ROBB 16A ZigBee In Wall Switch
Important: Read All Instructions Prior to Installation
Function introduction
Product Data
Input Voltage | Output Voltage | Output Current | Size(LxWxH) |
---|---|---|---|
100-240VAC | 100-240VAC | 16A max | 45.5x45x20.3mm |
Over Current Protection
- When load current is over 16.1A for over 10 seconds, the relay will be forced to off and protected.
- When load power is over 3700W for over 5 seconds, the relay will be forced to off and protected.
- ZigBee in-wall switch based on latest ZigBee 3.0 protocol
- 100-240VAC wide input and output voltage
- Supports resistive loads and capacitive loads
- 1 channel output, max. load 16A
- Input and output with screw terminals, safe and reliable
- Enables to control ON/OFF of connected load
- ZigBee end device that supports Touchlink commissioning
- Can directly pair to a compatible ZigBee remote via Touchlink without coordinator
- Supports self-forming zigbee network without coordinator and add other devices to the network
- Supports find and bind mode to bind a ZigBee remote
- Supports zigbee green power and can bind max. 20 zigbee green power switches
- Compatible with universal ZigBee gateway products
- Can be controlled by toggle on/off switches
- Active power and energy metering functionality
- Mini size, easy to be installed into a standard size wall box
- Radio frequency : 2.4GHz
- Waterproof grade: IP20
Safety & Warnings
- DO NOT install with power applied to device.
- DO NOT expose the device to moisture.
ZigBee Clusters the device supports are as follows:
Input Clusters
- 0x0000: Basic
- 0x0003: Identify
- 0x0004: Groups
- 0x0005: Scenes
- 0x0006: On/off
- 0x0702: Simple Metering
- 0x0b04: Electrical Measurement
- 0x0b05: Diagnostics
Output Clusters
• 0x0019: OTA
Operation
- Do wiring according to connection diagram correctly.
- This ZigBee device is a wireless receiver that communicates with a variety of ZigBee compatible systems. This receiver receives and is controlled by wireless radio signals from the compatible ZigBee system.
- Zigbee Network Pairing through Coordinator or Hub (Added to a Zigbee Network)
Step 1: Remove the device from previous zigbee network if it has already been
added to, otherwise pairing will fail. Please refer to the part “Factory Reset
Manually”.
Step 2: From your ZigBee Controller or hub interface, choose to add lighting
device and enter Pairing mode as instructed by the controller.
TouchLink to a Zigbee Remote
Note:
- Directly TouchLink (both not added to a ZigBee network), each device can link with 1 remote.
- TouchLink after both added to a ZigBee network, each device can link with max. 30 remotes.
- To control by both gateway & remote, add remote and device to network first then TouchLink.
- After TouchLink, the device can be controlled by the linked remotes.
Removed from a Zigbee Network through Coordinator or Hub Interface
Factory Reset Manually
Note:
- If the device is already at factory default setting, there is no indication when factory reset again .
- All configuration parameters will be reset after the device is reset or removed from the network.
Factory Reset through a Zigbee Remote (Touch Reset)
Note: Make sure the device already added to a network, the remote added to the same one or not added to any network.
Find and Bind Mode
Note: Make sure the device and remote already added to the same zigbee
network.
Learning to a Zigbee Green Power Switch
Note: Each device can learn to max. 20 zigbee green power switches.
Delete Learning to a Zigbee Green Power Switch
Setup a Zigbee Network & Add Other Devices to the Network (No Coordinator Required)
Step 2: Set another device or remote or touch panel into network pairing mode
and pair to the network, refer to their manuals.
Step 3: Pair more devices and remotes to the network as you would like, refer
to their manuals.
Step 4: Bind the added devices and remotes through Touchlink so that the
devices can be controlled by the remotes, refer to their manuals.
Note:
- Each added device can link and be controlled by max. 30 added remotes.
- Each added remote can link and control max. 30 added devices.
OTA
The device supports firmware updating through OTA, and will acquire new
firmware from zigbee controller or hub every 10 minutes automatically.
Wiring Diagram
Notes for the diagrams:
L – terminal for live lead
N – terminal for neutral lead
L1 – output terminals of the device (controlling connected light source)
S – terminal for external switch
NC – No Connection
With Light Load
Connect With Socket
Product Dimension
Documents / Resources
| ROBB
16A ZigBee In Wall
Switch
[pdf] Instruction Manual
ROB_200-035-0_DEMO_download_1.pdf, SR-ZG9101SAC-HP-SWITCH-B-A instruction.cdr,
09.ZG09SAPB.04736, 16A ZigBee In Wall Switch, 16A Switch, ZigBee In Wall
Switch, In Wall Switch, ZigBee Switch, Switch
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>