levenhuk MED 30 Microscopes User Manual
- June 12, 2024
- levenhuk
Table of Contents
levenhuk MED 30 Microscopes
Product Information:
- Product Name: Levenhuk MED 30 Microscopes
- Models:
- Levenhuk MED 30B
- Levenhuk MED 30T, D30T, D30T LCD
Components:
The Levenhuk MED 30 Microscopes include the following components:
- Eyepiece
- Binocular/trinocular eyepiece head
- Arm
- Revolving nosepiece
- Objective
- Stage
- Mechanical scale
- Brightness adjustment knob
- Aperture diaphragm adjustment screws
- Coarse focusing knob
- Fine focusing knob
- Condenser
- Collector
- Stage moving knob (right/left)
- Stage moving knob (back/forth)
- Illumination on/off button (not shown)
- Beam splitter (trinocular models only)
- Diopter adjustment ring
- Binocular/trinocular head locking screw
- Third eyepiece tube (trinocular models only)
- Slot for a plain polarization device (the device is not included in the kit)
Digital Camera:
The Levenhuk MED D30T model comes with a digital camera (fig. 2a), while
the Levenhuk MED D30T LCD model comes with a digital camera with an LCD screen
(fig. 2b). The digital camera is installed to the third eyepiece tube and
enables observing specimens on the screen, taking photos and videos, and
saving the images for future reference.
Product Usage Instructions:
Fuse Replacement:
- Unplug the microscope from a power source.
- Open the fuse holder located on the back of the microscope body with a flat head screwdriver.
- Remove the old fuse.
- Install a new fuse. Only use the appropriate types of fuses.
- Close the fuse holder.
Using the Digital Camera:
The digital camera is installed to the third eyepiece tube.
Follow the instructions provided with the camera to observe specimens on the
screen, take photos and videos, and save the images for future reference.
Power Supply:
The microscope can be powered using the AC adapter included with the
Levenhuk MED D30T LCD model. Ensure that the microscope is properly connected
to the power source before use.
Additional Information:
For additional specifications and technical details, refer to the product
manual or visit the manufacturer’s website.
Components
- Eyepiece
- Binocular/trinocular eyepiece head
- Arm
- Revolving nosepiece
- Objective
- Stage
- Mechanical scale
- Brightness adjustment knob
- Aperture diaphragm adjustment screws
- Coarse focusing knob
- Fine focusing knob
- Condenser
- Collector
- Stage moving knob (right/left)
- Stage moving knob (back/forth)
- Illumination on/off button (not shown)
- Beam splitter (trinocular models only)
- Diopter adjustment ring
- Binocular/trinocular head locking screw
- Third eyepiece tube (trinocular models only)
- Slot for a plain polarization device (the device is not included in the kit)
2a. Levenhuk MED D30T
- Digital camera
- USB cable
- Installation CD
2b. Levenhuk MED D30T LCD
- Digital camera with LCD screen
- AC adapter
General Information
Read the user manual carefully before you start working with a microscope. Levenhuk MED Series biological microscopes are safe for health, life and property of the consumer and the environment when properly used, and meets the requirements of international standards. These microscopes are designed for observing transparent objects in the transmitted light using the bright field method. They perform well in clinical research and tests; teaching demonstrations; bacterioscopy and cytology in medical and health establishments, laboratories, universities; and may be used for scientific research in agriculture and microbiology.
Microscope assembly
- Unpack the microscope carefully and place it on a flat surface.
- Remove the plastic bags and dustproof cover of the eyepiece head.
- Install the binocular or trinocular head and tighten the locking screw.
- Inspect all the items included in the kit and define their purpose.
- Connect the power cord to the microscope and plug it in.
Use
Please refer to the fig. 1а (binocular model) and fig. 1b (trinocular model).
-
Turn on the power and the illumination will turn on. Set the brightness at approximately 70%. Place the specimen on the stage. Make sure the clips hold the specimen firmly in place.
-
Iris diaphragm should be adjusted in accordance with numerical aperture of a lens. The best practice is to make the iris diaphragm slightly smaller than the aperture of the selected lens. Open or close the iris diaphragm using the adjustment screws. If the adjustment screw is turned to the right, the iris diaphragm is fully open. Note: The diaphragm is not intended for adjusting the brightness of the illumination. To adjust the brightness, use the brightness adjustment knob.
-
Place the necessary filter on top of the collector.
-
To change the objective magnification, turn the revolving nosepiece until it clicks.
-
Make sure that the lens does not touch the sample when adjusting the focus: Rotate the coarse focus knob until the specimen is about 3.175mm (1/8”) away from the lens.
-
Looking into the eyepiece, slowly turn the coarse focusing knob until you can see the image of the observed specimen. Turn the fine focusing knob to make the image clear. The fine focusing mechanism allows you to focus on the observed specimen while using high magnifications.
-
When you use an oil immersion objective, the space between the specimen and the lens should be filled with immersion oil.
Raise the condenser to the upper position and put a drop of oil on the lens and on the cover glass of the specimen. Move the revolving nosepiece back and forth to get rid of air bubbles in the oil. Then, fix the objective lens in its working position.
Make sure that oil fills the entire space between the objective lens and the specimen. After use, wipe the lens dry. -
To adjust the position of the mechanical scale, turn the coarse focusing knob in a clockwise direction if you want to fix the position of the mechanical scale, or in a counterclockwise direction if you want to loosen it.
-
To place the specimen in the field of view, move the stage horizontally back and forth or left and right using the stage moving knobs.
-
Look through the right eyepiece with your right eye and adjust the image sharpness with the coarse and fine focusing knobs.
Then, look through the left eyepiece with your left eye and rotate the diopter adjustment ring to equalize the difference between your left and right eyes vision. Remember the setting for future use. Adjust the distance between the eyepiece tubes of the binocular head so that the image merges into a single circle. -
Trinocular models: You can install the digital camera to the third eyepiece tube. Use the beam splitter to send the light to the eyepieces or to the camera.
Fuse replacement
Unplug the microscope from a power source. Open the fuse holder located on the
back of the microscope body with a flat head screwdriver. Remove the old fuse
and install a new one. Only use the appropriate types of fuses. Close the fuse
holder.
Digital camera
Levenhuk MED D30T comes with a digital camera (fig. 2a), Levenhuk MED D30T LCD
comes with a digital camera with an LCD screen (fig. 2b). A digital camera is
installed to the third eyepiece tube and enables observing specimens on the
screen in exquisite detail and true color, taking photos and videos, and
saving the images for future reference.
Specifications
Product ID | 73996 | 73997 | 73998 | 73999 |
---|---|---|---|---|
Model | MED 30B | MED 30T | MED D30T | MED D30T LCD |
Type | biological/optical | biological/optical, digital | ||
Research method | bright field | bright field | ||
Magnification | 40—1000x | 40—1000x | ||
Interpupillary distance | 48—75mm | 48—75mm |
Eyepiece head
| binocular, 360° rotatable,
inclined at 30°
| trinocular, 360° rotatable,
inclined at 30°
| trinocular, 360° rotatable,
inclined at 30°
Optics material| optical glass with an anti-fungal coating| optical glass with
an anti-fungal coating
Eyepiece tube diameter| 30mm| 30mm
Third vertical eyepiece tube| —| 23.2mm| 23.2mm
Eyepieces| WF10x/22mm (2pcs)| WF10x/22mm (2pcs)
Eyepiece diopter adjustment| ±5D| ±5D
Objectives| Infinity SemiPlan:
4x, 10x, 40xs, 60xs, 100xs (oil)
| Infinity SemiPlan:
4x, 10x, 40xs, 60xs, 100xs (oil)
Revolving nosepiece| 5 objectives| 5 objectives
Stage moving range| 80/50mm| 80/50mm
Stage| double layer mechanical, 180x160mm,
with a mechanical scale
| double layer mechanical, 180x160mm,
with a mechanical scale
Focus system
| coaxial,
coarse (0.5mm) and fine (0.002mm),
with rack and pinion mechanism
| coaxial,
coarse (0.5mm) and fine (0.002mm),
with rack and pinion mechanism
Condenser| Abbe N.A. 1.25 iris diaphragm| Abbe N.A. 1.25 iris diaphragm
Body| metal| metal
Illumination| lower (3W LED with additional lens) with brightness adjustment|
lower (3W LED with additional lens) with brightness adjustment
Collector| Köhler illumination| Köhler illumination
Filters| blue, green, yellow| blue, green, yellow
Vial of immersion oil| +| +
Fuse| 2pcs| 2pcs
Power supply| 100—240V, via AC adapter| 100—240V, via AC adapter
Digital camera| —| 10Mpx| 5Mpx with
LCD screen
Camera power supply| —| DC 5V,
via USB 2.0 cable
| DC 12V/2A,
via AC adapter
Optional accessories (sold separately)
| infinity plan objectives: 4x, 10x, 20xs, 40xs, 60xs, 100xs (oil)|
infinity plan objectives: 4x, 10x, 20xs, 40xs, 60xs, 100xs (oil)
eyepieces (D 30mm): 5х, 12.5х, 16x, 20x| eyepieces (D 30mm): 5х, 12.5х,
16x, 20x
dark field condenser| dark field condenser
standard contrast device| standard contrast device
plain polarization device| plain polarization device
—| digital camera| —
Caution! Please remember that mains voltage in most European countries is 220—240V. If you want to use your device in a country with a different mains voltage standard, remember that use of a converter is absolutely necessary. The microscope must be grounded. Make sure that the main voltage matches the voltage indicated on the microscope body.
Care and maintenance
Never, under any circumstances, look directly at the Sun, another bright source of light or at a laser through this device, as this may cause PERMANENT RETINAL DAMAGE and may lead to BLINDNESS. Take necessary precautions when using the device with children or others who have not read or who do not fully understand these instructions. After unpacking your microscope and before using it for the first time check for integrity and durability of every component and connection. Do not try to disassemble the device on your own for any reason. For repairs and cleaning of any kind, please contact your local specialized service center. Protect the device from sudden impact and excessive mechanical force. Do not apply excessive pressure when adjusting focus. Do not overtighten the locking screws. Do not touch the optical surfaces with your fingers. To clean the device exterior, use only special cleaning wipes and special optics cleaning tools from Levenhuk. Do not use any corrosive or acetone-based fluids to clean the optics. Abrasive particles, such as sand, should not be wiped off lenses, but instead blown off or brushed away with a soft brush. Do not use the device for lengthy periods of time, or leave it unattended in direct sunlight. Keep the device away from water and high humidity. Be careful during your observations, always replace the dust cover after you are finished with observations to protect the device from dust and stains. If you are not using your microscope for extended periods of time, store the objective lenses and eyepieces separately from the microscope.
Store the device in a dry, cool place away from hazardous acids and other chemicals, away from heaters, open fire and other sources of high temperatures. When using the microscope, try not to use it near flammable materials or substances (benzene, paper, cardboard, plastic, etc.), as the base may heat up during use, and might become a fire hazard. Always unplug the microscope from a power source before opening the base or changing the illumination lamp. Regardless of the lamp type (halogen or incandescent), give it some time to cool down before trying to change it, and always change it to a lamp of the same type. Always use the power supply with the proper voltage, i.e. indicated in the specifications of your new microscope. Plugging the instrument into a different power outlet may damage the electric circuitry of the microscope, burn out the lamp, or even cause a short circuit. Children should use the device under adult supervision only. Seek medical advice immediately if a small part or a battery is swallowed.
Levenhuk International Lifetime Warranty
All Levenhuk telescopes, microscopes, binoculars and other optical products,
except for accessories, carry a lifetime warranty against defects in materials
and workmanship. Lifetime warranty is a guarantee on the lifetime of the
product on the market. All Levenhuk accessories are warranted to be free of
defects in materials and workmanship for six months from date of retail
purchase. Levenhuk will repair or replace such product or part thereof which,
upon inspection by Levenhuk, is found to be defective in materials or
workmanship. As a condition to the obligation of Levenhuk to repair or replace
such product, the product must be returned to Levenhuk together with proof of
purchase satisfactory to Levenhuk.
For further details, please visit our web site:
www.levenhuk.com/warranty
If warranty problems arise, or if you need assistance in using your product,
contact the local Levenhuk branch.
The original Levenhuk cleaning accessories
Levenhuk Cleaning Pen LP10
Removes dust with a brush
The soft tip is treated with a special cleaning fluid that removes greasy
stains Does not damage optical coatings of the lenses Leaves no smudges or
stains
Levenhuk Worldwide:
USA: www.levenhuk.com
Levenhuk USA: 928 E 124th Ave. Ste D, Tampa, FL 33612, USA, +1 813 468-3001,
contact_us@levenhuk.com
Levenhuk Europe: V Chotejně 700/7, 102 00 Prague 102, Czech Republic, +420
737-004-919, sales-info@levenhuk.cz
Levenhuk® is a registered trademark of Levenhuk, Inc.
© 2006—2022 Levenhuk, Inc. All rights reserved.
20220523
References
- Levenhuk’s Official Finland Website!
- Levenhuk’s official website in USA
- Levenhuk’un Türkiye’deki resmi web sitesi
- Официален уебсайт на Levenhuk в България
- Доживотна гаранция на Levenhuk – Официален уебсайт на Levenhuk в България
- Levenhuk’s official website in USA
- Levenhuk Limited Warranty – Levenhuk’s official website in USA
- Oficiální webové stránky Levenhuk pro Českou republiku
- Doživotní záruka společnosti Levenhuk – Oficiální webové stránky Levenhuk pro Českou republiku
- Die offizielle Website von Levenhuk in Deutschland
- Levenhuk Lebenslange Garantie – Die offizielle Website von Levenhuk in Deutschland
- Web oficial de Levenhuk en España
- Garantía internacional de por vida Levenhuk – Web oficial de Levenhuk en España
- Levenhuk’s official website in Europe
- Levenhuk Lifetime Warranty – Levenhuk’s official website in USA
- A Levenhuk élettartamra szóló szavatossága – A Levenhuk hivatalos magyarországi weboldala
- Levenhuk’s official website in Europe
- Compra strumenti di misura e apparecchiature ottiche – Sito web ufficiale di Levenhuk in Italia
- SkyHunters
- Levenhuk’s official website in Europe
- Oficjalna witryna internetowa Levenhuk w Polsce
- Gwarancja bezterminowa Levenhuk – Oficjalna witryna internetowa Levenhuk w Polsce
- Поддержка - Гарантийное обслуживание Левенгук - Levenhuk Russia
- Predajňa optických prístrojov | SonataOptics.sk
- Интернет-магазин оптических приборов
- Levenhuk’s official website in Europe
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>