ROBB ROB-100-006-0 Z-Wave RGBW Remote Control Instruction Manual
- June 12, 2024
- ROBB
Table of Contents
ROBB ROB-100-006-0 Z-Wave RGBW Remote Control
Product Information
- Product Name: Z-Wave RGBW Remote Control
- Model Number: ROB_100-006-0
- Battery: CR2450
- Z-Wave Frequency: 868.42MHz
- Power Supply: 3VDC (1xCR2450 battery)
- Operating Temperature: Not specified
- Relative Humidity: Not specified
- Dimensions: 71.20mm x 55.57mm x 11mm
- Waterproof Grade: IP20
- Encryption Modes Supported: S0, S2 Authenticated, S2 Unauthenticated
- Product Usage Instructions
Function introduction
Product Data
Z-Wave Frequency | 868.42MHz |
---|---|
Power Supply | 3VDC(1xCR2450 battery) |
Operating temperature | 0 to 40°C |
Relative humidity | 8% to 80% |
Dimensions | 71.2×71.2×13.6mm |
Waterproof Grade | IP20 |
Safety & Warnings
- This device contains a button lithium battery that shall be stored and disposed of properly.
- DO NOT expose the device to moisture.
Quick Start
How to install:
- Step 1: turn on your remote control.
- Step 2: activate inclusion mode on your Z-Wave controller.
- Step 3: activate the inclusion mode of your remote control by pressing and holding down both buttons and of Group 2 together over 3 seconds.
Product Description
The remote control is a Z-Wave device that can both control other Z-Wave
devices and activate scenes in Gateways. Although it is controlling other
devices, the device cannot act as Z-Wave network controller (primary or
secondary) and will always need a Z-Wave network controller to be included
into a Z-Wave network. It also supports the Over The Air (OTA) feature for the
product’s firmware upgrade.
The remote control has the following functions:
- Control of groups of other Z-Wave devices using ‘ON’, ‘OFF’, Dim and RGB color control commands.
- Activation of scenes in Gateway mode.
The encryption modes that the remote control supports are S0, S2 Authenticated, S2 Unauthenticated. When the remote control is being included into a Z-Wave network, you can use your primary controller/gateway to enable one encryption mode or disable encryption. (The primary controller/gateway shall support encryption mode configuration).
Installation Guide
Please read carefully the enclosed user manual before installation of remote
control, in order to ensure an error-free functioning.
The remote control unit is supplied as a complete set for flush mounting in
the standard circular European wall boxes with 60mm diameter.
Exclusion (Removing from a Z-Wave network)
There are two exclusion methods:
Method 1: Exclusion from the primary controller/gateway as follows:
- Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion).
- Press and hold down both buttons and of Group 2 over 3 seconds, LED indicator turns on, the remote control will be set to exclusion mode, and waiting to be excluded, after 7s LED indicator blinks 4 times quickly to indicate successful exclusion.
Method 2: Factory reset the remote control will force the remote control
to be excluded from a network. (please refer to the part “Factory Reset” of
this manual)
Note: Factory reset is not recommended for exclusion, please use this
procedure only if the primary controller/gateway is missing or otherwise
inoperable.
How to check whether the remote control already included to a network
Short press any button, if LED indicator blinks 3 times, the remote control
does not belong to any network, if LED indicator turns on, it means the remote
control has already been included to a network.
If the remote control already belongs to a network, follow the exclusion
process before including it in your network. Otherwise, inclusion of this
device will fail.
Inclusion (Adding to a Z-Wave network)
- Make sure the remote control does not belong to any Z-Wave network. Short press any button. If the LED indicator does not turn on, the remote control does not belong to any network. Proceed to step 2. If the LED indicator turns on, it means the remote control has already been included in a network. In this case, set the remote control to exclusion mode (refer to the part Exclusion of this manual) and then proceed to step 2.
- Set the primary controller/gateway into inclusion mode. Refer to your primary controller’s manual for instructions on how to turn it into inclusion mode.
Factory Reset
Press and hold down both buttons of Group 2 together for over 10 seconds, LED
indicator turns on and then blinks 4 times quickly to indicate successful
factory reset.
Association
Z-Wave devices control other Z-Wave devices. The relationship between one
device controlling another device is called association. In order to control a
different device, the controlling device needs to maintain a list of devices
that will receive controlling commands. These lists are called association
groups and they are always related to certain events (e.g. button pressed). In
case the event happens all devices stored in the respective association group
will receive a common wireless command.
Association Groups:
Each group supports maximum 5 nodes for association, the same device can be
associated with multiple groups on the remote control simultaneously, to
ensure better control experience, the remote control shall remove the
associated devices that are not under working status from association groups
in time.
Association Groups | Group Name | Max Nodes | Description |
---|
Group 1
|
Lifeline
|
5
| 1. Send Command Class “Device Reset Locally Notification V1” to associated devices of this group to report factory reset information when factory reset the remote control.
2. When the remote control battery power value changes, send Command Class “Battery Report V1” to associated devices of this group to report power value information.
3. Short press or press and hold down any button to send scene activation command to the associated devices of this group using Command Class “Central Scene Notification V3”
Group 2
|
Launch 1
|
5
| • Short press button to send ON/OFF command to associated devices of this group using Command Class “Basic Set V2”.
• Press and hold down the button to send light intensity increase/decrease command to associated devices of this group using Command Class “Multilevel V4”.
• Short press W/ button of Group 2, turn on/off white/RGB channel of associated devices of this group using the Command Class “Color Switch Set”.
