Gude GP 6035 Water Pump Instruction Manual

June 12, 2024
Gude

Gude GP 6035 Water Pump

Gude-GP-6035-Water-Pump-PRODUCT

OVERVIEW

Gude-GP-6035-Water-Pump-FIG-1 \(1\)

INSTRUCTION

Gude-GP-6035-Water-Pump-FIG-1 \(2\) Gude-
GP-6035-Water-Pump-FIG-1 \(5\) Gude-GP-6035
-Water-Pump-FIG-1 \(6\)

The pump must not in any case run without fillings.

INSTALLATION

Gude-GP-6035-Water-Pump-FIG-1 \(3\) Gude-
GP-6035-Water-Pump-FIG-1 \(7\) Gude-GP-6035
-Water-Pump-FIG-1 \(8\)

TEMPERATURE

Gude-GP-6035-Water-Pump-FIG-1 \(4\)

Technical Data

Garden pump GP 6035

  • Service connection: 230 V/ 50 Hz

  • Motor output P1 ………………………………………………………………………………………………………………………………………………….600 W

  • Max. delivered quantity ………………………………………………………………………………………………………………………………….3200 l/h
    Max. head of delivery …………………………………………………………………………………………………………………………………………..35 m

  • Max. suction head ……………………………………………………………………………………………………………………………………………………7 m

  • Max. Water temperature ………………………………………………………………………………………………………………………………………35° C

  • Hose connection ……………………………………………………………………………………………………………………………………………………1“ IG

  • Degree of protection ……………………………………………………………………………………………………………………………………………. IPX4

  • Weight ………………………………………………………………………………………………………………………………………………………………….. 5,3 kg

  • Sound power level ……………………………………………………………………………………………………………………………………………… 83 dB

Read and understand the operating instructions before using the appliance. Abide by all the safety measures stated in the service manual. Act responsibly toward third parties. In case of any doubts about connection and operation refer please to our customer center

Specified Conditions Of Use

The pump is solely used for drainage and for pumping into and out of containers in the house, garden, farm, and agriculture and only for water. Respecting technical data and safety precautions. Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages. The pump is not suited for long-run operation (e.g. as a circulation pump in ponds or streams). When used in this manner, its service life is curtailedcorrespondingly. In these cases, then, use a time switch to secure sufficient idle periods between cycles of operation. Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.  Do not use the pump for drinking water! The pump must not be connected to the existing water-supply network as a pressure-boosting device. Never use the pump as a pool circulation pump.

Safety Instructions

WARNING! Electric shock! There is a risk of an injury caused by electric shock! This device is not intended for use by persons (including children) with limited physical, sensory or mental capabilities or without the necessary lack of experience or knowledge unless they are supervised by a person who is responsible for their safety or were instructed by that person in how to use the device.  Children should be supervised to ensure that they donot play with the device. Always keep children and unauthorized persons out of reach of the appliance.Operation is only allowed with a safety switch against stray current (RCD max. stray current of 30mA). Please ask your electrician. Before putting into operation, a qualified electricianmust check whether the electric safety measures required are in place.Any national regulations in this regard must be complied with. Electric connection to a socket. Do not expose the appliance to rain and do not use it in wet or moisture conditions. It is necessary to make sure the connecting socket
was not near water and humidity and the plug was  protected against humidity. Avoid installing the appliance in wet shafts (risk of short circuit, corrosion effects)! Check the voltage. Technical data given on the type label must correspond with the electric network voltage. Only use splash proof extension cables approved for outdoor purposes. Do not grab the feeder cable, plunge the pump, lift or carry it while it is connected to the grid! Check the cable and/or socket for damages before the appliance putting into operation. To avoid danger, a damaged mains supply pipe must be replaced by the manufacturer. Do not under any circumstances attempt any repair yourself. Protect the feeder cable from excessive temperatures, oil and sharp edges. If the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.). The pump must not in any case run without fillings. Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it. The temperature of the drained liquid must not exceed +35 °C. When using the pump for domestic water supply, always observe the local regulations of water management authorities and the waste water drainage. If the pump is used in ponds, wells, etc. and appropriate pumping stations, standards valid for pumps in the given country must unconditionally be observed. Do not use pump at outside temperatures over 40 °C or under 0 °C In cold weather, the pumping body motor should not be wrapped in a blanket or another piece of textile with intent to prevent the water freezing. The user is responsible to third parties if pump (dumping stations, etc.) is used.
Requirements for operating staff
The operating staff must carefully read the Operating Instructions before using the appliance.

  • Qualification: Apart from the detailed instructions by a professional, no special qualification is necessary for appliance using.
  • Minimum age: Persons over 16 years of age can only work on the appliance. An exception includes youngsters trained in order to reach knowledge under supervision of the trainer during occupational education.
  • Training: Using the appliance only requires corresponding training by a professional or the Operating Instructions. No special training is necessary.

Emergency procedure

Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. For the sake of eventual accident, in accordance with DIN 13164, a workplace has to be fitted with a first-aid kit. It is essential to replace any used material in the first-aid kit immediately after it has been used. If you seek help, state the following pieces of information:

  1. Accident site
  2. Accident type
  3. Number of injured persons
  4. Injury type(s)

Symbols

Gude-GP-6035-Water-Pump-FIG-1 \(10\)

  • Read the Operating Instructions

  • Before carrying out any work on the machine, disconnect the plug from the socket.

  • Cable pulling/transport prohibited

  • Not frost-resistant

  • The temperature of the drained liquid must not exceed +35 °C.

  • Caution! Not too strong and not tighten with pliers.

  • Staying in the transportation medium prohibited

  • Warning against dangerous electric voltage

  • Warning against automatic starting

  • Accessories – not included in the supply; recommended equipment specified in the list of accessories

  • Any damaged or disposed electric or electronic devices must be delivered to appropriate collection centers.

  • Protect against humidity

  • This side up

Maintenance

Before carrying out any work on the machine, disconnect the plug from the socket. Prior to every use, visually check the machine to rule out any defects, in particular on the power cable and the plug. The machine must not be used under any circumstances if the machine or the safety devices are damaged. In case of a failure of the pump, a repair can only be executed by the GÜDE service center. Original spare parts are to be used only. Caution: Standing water may corrode (brownish color) in the pump according to design. During winter storing, it is necessary to make sure there is no water in the appliance as the frost could damage the appliance. Prior to transportation, it is necessary to unplug the pump from the grid! The device has to be completely emptied and stored with frost-proof protection. Adhesion of mechanical seals can be prevented if you rinse the pump with the appropriate oil (for example, vegetable oil). Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can lead to unforeseen accidents and injuries.

Guarantee

The warranty period of 12 months applies to commercial use and 24 months applies to private use and commences on the day of purchase of the device. The guarantee solely covers inadequacies caused by material defects or manufacturing defect. An original payment voucher with the date of the sale needs to be submitted for any claim in the guarantee period. The guarantee does not cover any unauthorized use such as appliance overloading, use of violence, or damage as a result of any unauthorized interference caused by foreign items. Failing to follow the operating and assembly instructions and common wear are also not included in the guarantee. GÜDE cannot be held responsible for damages incurred in a consequence of unqualified installation or unskilled handling of the pump. The device has to be checked on a regular basis to ensure perfect functioning. Let us refer to the fact we do not assume any responsibility – according to standards in force – for damage eventually caused by our appliances in the below mentioned cases:• Unprofessional repairs executed by unauthorized service centers;• Use in conflict with the designed purpose, or failure to observe the use as designed;• Pump overload with a continuous run;• Damage as a result of icing or any other fault caused by climatic influences; Identical regulations apply for accessory parts. To prevent damage (such as flooded rooms, etc.) as a result of faulty pump operation (failure or fault) the owner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).

Disposal
The disposal instructions are based on the icons placed on the appliance or on the package. Description of the respective meanings can be found in the section „Marking“. Any damaged or disposed devices must be delivered to appropriate collection centres.
Transport packaging disposal
The packaging protects the machine against damage during transport. Packaging materials are usually chosen based on environment aspects and waste treatment principles and are therefore recyclable. Returning the packaging into material circulation saves raw materials and reduces waste production. Parts of packagings (e.g. foils, styropor®) can be dangerous for children.
Risk of suffocation! Keep parts of the packaging out of reach of children and dispose them as soon as possible.

Service

  • Do you have any technical questions?
  • Any claim?
  • Do you need any spare parts or operating instructions?

We will quickly help you and without needles bureaucracy at our web pages at www.guede.com. in the Servicing part. Please help us be able to help you. In order to identify your device in case of claim we need the serial No., product No. and year of production. Allthis data can be found on the type label. Please enter it here for future reference

  • Serial No.:
  • Art. No:
  • Year of production:

Important information for the customer

Please be sure to know that returning the product in or after the warranty period must be made in the original packaging.

Inspection and maintenance plan

Time interval Description Any other details
As needed Clean the check valve and the prefilter. Check the check valve

function.

Failures – causes – removal

Failures Causes Removal
Engine does not start No power supply. Blocked pump wheel Turn the engine

shaft with screwdriver through the fan cover (to release

friction circles sealing that may be stuck

together).

Pump does not suck| Missing, loose or blocked check valve Check valve is not in water.

No water in the pump shell. Too high suction head.

Air bubbles in the suction pipeline. Connections not sealed, pump sucks air, pump is not deaerated.

| Fix or clean the check valve. Immerse the check valve into water. Fill the pump shell with water.

Check the suction head.

Check the tighten of the suction pipeline. Carefully repeat the connection according to the chapter „Connection“!

Thermal detector switching the pump off

4

| Pump is overheated and switched off by the thermal overloading protection.

No electric power supply.

Impurity particles (e.g. pebbles) have settled down in the suction hole.

| Let the device get cool!

Check the voltage

Wasser| Too high suction head. The water level drops quickly.| Check the suction head.

Clean the pump and replace worn parts. (qualified workshop)

Translation of the EC-Declaration of Conformity
We, hereby declare the conception and construction of the below-mentioned appliances correspond – at the type of construction being launched – to the appropriate basic safety and hygienic requirements of  EC Directives.In case of any change to the appliance not discussed with us the Declaration expires.

CONTACT

  • GÜDE GmbH & Co. KG
  • Birkichstrasse 6
  • 74549 Wolpertshausen
  • Deutschland
  • Tel.: +49-(0)7904/700-0
  • Fax.: +49-(0)7904/700-250
  • eMail: info@guede.com.
  • www.guede.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals