Description
The device is a standalone access control and proximity card reader which supports EM & MF card types. It builds-in STC microprocessor, with strong anti-interference ability, high security and reliability, powerful function and convenient operation. It’s widely used in high-end buildings, residential communities and other public places.
Features
- Ultra-low Power: Standby current is less than 30mA
- Wiegand Interface: WG26 or WG34 input and output
- Searching time: Less than 0.1s after reading card
- Backlight keypad: Operate easily at night
- Doorbell interface: Support external wired doorbell
- Access wavs: Card. Pin code. Card & Pin code
- Independent codes: Use codes without related card
- Change codes: Users can change codes by themselves
- Delete users by card No.: The lost card can be delete by keyboard
Specifications
- Working Voltage: DC12-24V
- Card Reading Distance: 2 ~ 5cm
- Working Temperature: 40°C~60°C
- Lock output load: 53A
- Standby Current: 530mA
- Capacity: 2000 users
- Working Humidity: 10% ~90%
- Door Relay time: 0~99S (Adjustable)
Installation
Drill hole according to the size of the device and fix the back shell with the equipped screw. Thread the cable through the cable hole. connect the wires according to your required function, and wrap the unused wires to avoid short circuit. After connecting the wire, install the machine. (as show below)
Wiring
Color/ID/Description
- Green: DO/Wiegand Input(Wiegand Output in Card Reader Mode)
- White: D1/Wiegand Input(Wiegand Output in Card Reader Mode)
- Yellow: OPEN /Exit Button input terminal
- Red: +12V/ 12V + DC Regulated Power Input
- Black: GND/12V – DC Regulated Power Input
- Blue: NO/Relay normally on terminal
- Purple: COM/Relay Public terminal
- Orange: NC/ Relav normally-off terminal
- Pink: BELL A /Doorbell button one terminal
- Pink: BELL B /Doorbell button to the other terminal
Diagram
Common Power Supply
Special Power Supply
Reader Mode
Sound & Light indication
Advance setting
After each programming step finished, need to press * to out off programming mode.
Master Card Operation
Add Card
- Read master add card
- Read the 1st user card
- Read the 2nd user card
- Read master add card
Note: The master add card is used to add card users continuously and quickly.
When you read the master add card at the first time, you will hear short “BEEP” sound twice and the indicator light turns orange, it means you have entered into add user programming. When you read the master add card at the second time, you will hear long “BEEP” sound once and the indicator light turns red, it means you have exited the add user programming.
Delete Card
- Read master delete card
- Read the 1st user card
- Read the 2nd user card
- Read master delete card
Note: The master delete card is used to delete card users continuously and quickly.
When you read the master delete card at the first time, you will hear short “BEEP” sound twice and the indicator light turns orange, it means you have entered into delete user programming. When you read the master delete card at the second time, you will hear long “BEEP” sound once, the indicator light turns red, it means you have exited the delete user programming.
Data Backup Operation
Example: Backup the data of machine A to machine B
The green wire and white wire of machine A connects with the green wire and white wire of machine B correspondingly, set B for receiving mode at first, then set A for sending mode, the indicator light turns green flash during the data backup, data backup is successful when indicator light turns red.
Read User Manual Online (PDF format)