ROBB 100-025-0 Z-Wave Dim Remote Control User Manual
- October 30, 2023
- ROBB
Table of Contents
ROBB 100-025-0 Z-Wave Dim Remote Control User Manual
Important: Read All Instructions Prior to Installation
Function introduction
Product Data
Z-Wave Frequency | 868.42MHz |
---|---|
Power Supply | 3VDC(1xCR2450 battery) |
Operating temperature | 0 to 40°C |
Relative humidity | 8% to 80% |
Dimensions | 71.2×71.2×13.6mm |
Waterproof Grade | IP20 |
Safety & Warnings
- This device contains a button lithium battery that shall be stored and disposed properly.
- DO NOT expose the device to moisture.
Quick Start
How to install:
- Step 1: turn on your remote control.
- Step 2: activate inclusion mode on your Z-Wave controller.
- Step 3: activate inclusion mode of your remote control by pressing and holding down both buttons and of Group 2 together over 3 seconds.
Product Description
The remote control is a Z-Wave device that can both control other Z-Wave devices and activate scenes in Gateways. Although it is controlling other devices, the device cannot act as Z-Wave network controller (primary or secondary) and will always need a Z-Wave network controller to be included into a Z-Wave network. It also supports the Over The Air (OTA) feature for the product’s firmware upgrade.
The remote control has following functions:
- Control of groups of other Z-Wave devices using ‘ON’, ‘OFF’ and Dim commands.
- Activation of scenes in Gateway mode.
The encryption modes that the remote control supports are S0, S2 Authenticated, S2 Unauthenticated. When the remote control is being included into a Z-Wave network, you can use your primary controller/gateway to enable one encryption mode or disable encryption. (The primary controller/gateway shall support encryption mode configuration).
Installation Guide
Please read carefully the enclosed user manual before installation of remote
control, in order to ensure an error free functioning. The remote control unit
supplied as complete set for flush mounting in the standard circular European
wall boxes with 60mm diameter.
Inclusion (Adding to a Z-Wave network)
Step 1. Make sure the remote control does not belong to any Z-Wave
network, short press any button, if LED indicator does not turn on, the remote
control does not belong to any network, then continue step 2,if LED indicator
turns on, it means the remote control has already been included to a network,
please first set the remote control to exclusion mode (refer to the part
“Exclusion” of this manual),then continue step 2.
Step 2. Set primary controller/gateway into inclusion mode (Please refer
to your primary controllers manual on how to turn your controller into
inclusion).
Step 3. Press and hold down both buttons and of Group 2 over 3 seconds,
LED indicator turns on, the remote control will be set to inclusion mode, and
waiting to be included, after 10s LED indicator blinks 6 times quickly to
indicate successful inclusion. The remote control is a sleepy device, after
inclusion it will not enter into sleepy mode immediately, and will continue
activation status for 30s and wait data interaction from the gateway, the LED
indicator will stay solid on, please be patient to wait LED indicator to turn
off.
Exclusion (Removing from a Z-Wave network)
There are two exclusion methods:
Method 1: Exclusion from the primary controller/gateway as follows:
- Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion).
- Press and hold down both buttons and of Group 2 over 3 seconds, LED indicator turns on, the remote control will be set to exclusion mode, and waiting to be excluded, after 7s LED indicator blinks 4 times quickly to indicate successful exclusion.
Method 2: Factory reset the remote control will force the remote control
to be excluded from a network. (please refer to the part “Factory Reset” of
this manual)
Note: Factory reset is not recommended for exclusion, please use this
procedure only if the primary controller/gateway is missing or otherwise
inoperable.
How to check whether the remote control already included to a network
Short press any button, if LED indicator blinks 3 times, the remote control
does not belong to any network, if LED indicator turns on, it means the remote
control has already been included to a network. If the remote control already
belongs to a network, follow the exclusion process before including it in your
network. Otherwise inclusion of this device will fail.
Factory Reset
Press and hold down both buttons and of Group 2 for over 10 seconds, LED
indicator turns on and then blinks 4 times quickly to indicate successful
factory reset.
Association
Z-Wave devices control other Z-Wave devices. The relationship between one
device controlling another device is called association. In order to control a
different device, the controlling device needs to maintain a list of devices
that will receive controlling commands. These lists are called association
groups and they are always related to certain events (e.g. button pressed). In
case the event happens all devices stored in the respective association group
will receive a common wireless command.
Association Groups:
Each group supports maximum 5 nodes for association, the same device can be
associated with multiple groups on the remote control simultaneously, to
ensure better control experience, the remote control shall remove the
associated devices that are not under working status from association groups
in time.
Association Groups | Group Name | Max Nodes | Description |
---|
Group 1
|
Lifeline
|
5
|
1. Send Command Class “Device Reset Locally Notification V1” to associated devices of this group to report factory reset information when factory reset the remote control.2. When remote control battery power value changes, send Command Class “Battery Report V1” to associated devices of this group to report power value information.3. Short press or press and hold down any button to send scene activation command to the associated devices of this group using Command Class “Central Scene Notification V3”
Group 2
|
Launch 1
|
5
|
Short press / button of Group 2 to send ON/OFF command to associated devices of this group using Command Class “Basic Set V2”.Press and hold down / button of Group 2 to send light intensity increase/decrease command to associated devices of this group using Command Class “Multilevel V4”.
Group 3
|
Launch 2
|
5
|
Short press / button of Group 3 to send ON/OFF command to associated devices of this group using Command Class “Basic Set V2”.Press and hold down / button of Group 3 to send light intensity increase/decrease command to associated devices of this group using Command Class “Multilevel V4”.
Group 4
|
Launch 3
|
5
|
Short press / button of Group 4 to send ON/OFF command to associated devices of this group using Command Class “Basic Set V2”.Press and hold down / button of Group 4 to send light intensity increase/decrease command to associated devices of this group using Command Class “Multilevel V4”.
Group 5
|
Launch 4
|
5
|
Short press / button of Group 5 to send ON/OFF command to associated devices of this group using Command Class “Basic Set V2”.Press and hold down / button of Group 5 to send light intensity increase/decrease command to associated devices of this group using Command Class “Multilevel V4”.
Set and unset associations:
(Note: All association information will be cleared automatically once the remote control is excluded from a network.) There are two methods to set associations:
- Set association by operating primary controller/gateway to send association command to the remote control: When set association from primary controller/gateway, the remote control shall be activated first, if it is not activated, you should activate it manually. The primary controller/gateway sends association command to the remote control using “Command Class ASSOCIATION” or “Command Class Multi Channel Association”
- Set association by operating the remote control and devices to be controlled:
To control a Z-Wave device from the remote control the node ID of this device needs to be assigned to one of the two association groups. This is a three- step process:
- Press and hold down both buttons and of Group 2 over 3 seconds, LED indicator turns on.
- Short press ON button of any group within 7s to associate the device to this group, short press OFF button of any group within 7s to remove association of the device from this group.
- Operate the device to be controlled to send Node Information Frame (please refer to the device manual) within 10 seconds, or set the device to exclusion mode within 10 seconds, since it will send Node Information Frame in exclusion mode, LED indications are as follows:
LED blinks twice to indicate that the remote control failed to add the associated device (the association group has already added maximum quantity associated devices that it supports ). LED blinks 5 times to indicate that the remote control added the associated device successfully. LED blinks 8 times to indicate that the remote control removed the associated device successfully.
To remove all associated devices in an association group on the remote control directly:
- Press and hold down both buttons and of Group 2 over 3 seconds, LED indicator turns on.
- Click OFF button of any group on the remote control 5 times continuously within 7 seconds to remove all associated devices of this group, LED indicator blinks 8 times to indicate that the associated devices are removed successfully.
Operating the device
- Short press or press and hold down any button to send scene activation command to association group 1 using Command Class “Central Scene Notification V3”.
- Short press / button of Group 2, send ON/OFF command to all associated devices of Association Group 2.
- Press and hold down / button of Group 2, send light intensity increase/decrease command to all associated devices of Association Group 2.