• Press and hold down W/ button of Group 2, adjust the intensity of the white/RGB channel of associated devices of this group using the Command Class “Color Switch Start Level Change”.
Set and unset associations:
(Note: All association information will be cleared automatically once the
remote control is excluded from a network.)
There are two methods to set associations:
-
Set association by operating the primary controller/gateway to send association command to the remote control:
When set the association from the primary controller/gateway, the remote control shall be activated first, if it is not activated, you should activate it manually.
The primary controller/gateway sends association commands to the remote control using “Command Class ASSOCIATION” or “Command Class Multi Channel Association” -
Set association by operating the remote control and devices to be controlled:
To control a Z-Wave device from the remote control the node ID of this device needs to be assigned to one of the two association groups.
This is a three-step process:
- Press and hold down both buttons of Group 2 over 3 seconds, LED indicator turns on.
- Short press button within 7s to associate the device to this group, short press to remove the association of the device from this group.
- Operate the device to be controlled to send Node Information Frame (please refer to the device manual) within 10 seconds, or set the device to exclusion mode within 10 seconds, since it will send Node Information Frame in exclusion mode, LED indications are as follows:
LED blinks twice to indicate that the remote control failed to add the associated device (the association group has already added the maximum quantity of associated devices that it supports ).
LED blinks 5 times to indicate that the remote control added the associated
device successfully. LED blinks 8 times to indicate that the remote control
removed the associated device successfully.
To remove all associated devices in an association group on the remote control
directly:
- Press and hold down both buttons and of Group 2 over 3 seconds, LED indicator turns on.
- Click button on the remote control 5 times continuously within 7 seconds to remove all associated devices of this group, LED indicator blinks 8 times to indicate that the associated devices are removed successfully.
Operating the device
- Short press the button of Group 2, send ON/OFF command to all associated devices of Association Group 2.
- Press and hold down button of Group 2, send light intensity increase/decrease command to all associated devices of Association Group 2.
- Short press W button of Group 2, send Color Switch Set commands to all associated devices of Association Group 2.
- Press and hold down W button of Group 2, send Color Switch Start Level Change commands to all associated devices of Association Group 2.
- Short press button of Group 2, send Color Switch Set commands to all associated devices of Association Group 2.
- Press and hold down button of Group 2, send Color Switch Start Level Change commands to all associated devices of Association Group 2.
- Short press/press and hold any button to send scene activation command to association group 1 using Command Class “Central Scene Notification V3”.
How to communicate with the device
The remote control is under sleepy mode for most of the time to save battery
power. It can not receive wireless command under sleepy mode. Before the
gateway interacts data with the remote, the remote control shall be activated
manually first. Short press any button to activate the remote control for 3s,
and press and hold down buttons of Group 2 together over 1 second to activate
the remote control for 7s.
Node Information Frame
The Node Information Frame is the business card of a Z-Wave device. It
contains information about the device type and the technical capabilities. The
inclusion and exclusion of the device is confirmed by sending out a Node
Information Frame. Beside this it may be needed for certain network operations
to send out a Node Information Frame.
How to send out Node Information Frame:
Set the wall controller into inclusion/exclusion mode: Press and hold down
both and over 3 seconds, LED indicator turns on to indicate the wall
controller has already sent out Node Information Frame, the user can repeat
the operation to set the wall controller to quit “inclusion/exclusion mode”.
Technical Data
Battery Type | 1*CR2450 |
---|---|
Frequency | 868.42 MHz |
Wireless Range | up to 100 m outside, on average up to 20 m inside buildings |
SDK | 6.71.01 |
Explorer Frame Support | Yes |
Device Type | Wall Controller |
Generic Device Class | Switch Remote |
Specific Device Class | Switch Remote Multilevel |
Routing | No |
FLiRS | No |
Z-Wave Plus Info
Parameter | Value |
---|---|
Z-Wave Plus Version | 1 |
Role Type | Slave Portable |
Node Type | ZWAVEPLUS |
Installer Icon Type | 0x0b00 (ICON_TYPE_GENERIC_REMOTE_CONTROL_SIMPLE) |
User Icon Type | 0x0b00 (ICON_TYPE_GENERIC_REMOTE_CONTROL_SIMPLE) |
Manufacturer Specific
Parameter Value (hex)
Manufacturer ID 0x0330
Product Type ID 0x0003
Product ID 0xa30c
SUPPORTED COMMAND CLASS
- COMMAND_CLASS_ZWAVEPLUS_INFO_V2
- COMMAND_CLASS_ASSOCIATION_V2
- COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
- COMMAND_CLASS_CENTRAL_SCENE_V3
- COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
- COMMAND_CLASS_TRANSPORT_SERVICE_V2
- COMMAND_CLASS_VERSION_V2
- COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
- COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
- COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
- COMMAND_CLASS_POWERLEVEL_V1
- COMMAND_CLASS_BATTERY_V1
- COMMAND_CLASS_SECURITY_V1
- COMMAND_CLASS_SECURITY_2_V1
- COMMAND_CLASS_WAKE_UP_V2
- COMMAND_CLASS_SUPERVISION_V1
Controlled Command Classes
- COMMAND_CLASS_CENTRAL_SCENE_V3
- COMMAND_CLASS_BASIC_V2
- COMMAND_CLASS_SWITCH_MULTILEVEL_V4
- COMMAND_CLASS_SWITCH_COLOR_V3
- Multi-Channel V3
- Security_V1
- Security_2_V1
Installation
- Remove battery insulator
- Install the controller to wall(2 methods)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>