TESLA 479755 Smart Dehumidifier XL User Manual

June 4, 2024
Tesla

TESLA 479755 Smart Dehumidifier XL

TESLA SMART
DEHUMIDIFIER XL
USER MANUAL

IMPORTANT MATTERS

Please read the user manual carefully before use and keep it for future reference.
Danger

  1. Please keep the product away from water, other liquids, or flammable detergents, to avoid electric shock and fire.
  2. Do not spray any flammable materials such as pesticides or perfume around the product.

Warning Improper operation may cause fatal or serious injury.
Warning Improper operation may cause injury or damage to your house and property, etc.

| Forbid
---|---
|  Disassembly Prohibited
| No Water
| Please Strictly Follow
| Keep Away from Fire Source

The meanings of icons in this manual and on this machine are as shown above.
Safety Warning

  1. Do not plug/unplug the power cord to turn on/off the machine.
    Otherwise, it may cause fire/electric shock accidents.

  2. Do not use an extended power cord or multi-socket terminal board.
    Otherwise, it may cause fire, electric shock, or malfunction.

  3. Do not damage or refit the power cord or plug.
    1. Do not refit, tie, twist, bend or heat the power cord. Do not place it under heavy objects or bend it at the part near the plug when using it.
    2. Fire or electric shock may be caused due to damage. (Keep the pets away from the power cord to avoid scratches or bites). If the flexible power cord is damaged, it must be replaced by a professional from the manufacturer, its maintenance department, or a similar department to avoid danger.TESLA 479755
Smart Dehumidifier XL - fig1

  4. Do not put fingers or sticks into the air inlet or outlet.
    Injury or malfunction may be caused as the fan inside the machine rotates at high speed.

  5. Do not attempt to repair, disassemble or refit this machine.
    Otherwise, it may cause fire and/or electric shock accidents. For maintenance matters, please consult the original purchase point.

  6. Do not place the machine near a heating device (stove or heater, etc.).
    Otherwise, the resin may melt and cause a fire.

  7. Please wipe the dust on the power plug, and then plug it securely.
    If the plug is not properly plugged in, dust will accumulate in the gap, thus causing fire and/or electric shock accidents.

  8. Please use the power socket compatible with the rated voltage of the product.
    The use of a non-rated AC socket may cause illness or unpredictable accidents.

  9. In case of any abnormality (such as a burning odor), please turn off this machine and unplug the power cord.
    If you continue to operate the machine under abnormal conditions, it may cause fire, electric shock, or malfunction. At this time, please consult the original purchase point.

  10. Please read the installation instructions carefully before installing this machine.
    Otherwise, it may cause loss due to improper operation.

  11. Do not move the machine while it is running.

  12. Do not use clothes, curtains, and other items to cover the air inlet and outlet or air deflector.
    Otherwise, it will cause poor air circulation and fire or heat.

  13. Do not stand on or lean against the dehumidifier.
    For this machine may overturn and cause injury.

  14. Do not place vases and other water containers on the dehumidifier.
    Otherwise, water leakage into the interior will damage the electrical insulation and cause electric shock or fire accidents due to a short circuit.

  15. Do not lean the machine against obstacles or walls.
    Please keep a distance of more than 20cm from the machine to its rear and to its left and right, and a distance of more than 50cm from the machine to its top and to its front.

  16. Do not use the dehumidifier in narrow places such as wardrobes and furniture.
    Otherwise, it will cause poor air circulation and fire or heat.

  17. Do not make the air supply outlet directly face toward the combustion device.
    Otherwise, it may cause incomplete combustion of the combustion device.

  18. Do not use the dehumidifier in high temperature or flammable and explosive places.
    Drugs and solvents emitted into the air may damage this machine, thus resulting in performance degradation.

  19. Please power off the machine before cleaning and maintenance (Do not use alcohol, gasoline, benzene, and other chemical solvents).
    Otherwise, it may cause electric shock accidents.

  20. Do not drain water continuously if the temperature around the water pipe is below zero.
    Otherwise, the water in the pipe may freeze and prevent the water from flowing out of the tank, thus resulting in water leakage out of this machine and damage to surrounding objects.

  21. Do not remove the foamed plastics from the floating body.
    Otherwise, the floating body will not be able to detect the water level, resulting in water leakage, and may damage surrounding objects or cause electric shock or leakage accidents.

  22. Do not clean this machine with water. Do not use this machine in places where it may come into contact with water.
    The machine may leak electricity when it comes into contact with water, which may cause fire or electric shock accidents.

  23. Do not make the air supply outlet directly face people.
    Otherwise, it may cause discomfort and dehydration if the body is exposed to air for a long time.

  24. Please unplug the power cord, empty the tank to air dry it, and then place it for two days when the machine is not in use for long time.
    Otherwise, it may cause fire or electric shock accidents due to electric leakage.

  25. Please place this machine in a stable horizontal place.

  26. Please empty the tank first, and then hold the handle firmly to move this machine.TESLA 479755 Smart Dehumidifier XL - fig9
    The use of a non-rated voltage AC socket may cause fire and/or electric shock accidents.

  27. In case of continuous drainage, please be sure to place the water pipe well, so that it can drain freely.
    Otherwise, the water in the tank may leak out and damage the surrounding objects.

  28. If it is drained continuously or used unattended for a long time, please check it every two weeks.
    Water leakage.

PRODUCT OVERVIEW

TESLA 479755 Smart Dehumidifier XL - fig10

Specifications

Model Virgo
Dimension 295x295x560mm
Weight 12Kg
Noise <45dB
Effective Area <30m2

TESLA 479755 Smart Dehumidifier XL - fig11

PRODUCT OVERVIEW
Power ON-OFF Button:
Control power on/off
Fan Speed/Child Lock Button:
Set the running fan speed of the machine: High (H), Low (L), Sleep. Long press 3 seconds to activate or cancel the child lock function.
Humidity Setting Button:
40%, 60%, 80%, Cont (continuous dehumidification). Set the target environmental humidity.
Timer Button:
Set the shutdown time: 2H, 4k 8H.

WIFI Indicator:
The flashing indicator indicates that the machine is networking (Only the machine with the WIFI function will have this indicator).
Timer Indicator:
When the indicator is on, it corresponds to the scheduled shutdown time of the machine, with 2H, 4H, and 8H optional.
Relative Humidity Display:
Display the ambient humidity value of the machine. It will display LO if the humidity is smaller than 40%RH, and display HI if the humidity is greater than 80%RH.
Child Lock Indicator and Sleep Indicator:
When the water tank full indicator is on, the machine will stop. All buttons are locked.
Running Indicator:
When the running indicator is on, it indicates that the machine is working.
Humidity Button:
Set the humidity value in 40%, 60%, 80% or Cont.
Fan Speed Indicator:
When the corresponding indicator light is on, it indicates that the Fan is running, with H, L, and Sleep options.
Relative Humidity Indicator:
When the relative humidity setting button is switched, the corresponding relative humidity indicator will be on, and the machine will dehumidify according to the set relative humidity value (40%, 60%, 80%, Cont).
PRODUCT OVERVIEW

  1. Plug the machine power cord into the power socket, and then plug it into the power supply. The buzzer will beep three times.
  2. Press the power ON/OFF button. After the buzzer beeps once, the machine will enter the continuous dehumidification state. In this state, the running indicator and the continuous dehumidification function indicator are on, the double-digit display screen shows the ambient humidity value, and the fan motor runs.

Dehumidification Humidity Settings

Power Button

  1. The machine is in the normal running state when the running indicator is on.
  2. Four humidity setting modes (40%, 60%, 80%, Cont) are available, and the indicator will be on when the machine runs in the corresponding mode.

USE INSTRUCTION

Air Quality Indicator (Optional): After the machine is powered on for the 30s, it will be in the reservation state. At this time, the four full-color lights at the bottom of the control panel will gradually change for the 30s (in the order of blue, cyan, green, yellow, orange, red, and purple).
Air quality control results are as follows:

  • The ambient light turns blue when the air quality is good.
  • The ambient light turns yellow when the air quality is normal.
  • The ambient light turns red when the air quality is poor.
    When the machine is in sleep mode, the full-color lights go out and the machine enters sleep mode.

WIFI OPERATION (OPTIONAL)

  1. Preparation for use
    • Tesla Smart is available for both iOS and Android OS. Search the name, Tesla Smart’ in App Store or Android Market, or scan the QR-Code to download the App and register or log in to your account.
    • Make sure that the smartphone is connected to the 2.4Ghz network.TESLA
479755 Smart Dehumidifier XL - qr code
    http://tsl.sh/app

  2. Connect the device
    • Open the Tesla Smart app and click the “+” sign to Add a new device
    • Select dehumidifiers – Tesla Smart Dehumidifier XL
    • Please follow the instructions to add the Tesla Smart Switch step by step

  3. Control Dehumidifier
    • Control dehumidifier with APP

Reset
• Long press and hold the dehumidifier Wifi/timing button until the LED flashes to reset the dehumidifier and get into quickly configure mode.

INTELLIGENT DETECTION
High and Low Ambient Temperature Protection:

  1. When the temperature and humidity sensor at the machine air inlet detects that the current ambient temperature is greater than or equal to 42°C, the digital tube will keep flashing slowly and display „ L3″, and all loads will be turned off. At this time, the machine can be restored after the power is on again.
  2. When the temperature and humidity sensor at the machine air inlet detects that the current ambient temperature is less than or equal to 0°C, the digital tube will keep flashing slowly and display „ L4″, and all loads will be turned off. At this time, the machine can be restored after the power is on again.

Refrigerant Leakage Protection:
The compression dehumidifier will be subject to refrigerant leakage detection every 8min when it is working. If the suspected refrigerant leakage is detected five consecutive times, only C8 on the digital tube is flashing, and the compressor and the fan motor on the machine stop. At this time, all buttons do not work, and the buzzer will not beep.
Cautions:

  • When the machine is under refrigerant leakage protection, it is necessary to unplug the power cord from the power socket to unprotect and power it on again to start the machine.
  • If the protection is activated due to a malfunction of the machine, it can be used normally after troubleshooting (Power on again after unplugging the power cord).

Compressor Stop/Start Protection:
During the operation of the machine, when the whole machine is not powered down, the compressor, after shutdown, will be delayed for 3min before starting again (At this time, the wind speed is adjustable).
Category I: Within 3min from the last shutdown, the compressor is in the forced shutdown state, and it can be started only after it is beyond 3min from the last shutdown.
Category II : The compressor can be started immediately after it is beyond 3min from the last shut-down.
Cautions:
if the whole machine is powered down, the compressor can be started immediately after it is powered on again anytime.

If the machine is in dehumidification or refrigeration operation, you need to take out the tank and then put it back or turn it off and then turn it on again, and the dehumidification will not start until 3min later.
Water Tank Full Automatic Protection:

  1. When the machine is working, if the tank is full, the compressor and the fan motor will stop working, and only the tank full indicator will be on.
  2. Take out the tank and pour out the water.
  3. Put the tank back, and the machine will restart according to the state before the tank is full (Dehumidification will not start until 3min later).

Fault Detection of Temperature and Humidity Sensor:

  1. When the temperature sensor of the evaporator coil is in an open or short circuit state, the digital tube will display El and flash. At this time, the machine functions normally. The compressor will work for 30min first and then stop for 10min and repeat this cycle. It will return to normal automatically after troubleshooting.

Cautions:
When the temperature sensor of the evaporator copper tube of the machine is in an open or short circuit, the buttons of the machine can still operate normally. In this case, the machine can still work, but the effect will be slightly worse.
2. When the components of the temperature and humidity sensor are in an open or short circuit state or unable to connect, the digital tube will display E2 and flash. At this time, other buttons except the humidity button will function normally, and it will enter in the Cont mode by default. It will return to normal automatically after troubleshooting.
Fault Detection of Temperature and Humidity Sensor:

  1. When the temperature sensor of the evaporator coil is in an open or short circuit state, the digital tube will display El and flash. At this time, the machine functions normally. The compressor will work for 30min first and then stop for 10min and repeat this cycle. It will return to normal automatically after troubleshooting.

Cautions:
When the temperature sensor of the evaporator copper tube of the machine is in an open or short circuit, the buttons of the machine can still operate normally.
In this case, the machine can still work, but the effect will be slightly worse. 2. When the components of the temperature and humidity sensor are in an open or short circuit state or unable to connect, the digital tube will display E2 and flash. At this time, other buttons except the humidity button will function normally, and it will enter in the Cont mode by default. It will return to normal automatically after troubleshooting.
Automatic Defrosting:

  1. When the temperature sensor fixed on the evaporator copper tube detects that the temperature is less than -10°C, the machine will enter the automatic defrosting procedure. (The machine will start automatic defrosting after 30min of dehumidification) At this time, the digital tube will display HS, and the machine will automatically return to normal after the end of defrosting.
  2. When the frost on the evaporator surface has melted, and its temperature is greater than or equal to 2°C and the defrosting time is more than or equal to 10min, the defrosting action stops and the dehumidification function activates.

Filter Replacement Reminder:

  1. When the whole machine has been running for 2,200h in total, the power indicator will flash at the frequency of is/time, reminding us that the filter needs to be replaced. If the filter has been replaced, you can long press the power button to reset it.

Fault Detection of Temperature and Humidity Sensor:
When the power keeps on after pressing the ON/OFF button to shut down, the machine will remember how it worked before shutdown after pressing the ON/OFF button again. When the power is cut off after pressing the ON/OFF button to shut down, the machine will work in the initial default mode after pressing the ON/OFF button to power on again.
When the power is cut off while the machine is working, the machine will work in the initial default mode after pressing the ON/OFF button to power on again.

INTELLIGENT DETECTION

Wipe the tank and the body with a soft cloth and store the machine in a ventilated and dry environment to prolong its service life. (Do not use corrosive detergents)TESLA 479755 Smart Dehumidifier XL -
fig15

If the filter net is blocked by dust, the dehumidification effect will be worse. Please clean it every
2 weeks or so.

  1. Take out the filter net.
  2. Clean it with a vacuum cleaner.
  3. Install the filter net.

TESLA 479755 Smart Dehumidifier XL - fig16

INTELLIGENT DETECTION

When the machine needs to drain continuously, use a proper flexible rubber hose to connect to the drainage hole through the hole of the tank. When the machine is running continuously, the tank will not hold water. This machine can run continuously without causing shutdown protection because the tank is full of water.

  •  Extend the continuous drainage pipe from the continuous drainage outlet into the machine, and then insert the continuous drainage pipe from the tank port into the continuous drainage hole.
  • In case of continuous drainage, the drainage pipe should be placed flat on the ground. Any part of the drainage pipe should not be folded or warped, and the outlet end of the drainage pipe should not extend below the liquid level of other containers, otherwise, unsmooth drainage or even failure to drainage may occur.

TESLA 479755 Smart Dehumidifier XL - fig17

SPECIFICATIONS

Model Virgo-RCS12 (Y)-N7-1
Daily Dehumidification Capacity 12L/D(30 C,RH80%)
Nominal Dehumidification Capacity 0.29kg/h(27C, RH6O%)
Effective Area 18-30
Dehumidification Mode 40%,60%,80%,Cont
Water Tank Capacity 3.2L
Moving Mode Portable
Noise Decibel 45db(A)
Timing 2-4-8 h
Wind Speed H-M Sleep
Refrigerant R290
Rated Voltage 220/50HZ
Rated Power 158W
Maximum Power 205W
Net Weight 12kg
Gross Weight 13KG
Dimension 295x295x560

FUNCTIONS

Power Off Memory: Standard configuration
Tank Full Alarm: Standard configuration
Windshield: Standard configuration
Purify: Optional
WIFI: Optional
Casters: Optional

INFORMATION ABOUT DISPOSAL AND RECYCLING
This product is marked with the symbol for a separate collection. The product must be disposed of in accordance with the regulations for disposal of electrical and electronic equipment (Directive 2 012/19/EU on waste electrical and electronic equipment). Disposal together with regular municipal waste is prohibited. Dispose of all electrical and electronic products in accordance with all local and European regulations at the designated collection points which hold the appropriate authorization and certification in line with the local and legislative regulations. Correct disposal and recycling help to minimize impacts on the environment and human health. Further information regarding disposal can be obtained from the vendor, authorized service center, or local authorities.
EU DECLARATION OF CONFORMITY
Hereby, Witty, s.r.o declares that the radio equipment type TSL-AC-VIRGO is in compliance with EU directives. The full text of the EU declaration of conformity is available at the following internet address: teslasmart.com/declaration
Connectivity: Wi-Fi 2,4 GHz IEEE 802.11b/g/n
Frequency band: 2.412 – 2.472 GHz
Max. radio-frequency power (EIRP): < 20 dBm

Manufacturer
Tesla Global Limited
Gee Chang Industrial Building,
121 Des Voeux Road Central
852 00 Hong Kong
www.teslasmart.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals