safire SF-AC105 Standalone Access Control User Manual

June 12, 2024
safire

safire SF-AC105 Standalone Access Control User Manual

1.lntroduction

The series of product is a new generation of multi-functional standalone access control. It adopts new ARM core 32-bit microprocessor design, which is powerful, stable and reliable. It contains
reader mode and standalone access control mode etc .. It’s widely applied to different occasions, such as office, residential communities, villa etc ..

2.Features

3.Technical Specifications

4.lnstallation

  • Remove the back cover from the keypad using the supplied special screw driver
  • Drill 2 holes on the wall for the self-tapping screws and hole for the cable
  • Put the supplied rubber bungs to into the two holes
  • Fix the back cover firmly on the wall with 2 self-tapping screws
  • Thread the cable through the cable hole
  • Attach the keypad to the back cover. (as following illustration)

5.Wiring

6.Diagram

6.1 Common Power Supply

Note: The door contact and alarm function are optional

6.2 Special Power Supply

Note: The door contact and alarm function are optional

6.3 Reader Mode

7.Sound and Light Indication

8.Admin Menu

8.1 Standalone Mode Settings

Device Management

Access Ways

Advanced Settings

8.2 Reader Mode Settings

9.Admin Operation

9.1 Add Users

Read ad min add card Read the 1st user card Read the :zm user card Read admin add card

Note: The ad min add card is used to add card continuously and quickly. When you read the ad min add card at the first time, you will hear short “BEEP” sounds twice and the indicator light turns orange, it means you have entered into add user programming, when you read the admin add card at the second time, you will hear long “BEEP” sound once and the indicator light turns red, it means you have exited the add user programming.

9.2 Delete Users

Note: The admin delete card is used to delete card continuously and quickly. When you read the ad min delete card at the first time, you will hear short “BEEP” sounds twice and the indicator light turns orange, it means you have entered into delete user programming, when you read the admin delete card at the second time, you will hear long “BEEP” sound once, the indicator light turns red, it means you have exited the delete user programming.

10. Other Operation

10.1 Remove Alarm

Read valid card or ~P-ras-s ad~m- in- -cod-e#~
Note: When the alarm is activated, users can remove the alarm by reading a valid card or pressing valid admin code.

10.2 Reset to Factory Default

Users can reset to the factory default when the admin code is forgotten, or the default settings have been modified disorderedly, operations as below: Power off, press and hold the exit button continuously, power on, release the exit button until
hearing beep sound twice, the admin code has been reset to 999999, factory default settings are successful.
Note: Registered user data won’t be deleted when reset to factory default.

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

safire User Manuals

Related Manuals