MEAN WELL LRS-150F Series Single Output Switching Power Supply Owner’s Manual

June 12, 2024
MEAN WELL

MEAN WELL LRS-150F Series Single Output Switching Power Supply

MEAN-WELL-LRS-150F-Series-Single-Output-Switching-Power -Supply-FIG-
\(2\)

Product Information

The LRS-150F series is a 150W Single Output Switching Power Supply. It is designed to provide reliable and efficient power for various applications. The power supply is compliant with safety standards such as AS/NZS62368-1, GB4943.1, UL62368-1, Bauar t gepruft Sicherheit, and TP TC004 IEC62368-1. It has been tested and certified by TUV.

Specifications

Model| Output Voltage| Rated Current| Current Range| Rated Power| Ripple & Noise (max.)| Setup, Rise Time| Hold Up Time (Typ.)| Voltage Range| Frequency Range| Efficiency (Typ.)| Input AC Current (Typ.)| Inrush Current (Typ.)| Leakage Current
---|---|---|---|---|---|---|---|---|---|---|---|---|---
LRS-150F-5| 5V| 22A| 0 ~ 22A| 110W| 100mVp-p| 500ms, 30ms/230VAC
500ms, 30ms/115VAC at full load| 16ms/230VAC
12ms/115VAC at full load| 85 ~ 264VAC
120 ~ 370VDC| 47 ~ 63Hz| 85%| 3A/115VAC
1.7A/230VAC| COLD STAR 60A/230VAC|
LRS-150F-12| 12V| 12.5A| 0 ~ 12.5A| 150W| 150mVp-p| 500ms, 30ms/230VAC
500ms, 30ms/115VAC at full load| 16ms/230VAC
12ms/115VAC at full load| 85 ~ 264VAC
120 ~ 370VDC| 47 ~ 63Hz| 87.5%| 3A/115VAC
1.7A/230VAC| COLD STAR 60A/230VAC|
LRS-150F-15| 15V| 10A| 0 ~ 10A| 150W| 150mVp-p| 500ms, 30ms/230VAC
500ms, 30ms/115VAC at full load| 16ms/230VAC
12ms/115VAC at full load| 85 ~ 264VAC
120 ~ 370VDC| 47 ~ 63Hz| 89%| 3A/115VAC
1.7A/230VAC| COLD STAR 60A/230VAC|
LRS-150F-24| 24V| 6.5A| 0 ~ 6.5A| 156W| 200mVp-p| 500ms, 30ms/230VAC
500ms, 30ms/115VAC at full load| 16ms/230VAC
12ms/115VAC at full load| 85 ~ 264VAC
120 ~ 370VDC| 47 ~ 63Hz| —| —| —|
LRS-150F-36| 36V| —| —| —| —| —| —| —| —| —| —| —| —
LRS-150F-48| 48V| —| —| —| —| —| —| —| —| —| —| —| —

Product Usage Instructions

To use the LRS-150F series Single Output Switching Power Supply, follow these instructions:

  1. Choose the appropriate model based on the required output voltage and current.
  2. Ensure that the input voltage falls within the specified voltage range (85 ~ 264VAC or 120 ~ 370VDC) and frequency range (47  ~ 63Hz).
  3. Connect the AC power source to the power supply using suitable cables or connectors.
  4. Connect the load to the power supply’s output terminals, ensuring correct polarity.
  5. If required, adjust the output voltage using the provided adjustment mechanism.
  6. Switch on the AC power source.

Note : Refer to the user manual for detailed safety instructions and precautions before using the power supply.

Features

  • Universal AC input / Full range
  • Withstand 300VAC surge input for 5 second
  • No load power consumption<0.5W
  • Miniature size and 1U low profile
  • High operating temperature up to 70°C
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection
  • Compliance to IEC/BS EN/EN 60335-1 (PD3) and IEC/BS EN/EN61558-1, 2-16 for household appliances
  • Operating altitude up to 5000 meters
  • Withstand 5G vibration test
  • High efficiency, long life and high reliability
  • LED indicator for power on
  • Over voltage category Ill
  • 100% full load burn-in test
  • 3 vears warranty

Applications

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments, equipments or apparatus
  • Household appliances

GTIN CODE MW Search : https://www.meanwell.com/serviceGTIN.asox

Description

  • LRS-150F series is a 150W single-output enclosed type power supply with 30mm of low profile design.
  • Adopting the full range 85~264VAC input, the entire series provides an output voltage line of 5V, 12V, 15V, 24V, 36V and 48V.
  • In addition to the high efficiency up to 90%, the design of metallic mesh case enhances the heat dissipation of LRS-150F that the whole series operates from -30°C through 70°C under air convection without a fan.
  • Delivering an extremely low no load power consumption (less than 0.5W), it allows the end system to easily meet the worldwide energy requirement. LRS-150F has the complete protection functions and 5G anti- vibration capability; it is complied with the international safety regulations such as TUV BS EN/EN62368-1, BS EN/EN60335-1,BS EN/EN61558-1/-2-16, UL62368-1 and GB4943. LRS-150F series serves as a high price-to-performance power supply solution for various industrial applications.

Model EncodingMEAN-WELL-LRS-150F-Series-Single-Output-Switching-Power
-Supply-FIG- 8

SPECIFICATION

MODEL|  | LRS-150F-5| LRS-150F-12| LRS-150F-15| LRS- 150F-24| LRS-150F-36| LRS-150F-48
---|---|---|---|---|---|---|---






OUTPUT

| DC VOLTAGE| 5V| 12V| 15V| 24V| 36V| 48V
RATED CURRENT| 22A| 12.5A| 10A| 6.5A| 4.3A| 3.3A
CURRENT RANGE| 0 ~ 22A| 0 ~ 12.5A| 0 ~ 10A| 0 ~ 6.5A| 0 ~ 4.3A| 0 ~ 3.3A
RATED POWER| 110W| 150W| 150W| 156W| 154.8W| 158.4W
RIPPLE & NOISE (max.) Note.2| 100mVp-p| 150mVp-p| 150mVp-p| 200mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 4.5 ~ 5.5V| 10.2 ~ 13.8V| 13.5 ~ 18V| 21.6 ~ 28.8V| 32.4 ~ 39.6V| 43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION Note.4| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION Note.5| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 500ms, 30ms/230VAC        500ms,30ms/115VAC at full load
HOLD UP TIME (Typ.)| 16ms/230VAC      12ms/115VAC at full load



INPUT

| VOLTAGE RANGE| 85 ~ 264VAC         120 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 85%| 87.5%| 89%| 89%| 89%| 90%
AC CURRENT (Typ.)| 3A/115VAC         1.7A/230VAC
INRUSH CURRENT (Typ.)| COLD STAR 60A/230VAC
LEAKAGE CURRENT| <0.75mA / 240VAC



PROTECTION

| OVER LOAD| 110 ~ 140% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 5.75 ~ 6.75V| 13.8 ~ 16.2V| 18.75 ~ 21.75V| 28.8 ~ 33.6V| 41.4 ~ 48.6V| 55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, re-power on to recover



ENVIRONMENT

| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY| Ⅲ; Compliance to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters



SAFETY & EMC

(Note 7)

| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,CCC GB4943.1, BSMI CNS15598-1,EAC TP TC004, AS/NZS 62368.1(by CB) approved
WITHSTAND VOLTAGE| I/P-O/P:4KVAC  I/P-FG:2KVAC  O/P-FG:1.25KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2 Class A(≤80% Load ), GB/T 9254, BSMI CNS15936, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020


OTHERS

| MTBF| 2761.8K hrs min.       Telcordia SR-332 (Bellcore) ; 592.4Khrs min.        MIL-HDBK-217F (25℃)
DIMENSION| 1599730mm (LWH)
PACKING| 0.48Kg ; 30pcs/15.4Kg/0.75CUFT

NOTE

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0. 1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Line regulation is measured from low line to high line at rated load.
  5. Load regulation is measured from 0% to 100% rated load.
  6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
  7. The power supply is considered a component which will be installed into a final equipment. All the MC tests are been executed by mounting the unit on a 360mm *360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it till meets EMC directives. For guidance on how to perform these MC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
  8. The ambient temperature derating of 5°C/1000m is needed for operating altitude greater than 2000m (6500ft). Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

MEAN-WELL-LRS-150F-Series-Single-Output-Switching-Power
-Supply-FIG- \(4\)

Derating Curve

Static Characteristics

Mechanical SpecificationMEAN-WELL-LRS-150F-Series-Single-Output-
Switching-Power -Supply-FIG- \(7\)

Terminal Pin No. Assignment

Pin No. Assignment Pin No. Assignment
1 AC/L 4,5 DC OUTPUT -V
2 AC/N 6,7 DC OUTPUT +V
3 FG    