530 1530W Sewage Pump
-

INTRODUCTION

Thank you for purchasing this CLARKE submersible pump.
The CLARKE range of submersible pumps is suitable for discharging pools, ponds, fountains, pits, and any waste water drainage. They can handle foul water containing suspended material as stated in the specification. The pumps are not suitable for handling inflammable, corrosive, explosive, or dangerous liquids. The pump is water-cooled and does not contain any oil.
The ‘Pump Performance Curve’ graph shown, displays the characteristics graphically and describes the relationship between the flow rate and the head of the pump.
The pump is provided with a thermal overload cut-out so that in the event that the pump becomes overheated (due to becoming blocked etc) it will shut off automatically. When the blockage has been cleared, the thermal cutout will cool down and re-set and the pump can be re-started.
Before attempting to use this product, it is essential that you read this manual thoroughly and carefully follow all instructions given. In doing so you will ensure the safety of yourself and that of others around you, and you can also look forward to the product giving you long and satisfactory service.

SPECIFICATIONS

Voltage 230V~50Hz
Ingress Protection IP68
Outlet Diameter 2”(50mm)
Rated Output Power 1530 W
Maximum Head Height 10 m
Maximum Depth 8 m
Maximum Output 500 l/min
Maximum Operating Temperature 40 ºC
Maximum Solid body Size in Suspension 35 mm
Weight 19 kg
Cable Length 10 m
Dimensions (D x W x H) 270 x 170 x 460 mm

OVERVIEW & FEATURES

Clarke CSP1530 1530W Sewage Pump - FEATURES

  1. Water inlet screen
  2. Power cable with plug
  3. Water outlet
  4. Lifting handle

PUMP PERFORMANCE CHART

Clarke CSP1530 1530W Sewage Pump - Lifting handle

SAFETY PRECAUTIONS

WORK AREA

  1. Keep the work area clean and well-lit. Floors should always be kept clear.
    Cluttered or dark areas invite accidents.

  2. Keep children and bystanders away while operating the pump.
    Distractions can cause a loss of control.

  3. Remember, the operator or user is responsible for accidents or hazards occurring to other people or their property.

PERSONAL SAFETY

  1. ALWAYS stay alert, watch what you are doing, and use common sense when operating this pump. Do not install the pump while you are tired or under the influence of medication, drugs, or alcohol. A moment of inattention can result in personal injury.
  2. DO NOT over-reach. Keep your proper footing and balance at all times when positioning the pump.
  3. NEVER direct the water discharge towards electrical wiring or equipment.
  4. ALWAYS store the pump out of reach of children and do not allow persons unfamiliar with these instructions to operate it.
  5. NEVER direct the discharge flow toward another person.
  6. ALWAYS thoroughly familiarise yourself with this pump & its operation and follow all instructions in this manual.
  7. ALWAYS ensure that the pump is properly positioned where necessary to prevent it from moving during operation and that the immediate area surrounding the pump is kept clear.

GENERAL USE AND CARE OF THE PUMP

  1. An approved Residual Current Device (RCD) must be used when pumping from ponds or swimming pools.
  2. ALWAYS lift the pump using the handle and use a rope or chain attached if necessary to lower it into the water. Never lift or carry the pump by the power cable.
  3. NEVER use this pump if any part is damaged. Has it been inspected and repaired by your local CLARKE dealer?
  4. ALWAYS use an approved cable extension suitable for the power rating of the pump (see specifications). The conductor size should also be at least the same size as that on the pump or larger. When using a cable reel, always unwind the cable completely.
  5. ALWAYS maintain the pump with care and keep it clean.
  6. NEVER use for pumping flammable liquids or corrosive chemicals. These pumps are designed to pump water only.
  7. NEVER abuse the electrical cable. Never use the cable for pulling or unplugging the pump. Damaged or tangled cables increase the risk of electric shock.
  8. NEVER run the pump dry. Always ensure the pump is immersed in water before starting. Switch the pump OFF immediately after the task is completed
  9. NEVER pump water from a swimming pool when there is a person or animal still in the pool.
  10. NEVER install the pump on the sand, silt, or mud which is likely to shift or collapse.
  11. NEVER modify this pump in any way. Use it only for the purpose for which it is designed.

SERVICING & REPAIRS

  1. ALWAYS have the pump serviced by your local CLARKE dealer, using only identical replacement parts. This will ensure the safety of the pump is maintained. The use of nonstandard parts could be hazardous.
  2. NEVER attempt any repairs yourself unless technically qualified. If you have a problem with the pump contact your local CLARKE dealer.
  3. ALWAYS disconnect the pump from the electrical supply before placing it into, or removing it from the water, and before any cleaning or maintenance.
  4. If the power cable becomes damaged, it must be replaced rather than repaired.
  5. Your CLARKE water pump has been designed to give long and trouble-free service. If, however, having followed the instructions in this booklet carefully, you encounter problems, take the unit to your local CLARKE dealer.

ENVIRONMENTAL RECYCLING POLICY

Through the purchase of this product, the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment, recycling & recovery, and environmentally sound disposal of the WEEE.
In effect, this means that this product must not be disposed of with general household waste. It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment (WEEE) at a recognized disposal facility.
This product contains valuable raw materials. Metal products should be taken to your local civic amenity site for recycling metal products. Recycle unwanted materials instead of disposing of them as waste. All unwanted accessories and packaging should be sorted and taken to a recycling center for disposal in a manner that is compatible with the environment.

ELECTRICAL CONNECTIONS

WARNING: READ THESE ELECTRICAL SAFETY INSTRUCTIONS THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAIN SUPPLY.

Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply through an approved 13 amp BS 1363 plug or a suitably fused isolator switch. If the plug has to be changed because it is not suitable for your socket, or because of damage, it must be removed and a replacement fitted, following the wiring instructions are shown below. The old plug must be discarded safely, as insertion into a power socket could cause an electrical hazard.
If the colors of the wires in the power cable do not agree with the markings on the plug proceed as follows

  • The BLUE wire must be connected to the terminal marked N or colored black.
  • The BROWN wire must be connected to the terminal marked L or colored red.
  • The YELLOW AND GREEN wires must be connected to the terminal marked E or **** colored green.

Clarke CSP1530 1530W Sewage Pump - approved

AN APPROVED RESIDUAL CURRENT DEVICE (RCD) THAT HAS A TRIPPING CURRENT OF LESS THAN 30MA MUST BE USED.
If you are not sure, consult a qualified electrician. DO NOT try to do any repairs.

POSITIONING AND CONNECTION

Remove all packaging and make sure that the unit contains no visible damage. Dispose of all packaging appropriately.

CONNECTING THE PUMP

  1. Connect the outlet adaptor to the largest diameter hose available, as any restriction will reduce capacity and put unnecessary strain on the motor if a long run of discharge hose is being used.
    • The adaptor fitting allows for the connection of 51 mm (2”) hoses which should be secured with a hose clamp.
    • Suitable hoses are available from your local CLARKE dealer.

POSITIONING THE PUMP

  1. It may be safer to raise and lower the pump into deep water using a rope attached to the lifting handle.
  2. Place the pump in a vertical position resting on a firm, flat surface in the area that you want to drain. If there is sediment in the operating area, the pump should be placed vertically on house bricks, or similar but ensure they are not likely to collapse. Never position the pump on sand, silt, mud, or ground which is likely to collapse.
  3. Keep the pump clear of sediment by standing it on a platform or brick or suspending it from a rope attached to the handle if the pump is to be used where there may be silt or mud etc (e.g. garden ponds).
  4. Route the hose as straight as possible. Excessive bending of the hose could obstruct the flow of water, reduce the pumping volume or clog the pump with mud, thus disabling the function of the pump. If the hose is kinked at its base it will create air pockets in the pump, causing it to operate in a partially dry state. Take care to straighten any kinks or bends in the hose.
  5. Do not operate the pump if the water is too shallow. This will be below the level of the outlet elbow with the impeller fully immersed.
  6. Allowance must also be made for the overall width of the pump including the outlet elbow on one side.
    • When the pump is being used in a permanent or semi-permanent installation, a non-return valve should be fitted in the delivery hose. Suitable hoses and valves are available from your CLARKE dealer.
    • Take all necessary precautions as described on pages 4-5.
    • The pump inlet must be fully submerged before being switched on.

USING THE PUMP

WARNING: CHECK THE PUMP FOR DAMAGE BEFORE USE, DO NOT USE THE PUMP IF IT IS DAMAGED IN ANY WAY.

  1.  Plug in the pump and switch on the power supply.
    • Suitable hoses are available from your local CLARKE dealer.

  2.  Run the pump continuously or remove it from the water and store it in a frost-free location if the water is likely to freeze.

  3. NEVER run the pump dry. Ensure the pump is switched off when the water has stopped flowing.
    • The pump should be able to clear water down to a residual depth of the inlet port, In this situation, air and residual water may be seen escaping from the discharge hose.

  4. Disconnect from the power supply when the water has been pumped out.
    Avoid running the pump continuously if the discharge hose has become obstructed and water is not flowing.