- Short press / button of Group 3, send ON/OFF command to all associated devices of Association Group 3.
- Press and hold down / button of Group 3, send light intensity increase/decrease command to all associated devices of Association Group 3.
- Short press / button of Group 4, send ON/OFF command to all associated devices of Association Group 4.
- Press and hold down / button of Group 4, send light intensity increase/decrease command to all associated devices of Association Group 4.
- Short press / button of Group 5, send ON/OFF command to all associated devices of Association Group 5.
- Press and hold down / button of Group 5, send light intensity increase/decrease command to all associated devices of Association Group 5.
How to communicate with the device
The remote control is under sleepy mode for most of the time to save battery
power. It can not receive wireless command under sleepy mode. Before the
gateway interacts data with the remote, the remote control shall be activated
manually first. Short press any button to activate the remote control for 3s,
and press and hold down and buttons of Group 2 over 1 second to activate the
remote control for 7s.
Node Information Frame
The Node Information Frame is the business card of a Z-Wave device. It
contains information about the device type and the technical capabilities. The
inclusion and exclusion of the device is confirmed by sending out a Node
Information Frame. Beside this it may be needed for certain network operations
to send out a Node Information Frame.
How to send out Node Information Frame:
Set the wall controller into inclusion/exclusion mode: and press and hold down
and buttons of Group 2 over 3 seconds, LED indicator turns on to indicate the
wall controller has already sent out Node Information Frame, the user can
repeat the operation to set the wall controller to quit “inclusion/exclusion
mode”.
Technical Data
Battery Type | 1*CR2450 |
---|---|
Frequency | 868.42 MHz |
Wireless Range | up to 100 m outside, on average up to 20 m inside buildings |
SDK | 6.71.01 |
Explorer Frame Support | Yes |
Device Type | Wall Controller |
Generic Device Class | Switch Remote |
Specific Device Class | Switch Remote Multilevel |
Routing | No |
FLiRS | No |
Z-Wave Plus Info
Parameter | Value |
---|---|
Z-Wave Plus Version | 1 |
Role Type | Slave Portable |
Node Type | ZWAVEPLUS |
Installer Icon Type | 0x0b00 (ICON_TYPE_GENERIC_REMOTE_CONTROL_SIMPLE) |
User Icon Type | 0x0b00 (ICON_TYPE_GENERIC_REMOTE_CONTROL_SIMPLE) |
Manufacturer Specific
Parameter | Value (hex) |
---|---|
Manufacturer ID | 0x0330 |
Product Type ID | 0x0003 |
Product ID | 0xa305 |
SUPPORTED COMMAND CLASS
- COMMAND_CLASS_ZWAVEPLUS_INFO_V2
- COMMAND_CLASS_ASSOCIATION_V2
- COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
- COMMAND_CLASS_CENTRAL_SCENE_V3
- COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
- COMMAND_CLASS_TRANSPORT_SERVICE_V2
- COMMAND_CLASS_VERSION_V2
- COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
- COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
- COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
- COMMAND_CLASS_POWERLEVEL_V1
- COMMAND_CLASS_BATTERY_V1
- COMMAND_CLASS_SECURITY_V1
- COMMAND_CLASS_SECURITY_2_V1
- COMMAND_CLASS_WAKE_UP_V2
- COMMAND_CLASS_SUPERVISION_V1
Controlled Command Classes
- COMMAND_CLASS_CENTRAL_SCENE_V3
- COMMAND_CLASS_BASIC_V2
- COMMAND_CLASS_SWITCH_MULTILEVEL_V4
- Multi Channel V3
- Security_V1
- Security_2_V1
Installation
Remove battery insulator
-
Use tool to open the silicone gel battery cover
-
Pull out the battery insulator
-
Install the silicone battery cover back
Install the controller to wall(2 methods)
Method 1: Stick 3M glue on the back of the bracket and then stick the
bracket to the wall
Method 2: Screw the bracket to the wall
After the bracket is fixed,clip the frame and control part to the bracket in
sequence
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>