ROBB 70110005 Zigbee Smart Plug Instruction Manual
- June 12, 2024
- ROBB
Table of Contents
Zigbee Smart Plug
Important: Read All Instructions Prior to Installation
Function introduction
Product Data
Zigbee profile | 0x0104(ZHA) |
---|---|
Device ID | 0x000A(Plug-in Unit) |
Radio Frequency | 2.4GHz |
Input Voltage | AC200-240V, 50/60Hz |
Max. Load | 16A |
Over Current Protection | 16.1A |
Operating temperature | 0 to 40°C |
Relative humidity | 8% to 80% |
Dimensions | 114.8×54.8×74.7(mm) |
LED Indicator State | Definition (16.1A Over Current) |
--- | --- |
Flashes red slowly | Over current |
Stays solid orange | Load power > 2200W |
Stays solid yellow | Load power 2001-2200W |
Stays solid green | Load power 1501-2000W |
Stays solid cyan | Load power 1001-1500W |
Stays solid blue | Load power <= 1000W |
Flashes purple slowly | Firmware updating via OTA |
Stays solid white at a low brightness | Load switched off |
- ZigBee smart plug based on latest ZigBee 3.0 protocol
- Enables to control ON/OFF of the load, supports max. 16 scenes
- ZigBee end device that supports Touchlink commissioning
- Supports find and bind mode to bind a ZigBee remote
- Supports zigbee green power and can bind max. 20 zigbee green power switches
- Supports temperature measurement
- Supports over current protection and power metering, enables to report power consumption to gateway
- Waterproof grade: IP20
Safety & Warnings
- DO NOT install with power applied to device.
- DO NOT expose the device to moisture.
Operation
1. Plug the smart plug into AC power source.
2. This ZigBee device is a wireless receiver that communicates with a
variety of ZigBee compatible systems. This receiver receives and is controlled
by wireless radio signals from the compatible ZigBee system.
3. Zigbee Network Pairing through Coordinator or Hub (Added to a Zigbee
Network)
Step 1: Remove the device from previous zigbee network if it has already
been added to, otherwise pairing will fail. Please refer to the part “Factory
Reset Manually”.
Step 2: From your ZigBee Controller or hub interface, choose to add
lighting device and enter Pairing mode as instructed by the controller.
Step 3: Short press “Program” button 5 times continuously to set the
device to network pairing mode, LED indicator will flash white fast.
4. TouchLink to a Zigbee Remote
Step 1: Short press “Prog” button 4 times (Or re-power on the device 4
times) to start Touchlink commissioning, 180S timeout. Once timeout, repeat
the operation.
Note:
- Directly TouchLink (both not added to a ZigBee network), each device can link with 1 remote.
- TouchLink after both added to a ZigBee network, each device can link with max. 30 remotes.
- To control by both gateway and remote, add remote and device to network first then TouchLink.
- After TouchLink, the device can be controlled by the linked remotes.
5. Removed from a Zigbee Network through Coordinator or Hub Interface
6. Factory Reset Manually
Step 1: Short press the “program” button 5 times continuously, the plug
will enter into network pairing mode.
7. Factory Reset through a Zigbee Remote (Touch Reset)
Note: Make sure the device already added to a network, the remote added
to the same one or not added to any network.
Step 1: Re-power on the device to start TouchLink Commissioning, 180
seconds timeout, repeat the operation.
8. Find and Bind Mode
Step 1: Short press “Prog.” button 3 times to start Find and Bind mode
(LED indicator flashes white slowly) to find and bind target node, 180 seconds
timeout, repeat the operation.
Note: Make sure both the device and remote are added to the same gateway
that supports find and bind.
9. Learning to a Zigbee Green Power Switch
Step 1: Short press “Program” button 4 times to start Learning to GP
switch mode (LED indicator flashes twice), 180 seconds timeout, repeat the
operation.
10. Delete Learning to a Zigbee Green Power Switch
Step 1: Short press “Program” button 3 times to start delete Learning to
GP switch mode (LED indicator flashes slowly), 180 seconds timeout, repeat the
operation.
11. Setup a Zigbee Network & Add Other Devices to the Network (No Coordinator
Required)
Step 1: Short press “Program” button 4 times to enable the device to
setup a zigbee network (LED indicator flashes white twice) to discover and add
other devices, 180 seconds timeout, repeat the operation.
Step 2: Set another device or remote or touch panel into network pairing
mode and pair to the network, refer to their manuals.
Step 3: Pair more devices and remotes to the network as you would like,
refer to their manuals.
Step 4: Bind the added devices and remotes through Touchlink so that the
devices can be controlled by the remotes, refer to their manuals.
Note:
- Each added device can link and be controlled by max. 30 added remotes.
- Each added remote can link and control max. 30 added devices.
12. ZigBee Clusters the device supports are as follows:
Input Clusters
- 0x0000: Basic
- 0x0003: Identify
- 0x0004: Groups
- 0x0005: Scenes
- 0x0006: On/off
- 0x0702: Simple Metering
- 0x0b04: Electrical Measurement
- 0x0b05: Diagnostics
- 0x1000: ZLL Commissioning
- 0x0402: temperature measurement
Output Clusters
- 0x0003: Identify
- 0x0019: OTA
13. OTA
The device supports firmware updating through OTA, and will acquire new
firmware from zigbee controller or hub every 10 minutes automatically.
Read User Manual Online (PDF format)