  5. Disconnect the pump from the mains supply before placing it into or removing it from the water.

  6.  NEVER carry the pump by the power cable. Always use the handle or a rope tied securely to the handle.

  7. NEVER insert your fingers into the pump whilst it is connected to the mains.

  8. DO NOT use the pump if the water is liable to freeze, as this can cause damage to the pump. Remove the pump from the water and store it in a frost-free location.

OVERLOAD PROTECTION
These pumps are fitted with automatic thermal overload protection.
If the pump overheats due to an obstruction in the pump or pumping warm water, for example, it will shut off automatically.
Switch the pump OFF at the mains supply. Check for blockages and allow the motor to cool (at least 5 minutes) by which time the cut-out will have reset.
Once the pump has cooled the pump will automatically restart.

CLEANING, MAINTENANCE & STORAGE

**WARNING:** MAKE SURE THAT THE PUMP IS DISCONNECTED FROM THE POWER SUPPLY BEFORE CLEANING OR PERFORMING MAINTENANCE

The pump should require no maintenance other than regular inspection and cleaning.

  1. Inspect the pump prior to use and DO NOT use the pump if there is any damage to the mains power cable.
  2. Check the pump regularly to ensure the inlet is clear of leaves or other debris. It can be cleaned out either by back-flushing or cleaning out by hand.
  3. If the pump has been used for pumping swimming pool water or salty water is likely to leave chemical residues, it should be flushed through with clean water before storage.
  4. When the pump is not being used for extended periods, clean and dry it thoroughly and store it indoors. if the pump is left in water, it should be run at least once a week to prevent it from seizing up.
  5. If the pump shows signs of wear or damage, contact your CLARKE dealer for advice. DO NOT attempt to repair the pump yourself, as you may damage the waterproof seals and invalidate your guarantee. Repairs should be carried out by your local CLARKE dealer, or contact the CLARKE Service Department on 020 8988 7400.

TROUBLESHOOTING

PROBLEM CAUSE AND REMEDY
THE PUMP WILL NOT START 1. Make sure that the power is switched on.

2. Check the fuse (consult an electrician if in doubt).
3. If the extension lead is fitted, check connections (consult an electrician if in doubt).
4. Internal thermal cut-out has not re-set. Leave for 5-10 minutes and try again.
5. The impeller may be jammed. Disconnect from the mains supply and remove any objects that may be obstructing
the impeller.
6. If the pump still fails to start, consult your CLARKE dealer.
THE PUMP WILL START BUT NOT PUMP| 1. Check that the inlet is not blocked.
2. Check that the discharge tube is not clogged or obstructed.
3. The head may be too great, i.e. you are trying to lift the water too great a distance for the pump to cope with.
4. Air bubbles in the pump, are produced during immersion.
Immerse the pump again, at an angle, and shake it whilst lowering to remove any air trapped in the system.
5. Impeller may be damaged – Consult your CLARKE dealer.
PUMP STOPS RUNNING| 1. Thermal overload has operated. Leave for 5-10 minutes and try again.
2. A foreign object has jammed the impeller.

If this does not solve your problem, please contact the CLARKE service department.

COMPONENT PARTS

Clarke CSP1530 1530W Sewage Pump - COMPONENT PARTS

1 Top cover 14 Shaft sleeve
2 Bearing cover 15 Key
3 Motor casing 16 Oil seal
4 Rotor 17 O-ring
5 Stator 18 O-ring
6 Bearing bracket 19 O-ring
7 Seal cover 20 O-ring
8 Impeller 21 Gasket
9 Pump casing 22 Handle
10 Capacitor 23 Cable
11 Bearing 24 Outlet connector
12 Bearing 25 Gasket
13 Mechanical seal 26

ACCESSORIES

Hoses Hose Clips

• Available in 100 meter coils or perimeter.
• Available in ¾” – 3” Diameter.| • Various sizes available
• Zinc plated for corrosion resistance.

GUARANTEE

This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt which will be required as proof of purchase.
This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended.
Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission.
This guarantee does not affect your statutory rights.

DECLARATION OF CONFORMITY-UK

Clarke CSP1530 1530W Sewage Pump - sartificate

DECLARATION OF CONFORMITY-EU

Clarke CSP1530 1530W Sewage Pump - sartificate1

Clarke CSP1530 1530W Sewage Pump - 1

PARTS & SERVICE: 0208 988 7400
Parts Enquiries Parts@clarkeinternational.com
Servicing & Technical Enquiries Service@clarkeinternational.com
SALES: UK 01992 565333 or Export 00 44 (0)1992 565335
Clarke logo INTERNATIONAL Hemnall Street, Epping, Essex CM16 4LG
www.clarkeinternational.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals