EATON MTL Surge Protection Installation Guide
- June 12, 2024
- EATON
Table of Contents
- INTRODUCTION AND SCOPE
- WHAT IS SURGE PROTECTION?
- RISK FACTORS
- ECONOMIC FACTORS
- HOW SURGES THREATEN A NETWORK
- HOW SURGE PROTECTION DEVICES WORK
- APPLYING SURGE PROTECTION TO A LOCAL AREA NETWORK
- SELECTING LAN SURGE PROTECTION HARDWARE
- Appendix 1: Surge voltage along a conductor
- Appendix 2: Surge protection devices and LAN cable testers
- Appendix 3: Structured cabling and surge protection devices
- Appendix 4: Case Study – Damage to a 10Base-5 LAN
- Appendix 5: Product selection guide
- Appendix 6: surge protection checklist
- Appendix 7: questions and answers
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MTL Surge Protection
Installation Guide
SURGE PROTECTION FOR LOCAL AREA NETWORKS
INTRODUCTION AND SCOPE
The purpose of this Guide is to describe the application of surge protection to local area networks (LANs), and to assist the reader in answering the following questions:
- What is surge protection?
- Is my network at risk — do I need surge protection?
- What are the costs and benefits of surge protection?
- Assuming I were to invest in surge protection, how would I apply it to my network?
- How do I choose surge protection products?
This Guide does not attempt to be a treatise on networks, the subject being so
vast, and some knowledge of networks and basic electrical theory is assumed.
For those new to the subject, the further reading section contains some
helpful references. Similarly, some of the surge protection topics covered are
dealt with more fully in the other Eaton’s publications listed.
The reader primarily interested in networks and coming new to surge protection
may well discover that there is a need for surge protection at his site which
extends beyond network protection. An example might be fax machine and modem
connection to copper telephone cables. Should this be the case, Appendix 6
provides some guidance, Eaton’s staff will be pleased to assist further.
WHAT IS SURGE PROTECTION?
Electronic systems can be damaged or disrupted by what we refer to here as
“surges”. These are voltages which are much greater than the normal working
voltage and which appear in a system such as a local area network for a short
period of time, and hence are also sometimes referred to less succinctly as
“transient over-voltages”.
These surges can arise from switching of nearby heavy electrical equipment or
from the clearance of an electrical short circuit fault (e.g. by a fuse
blowing), but the most potent source is lightning. We shall be covering this
in more detail, but it is important to appreciate that although catastrophic
damage can indeed result from a direct lightning strike to one’s building,
this is relatively rare. Far commoner is the substantial damage to electronic
components inflicted by a strike to ground within a distance of the order of a
kilometer or so. As we shall see, this can produce a surge on cables feeding
vulnerable electronic equipment, resulting in damage. Typical damage to a
circuit board consists of such items as scorched and vaporized copper track,
burned and open-circuit resistors, integrated circuits with part of their
package blown away, and semiconductor junctions failed short-circuit.
At a lower level, but more insidious, is latent damage to semiconductors which
subsequently fail perhaps months later, as can happen with electrostatic
discharges.
Surge protection consists of the use of hardware devices, increasingly termed
surge protection devices (SPDs, see glossary for other terms), which, cor-
rectly positioned and installed, limit surge voltages reaching protected
equipment to a safe level. The operation of SPDs is covered briefly later for
the interested reader.
2.1 How big are surges?
We can characterize lightning-induced surges by:
a) Open-circuit voltage: the peak voltage which would be measured on a cable
assuming no breakdown occurred
b) Short-circuit current: the peak current flowing once breakdown has
occurred, as commonly happens.
c) Time: the time taken for the voltage or current pulse to rise to the peak
and then decay. Lightning impulses have a fast rising edge, occupying a few
microseconds, and a relatively slow decay of tens to hundreds of microseconds.
Experience of surge damage and the successful operation of surge protection
devices indicates that one needs to be prepared to contend with voltages of
the order of kilovolts to tens of kilovolts, and currents of kiloamps to low
tens of kiloamps.
2.2 Surge protection and network layers
Fully defining a network is a huge undertaking. For those familiar with the
Open System Interconnection (OSI) seven layer reference model employed for the
task, and shown in figure 1, it is worth making the point that surge
protection is concerned exclusively with the physical layer. This means that
considerations for SPDs are with such things as signal voltages, impedances,
losses and bandwidth, and with connectors and cable types.
SPDs are applied to network and other signal cables including telephone lines
and the mains power supply.
Having discussed briefly what surge protection is, the next two sections
outline some of the factors to be taken into account by the reader when
considering investment in surge protection. The decision, which will
inevitably be partly subjective, will be based on an assessment of the
probability of damage, for which impartial assistance can be obtained, and the
consequences of that damage, which the reader must assess for himself.
To give examples in a wider context, at one extreme might be a petrochemical
plant in a lightning-prone area, handling potentially flammable and explosive
liquids and gases. The loss of telemetry or control could have disastrous
consequences. At the other extreme, a damaged TV set in an area of low
lightning incidence may involve no more than a once-in-a-lifetime insurance
claim and the purchase of a new TV!
RISK FACTORS
As with insurance, the only certainty with surge protection is the cost of
obtaining it! The risks must be described in terms of probability only. It is
entirely possible that in a given location, damage due to lightning may not
occur for twenty years, and then twice in the same week.
A risk analysis can be undertaken using British Standard BS 6651: 1999,
Appendix C, General advice on protection of electronic equipment within or on
structures, against lightning, which is the best reference of which we are
aware. This publication identifies risk factors which affect the probability
of equipment suffering damage.
- Frequency of lightning strikes to ground. u Size and exposure of building.
- Soil resistivity (the higher the resistivity, the greater the risk).
- Number and length of copper cables entering a building. These include mains power, telephone and data cables.
- Vulnerability of equipment. Sample calculations are given in the standard.
ECONOMIC FACTORS
Even after deciding that the risk of damage might be great enough to warrant
surge protection, there is still the hurdle of cost to be considered. The cost
of a good SPD is of the order of tens of pounds (£), and installation work in
addition may well cost much more. The cost of computing and networking
hardware has fallen dramatically over recent years. The cost of providing
surge protection may appear prohibitive, particularly for small networks with
a few computers, relative to, say, replacing a damaged network card or PC.
However, the following need to be borne in mind:
-
Many businesses and organizations are now very reliant on their network. If the network is out of action, the business is paralyzed.
What is the cost to you of this “down-time”? -
Restoring the network may not simply be a matter of quickly replacing an item of hardware because:
• There may not be anyone with the required skills and confidence on site.
• Identifying a single faulty item of hardware is not always straightforward.
• There may be damage to more than one item, which will add to the difficulty of fault-finding.
• Replacement hardware may not be readily available. Hardware, even though it may be performing an invaluable job for your business, becomes obsolete and hard to replace, remarkably quickly. -
Can lost data be guaranteed to be retrieved?
Some insurance companies are now advising surge protection, and it is quite
possible that this will become a factor in premiums and the willingness to
cover a claim in the event of damage.
In summary, hardware can be insured and replaced easily and quickly. Data may
be priceless, loss of data more than an inconvenience.
The next two sections are intended to give an insight into how surges
infiltrate networks, and very briefly, how surge protection devices work. The
reader lacking time or interest in these topics may wish to skip to the
section on applying surge protection.
HOW SURGES THREATEN A NETWORK
In this section we deal with:
- Ground potential surge due to a nearby lightning strike to ground probably the greatest threat of damage to the largest number of networks.
- Direct strike to a building housing a LAN, a severe threat to a relatively few.
- Mains power supply transients due to lightning strikes to power lines, supply switching and faults, a moderate threat to an intermediate number of LANs.
Ground potential surge due to a nearby lightning strike to ground:
A lightning strike to ground consists of a number of strokes of differing
intensity. Currents of typically tens of kiloamps (1 kiloamp = 1000 amp) flow
through surface layers of e.g. soil, clay and rock in the process of
discharging the electrostatic energy of the thundercloud. Figures of 100kA and
200kA are used to illustrate worst-case direct strikes.
Because the ground is an imperfect electrical conductor, these lightning
currents can develop extremely large voltages (or “potentials”) between points
on the earth’s surface. For instance, 100kA flowing through 10 ohm, not a
particularly high value of ground resistance, develops 1 million volts (1
megavolt!) across metres or tens of metres of ground. This is the ground
potential surge.
Two buildings in the vicinity of a nearby ground strike but separated by some
distance, will experience different potential shifts, and their electrical
earths, which are connected to their local ground via earth systems such as
rods and mats, will briefly have a large potential difference between them. If
the buildings’ electrical systems are contained entirely within their
structure, this does not present a problem. If, however, a cable such as a LAN
cable links the buildings, equipment in one will be subjected to the relative
ground potential of the other, which may well be sufficient (kilovolts or
greater) to cause damage when current (tens to thousands of amps) flows as a
result of destructive breakdown within the LAN equipment. Figure 2 illustrates
this. The surge voltage depends on the location of the lightning strike, its
current, the ground resistivity, and the distance between the buildings.
It would be prudent to fit surge protection devices (SPDs) when cables longer
than a few metres, link buildings. In effect, the external cable presents a
large “capture area” for transients.
Although the focus of this Guide is on LANs, the wider context must not be
neglected. The typical modern building is served by a number of cables
carrying signals from points not tied to the building’s electrical earth.
These can include telephone lines, now commonly feeding fax machines and
modems, antennas, video security camera links and external lighting cables.
Each one carries the threat of damage from the ground potential surge, and
surge protection should be considered for each (see the checklist in appendix
6).
Direct strike to a building
We have tended to play down the risk of direct strikes, because they affect
relatively few people. Nevertheless, for tall buildings such as corporate
offices exposed to lightning activity, the threat of direct strikes is very
real, and the assumption must be made that it will happen. We consider here
how a LAN in such a building can suffer damage.
In the event of a direct lightning strike, the full strike current flows through the building’s lightning conductor system.
Figure 3 shows how side-flash can arise. Lightning strikes an air termination
and travels down a conductor on the surface of the building. The voltage
across a length of cable due to a rapidly changing current flowing through it
depends on the rate of change of current and the cable’s self-inductance. The
calculation given in Appendix1, based on BS 6651 information, shows that a
voltage of 1.5 million volts (also written megavolts or MV) can be developed
along a 30 metre lightning conductor.
If cables which are at the potential of the surrounding earth are run close to
walls which are not metal clad, there may be side-flash. This is rather
extreme and the ensuing current may cause severe damage. Modern building
construction techniques with all structural metalwork bonded and earthed,
should make this relatively rare.
A less extreme case involves voltages induced by capacitive or inductive
coupling (see figure 4). Capacitively-induced voltages will be greatly reduced
if the cables are run in earthed metal ducting.
It is not easy to provide definitive information on the voltages expected
within buildings struck by lightning. BS 6651 appendix C, figure C4 gives a
figure of 1500V induced in a 2 metre high wiring loop when a direct strike
current flows down a building’s lightning conductor system, assuming a peak
rate of current rise of 50kA/µsec. One difficulty in providing definitive
figures is that although the purpose of the lightning conductor system is to
provide, in effect, a screened enclosure for the building, in reality, this
will be an approximation, and depends on the construction used. A metal-
skinned building, with all parts bonded, can be very good. Those with large
areas of glass may be another matter.
A calculation presented at the ERA Seminar on Lightning Protection (see ERA
Report no. 87-0328) was that of the voltage across the ends of a large loop
within a building, 1 metre from a current-carrying lightning conductor.
The wiring loop could be a combination of mains power & network cabling, via
computers. Note the modest figure of 2kA/µsec for the rate of rise of current.
5.1 Reducing the risks
From BS 6651, Appendix C, “General advice on protection of electronic
equipment within or on structures against lightning”: To reduce the risk of
damage to equipment within conventional modern metal framed buildings, section
C.7.2.1 advises locating electronic equipment towards the centre of the build-
ing and avoiding the top floor, near air terminations. If possible, data and
power lines should be run in adjacent ducts to minimise loop areas (figure C9
of the standard).
This section of necessity appears somewhat theoretical. It is difficult to
assess how much damage of this sort is actually happening. A network being out
of action is not something which companies are likely to publicize, and as
noted earlier, some damage may be latent, occur later, and therefore not be
associated with lightning. Anecdotally, the Financial Times once reported: “….
Amstrad’s design department found its machines reset when a horizontal bolt of
lightning zipped past its windows…”, though no damage was mentioned.
Mains power supply transients due to lightning strikes to power lines, supply
switching and faults
We have concentrated primarily on surges which enter equipment via the LAN
signal cables. However, the mains power supply presents another route. As
shown in figure 6, a direct strike to a high voltage power line can, via
capacitive coupling through transformers produce a mains power supply surge.
Even though greatly attenuated from the original, this can be great enough to
cause equipment damage.
Not all surges are caused by lightning. Some originate inside a building’s
electrical system as a result of the interruption of a large supply current.
This could result from the switching of loads such as lifts and motors, or
from
fault currents, this being illustrated in figure 7 below. A fault develops
which short-circuits the supply. When the short-circuit current is suddenly
interrupted by the opening of a fuse or circuit-breaker, an inductive
transient voltage is produced. The waveform will typically be a damped
oscillation, the peak voltage being related to the rate of change of current
and the inductance of the supply cable.
HOW SURGE PROTECTION DEVICES WORK
An SPD can helpfully be thought of as a switch which is normally open, but
which closes when the voltage across it exceeds a threshold level. It is not
intended to go into internal details here, merely to note that SPDs use
components such as gas discharge tubes, diodes, resistors, inductors and metal
oxide varistors.
A typical SPD for use in protecting data cables will limit the voltage between
the conductors of the data cable (“difference mode”) and between the
conductors and earth (“common mode”). Common mode surges are more potent in
terms of voltage and current, and are more difficult to deal with, since a low
impedance earth connection is required. An SPD can only do its job if
correctly installed, and this is the main theme of reference P2 (see Further
reading). Figures 8 & 9, taken from this ‘Earthing guide…’, illustrate SPD
operation.
In acting as a switch, the SPD conducts very large transient currents with an
output voltage low enough to avoid damage to the protected equipment. All the
current flows through the SPD and none through the equipment.
The reader may at this point be wondering
whether, given the need for an earth connection and a large, if brief, current
flow, it would be a better idea to use a series protection device which goes
open circuit during a surge. The “series isolation” protection can be effected
by unplugging connectors (thereby losing the signal) before or during a storm,
or more elegantly, by using optical fibres. However, surge voltages can be so
huge a series device is simply not practical on a “copper” data cable. BS 6651
appendix C (see Further Reading) states that “high impedance isolation devices
are not satisfactory on their own unless they have a withstand voltage greater
than 100kV owing to the large potential difference occurring between
unprotected buildings resulting from lightning current flow into the ground
from one of them.”
Note that for effective protection, mains power SPDs are needed in conjunction
with network and other signal protectors, and are generally earthed via the
electricity supply earth.
An SPD for use on a LAN, will have had the following factors taken into account:
- Cable and connector type
- Signal levels
- System impedance (e.g. 50 ohm for coaxial Ethernet™)
- Allowable attenuation and/or series resistance
- Bandwidth required, based on signaling speed
- Surge current handling
- System earthing arrangement
- Physical size constraints
- Method of installation
This accounts for the variety of products available.
It may appear that the maximum surge voltage which the LAN can withstand has
been omitted. In practice, this is not always known and will vary as new
equipment is added to the LAN, and in any case, the SPD is usually designed
for the lowest possible limiting voltage, allowing a margin above the normal
signal level, as illustrated by figure 10.
APPLYING SURGE PROTECTION TO A LOCAL AREA NETWORK
Surge protection devices can only be effective if properly installed, and this
section provides some basic guidelines. For the sake of brevity, it is
somewhat prescriptive and Earthing guide…. TAN1003 should be studied if an
understanding of the reasoning is required. Some readers may be somewhat
disheartened to find that practical considerations such as the routeing of
network cables mean that not all the guidelines can be followed. These
concerns are at least partly addressed, and provided that limitations are
recognised, a good level of protection for at least part of the system can be
achieved – much better than doing nothing!
First, the guidelines for the case of a network where the LAN cables run
between buildings which either have structural lightning protection fitted, or
for which the risk of a direct strike is negligible:
- LAN cable routing: run the cables which pass between buildings close to the mains power distribution boards, from which the electrical supply earth for each building is derived.
- Fit a network SPD in the LAN cable close to the mains power distribution board in each building. Each building should be treated alike, since the concern is with potential differences between the two building earths.
- Earth the SPD at the mains power distribution board with the shortest possible length of cable with a minimum cross section of 2.5mm2. Better still, use several cables electrically in parallel, spaced apart from each other. Best of all, fit the SPD on earthed metal panels if available.
Apart from a direct strike to the building, the result will be protection for
the entire LAN cable in the building, using only one LAN SPD per building.
Suppose that the LAN cable cannot practically or economically be routed as
described above? In this case, it is not possible to position a single LAN
plus mains power SPD so as to protect the entire network with as great a
confidence. Individual items of hardware can be fully protected, however, with
lesser protection offered to the rest. While not wishing to dissuade from
fitting SPDs to each item on the network (!), in practice it would be sensible
to decide on the most strategically important, such as the file and
application servers, and fit SPDs there. Figure 11 shows how this should be
done, using short connections to the equipment earth point. (The need for a
mains power as well as a LAN SPD is explained in TAN1003, section 7.4.)
The reason why this does not offer complete protection is shown in figure 12
below. When the LAN cable is subject to a surge, i.e. at a high voltage
relative the building’s electrical supply earth, the SPDs operate and protect
the equipment to which they are attached. However, depending on the layout of
the wiring, the current pulse generates an inductive transient voltage which
may be enough to break down insulation in other devices and cause damage. The
energy in this transient depends on the inductance and the peak current. As
this will be much
lower than the energy in the original transient, the network will still have
benefitted greatly from the fitting of even partial protection.
We dealt earlier with the less well-defined threats to LANs in a single
building. The advice in this situation is similar to the case of external
cables which are non-ideally routed covered in the paragraphs immediately
above. Identify the most strategically important items of equipment and fit
protection locally to these.
SELECTING LAN SURGE PROTECTION HARDWARE
This section is intended to assist in choosing the appropriate network
protection devices available from Eaton’s MTL product line. It is intended
merely as a pointer, and the product literature should be consulted for full
details. No comparisons are drawn with other manufacturers’ offerings.
However, the reader should be aware that the devices offered by Eaton and
other reputable companies, are designed to protect and survive repeated large
surges. Lowcost LAN protection products are on the market which, while
probably offering protection, are sacrificial and do not survive a significant
surge. These are likely to give a false economy since their failure will stop
the network functioning and this will absorb time and effort in fault-finding
and re-ordering.
The main LAN types are briefly covered, with the SPDs suitable for the
application. There is then a tabular summary covering a greater range of named
networks. Yet again, the point needs to be stressed that full protection often
requires additional SPDs on the mains power supply and, for instance, on
telephone cables.
- Newer, faster LANs:
Some computer applications, such as real-time video, require very large amounts of data to be transported around a network. This is especially so when images are involved. The volume of traffic can slow the network down.
|
---|---
A lot of work has therefore been put into increasing the capacity of networks.
One way of doing this is to use faster data rates. Fast (100Mbps or more)
systems are now being installed which have a data rate along the cables ten
times that of standard Ethernet. Some years ago, FDDI (Fibre Distributed Data
Interface) using optical fibre and allowing up to 1km links, was promoted as
the answer and predicted to overwhelm other systems, but cost of hardware and
installation (requiring precision work with connectors) has prevented this.
New systems using copper cable have been developed.
As usual, there is more than one competing system, the main contenders being
Asynchronous Transfer Mode (ATM), versions of 100Mbps Ethernet such as
100Base-T, 100Base-T4 and 100VG-AnyLAN, and CDDI (C = Copper) i.e. FDDI using
copper cables.
The defining standard for this too is ISO/IEC 8802-3, ANSI/IEEE 802.3 (S3,
further reading)
Details of some articles on these and the related topic of structured cabling
are given in the Further Reading section.
The Atlantic Scientific Zone Barrier ZBS 24550 (with ASC 24500 rack mounting
kit) and Telematic NET 905 are available for use on unshielded twisted pair
cables carrying data at up to and beyond 100 Mbps. Protection is provided for
all four pairs of standard cable, including category 5. The NET 905 is a
single unit, protecting one cable, while ZBS 24550 is a 32-way rack-mountable
unit protecting up to 64 cables.
A further product selection guide is given in appendix 5.
-
Twisted pair Ethernet 10Base-T (ISO/IEC 8802-3):
• Data rate 10 Mbps
• Cable type: unshielded twisted pair (UTP) or shielded twisted pair (STP). Two pairs are required, though the actual cable used commonly contains four pairs.
• Cable characteristic impedance 100 ohm.
• Connector type: RJ45.
The cabling used is relatively inexpensive and flexible. If a computer in an office is moved, it can be re-connected to the network on a new length of cable plugged into the hub without disrupting other users. With coaxial Ethernet systems, the cable has to be routed close to all workstations, and for instance, re-arranging an office, a popular modern pastime, could involve expensive recabling. Also, if the coaxial trunk cable is broken, the entire network, or network segment if repeaters are used, ceases to function.
The Atlantic Scientific Zone Barrier 24540 or Interface Protector IP 70015 (which incorporates an RJ45 connection system) can be used to protect Token Ring networks. An alternative to the RJ45 connection system is an IP 70014 which employs a DB9 connection. IP Series devices provide in-line I/O port protection for RS232, RS423, 10Base-T and Token Ring, on DB9, DB15 and DB25 style connectors.
Products available from Eaton’s MTL product line:
• Telematic NET 905 (4-pair protection, RJ 45 connectors, freestanding)
• Atlantic Scientific Zone Barrier ZBS 24550 (Protection for sixteen, 4-wire cables, RJ45 connectors, in ASC 24500 rack mounting kit) -
IBM Token Ring (ISO/IEC 8802-5):
• Data rate 4 or 16 Mbps.
• ISO/IEC 8802-5 (ANSI/IEEE 802.5) standard specifies this type of token passing network.
Originally, a number of types of shielded twisted pair (STP) cables were specified, known as IBM type 1,2,6 or 9, with a 150 ohm characteristic impedance, produced in indoor and outdoor versions, and special connectors. More recently, unshielded twisted pair (UTP) 100 ohm cables have been adopted, using RJ45 connectors. Maximum cable length in the ring, depending on type, is 366 metres. -
Thin Ethernet (10Base-5) summary:
• Coaxial cable characteristic impedance: 50 ohm.
• Typical coaxial cable: RG58
• Bit rate 10 megabits per second (10 Mbps)
• Connector type: BNC
• Maximum cable length per segment: 185 metres
• Repeaters allow cable segments to be added to extend the total length of the network
• Defining standards: ISO/IEC 8802-3, ANSI/IEEE 802.3 (S3, Further Reading)
• Appropriate Telematic SPDs: ZoneBarrier ZBS 24534
The Telematic building in Luton has a thin Ethernet network with one repeater, since more than 185 metres of cable is used.
Appendix 1: Surge voltage along a conductor
When a current flows in a conductor, a magnetic field appears around the
conductor. If the current changes, the changing magnetic field is said to
“induce” a voltage which appears along the length of the conductor. The
polarity of the voltage is such as to oppose further change in the current.
This property of a conductor of resisting the flow of a changing current is
known properly as the “self-inductance”, but more commonly as simply the
“inductance”. It is measured in units of henries and for conductors of about
2mm diameter with say a length of up to 100m would have a typical self-
inductance value of 1µH/m (1microHenry per metre).
The voltage produced across an inductance is given by: where V is the voltage,
L is the self-inductance and the rate of change of current. The minus sign
indicates that the voltage opposes the rate of change of current. It is
commonly omitted when only the magnitude of the voltage is required.
Taking L = 50mH (for 50 metres of conductor on a moderately tall building,
assuming 1µH per metre) and = 30kA/µsec, a value for lightning stroke current
quoted in BS 6651 appendix C, we get a voltage of 1.5MV (1.5 megavolts).
Note that the inductance value is a “rule of thumb” figure. As conductor
length increases, the inductance increases somewhat faster than
proportionally, so the voltage calculated above is an underestimate.
Appendix 2: Surge protection devices and LAN cable testers
When the installation of network cabling is complete, it is quite common for
the installer to check the integrity of the cables sections and connectors
using a cable tester. Some of these use a technique known as time domain
reflectometry (TDR). In this, a pulse is sent down the cable, and the strength
and delay of the return or echo signal is measured in a manner somewhat
analogous to radar. A well-terminated cable in good condition should give a
weak return signal, and therefore a high so-called “return loss”.
The pulses used have very fast edges to allow accurate timing of the return
signal, and very large bandwidths, of the order of several hundred megahertz
(MHz) are needed to transmit the pulses without distortion, a condition met by
good network cables.
However, an SPD with its protection components has a more limited bandwidth
and appears to the cable tester using TDR as a low-pass filter, presenting a
significant return signal that is, a low (poor) return loss, even though no
fault exists.
For this reason, LAN cable testing using the TDR method should be carried out
without any SPDs installed in the cabling.
Appendix 3: Structured cabling and surge protection devices
Traditionally, wiring within buildings has ended up as a mess, with telephone
and computer network cables trailing all over the place. Structured cabling
(or “wiring”) is an attempt at an orderly solution, by wiring a building with
an infrastructure of twisted pair cable and wall outlets (or “wall ports”).
The signals conveyed by the cabling can be voice or data, depending on the
user’s needs. If these needs change, there is no need to re-cable, which can
be extremely expensive.
Cables and connection systems have been characterised according to their
performance with frequency, the most demanding category currently installed
being “category 5”, which is specified up to 100MHz, a frequency most people
would once have considered far too high to be transmitted along twisted pair
cable looking superficially much like telephone cable.
In summary, the idea of structured cabling is to provide a flexible cable
infrastructure through which a wide variety of signals can be passed. However,
surge protection devices, are designed to protect specific types of equipment
and should not be regarded as part of this infrastructure. For example, an SPD
for analogue telephone signals will have a limiting voltage of the order of
200 volts to accommodate battery and ringing voltages, whereas an SPD for a
LAN application will be designed with a limiting voltage of a few volts to
give optimum protection.
Appendix 4: Case Study – Damage to a 10Base-5 LAN
Two 10Base-5 (Thick Ethernet) LANs, joined by a bridge, serve two factory
buildings and an office, with the network cables linking the buildings as
shown in figure below. Several transceivers (at positions A) have suffered
damage.
Why the particular transceivers have suffered damage is a matter of
conjecture. It may be that some are more robust than others, and that in
failing, the damaged units saved the others.
The mains power supply is distributed from one point in each office and fac-
tory. We are not told whether the network cables pass close to the mains
distribution board. The protection we apply depends on whether the network
cables:
- Run close to the distribution board, or can be re-routed to do so, or;
- Are distant from this point.
In case (1) network surge protection devices (SPDs) type ZoneBarrier ZBS 24534
should be installed at positions B in figure A4.2, close to the mains power
distribution board, and earthed there using as short a length of cable as
possible, with a diameter of 2.5mm2 or greater (length is much more important
than diameter). To reduce the effect of cable inductance, several cables can
be run electrically in parallel, but spaced apart physically. If earthed metal
panels are available at the distribution board, these would offer further
reduction in inductance, and better protection.
Mains power protection should also be considered, the minimum requirement
being for a heavy duty protector located at the distribution board.
In case (2), it is not possible using as few SPDs to give full protection to
the LANs. The decision must be made as to which network transceivers to
protect. A ZoneBarrier ZBS 24534 should be installed close to each PC to be
protected, and earthed at the same point as the PC, for instance at the supply
socket into which the PC mains power cable is plugged. Again, the minimum
length of earth cable must be used.
Appendix 5: Product selection guide
As the following guide shows, there is a large number of network types in existence. The table gives product suggestions for a number of these. Those in italics indicate products thought to be suitable for these LAN types less commonly encountered.
LAN | Product(s) |
---|---|
Thin Ethernet (10Base-2, IEC8802.3) | ZB24534 |
Twisted pair Ethernet (10Base-T, IEC8802.3) | ZB24534, NET 905/ZB24550 + |
ZB24500
Fast (100Mbps) Ethernet (100Base-T)| ZB24534, NET 905/ZB24550 + ZB24500
100VG-Anylan| ZB24534, NET 905/ZB24550 + ZB24500
Token Ring (IEC8802.5)| ZB24540
ATM (Asynchronous Transfer Mode)| ZB24534, NET 905/ZB24550 + ZB24500
Star LAN 1Mbps (1Base-5, IEC8802.3)| ZB24534, NET 905,/ZB24550 + ZB24500
Arcnet| ZB24537
Apple EtherTalk| ZB24534
Novell E-Net| ZB24534
Novell G-Net| ZB24534
Wangnet (Wang Laboratories)| ZB24534
Broadband Ethernet| ZB24540
New LAN surge protection applications
We will be pleased to discuss other LAN applications. As noted earlier,
although a vast amount of information is involved in defining a network, surge
protection is concerned only with the physical layer. Selecting or designing a
surge protection device requires the following information:
- Cable and connector type
- Signal levels
- System impedance (e.g. 50 ohm for coaxial Ethernet)
- Allowable attenuation and/or series resistance
- Date rate or bandwidth required – the SPD must have sufficient bandwidth to pass the wanted signals without undue loss or distortion.
- System earthing arrangement
- Physical size constraints
- Method of installation
Much of this information can usually be gleaned from published standards.
We also take a judgement on the likely exposure to surges.
Appendix 6: surge protection checklist
Whether to protect
The following factors would tend to flavour fitting surge protection:
- Surge damage has been suffered, or is suspected.
- Surge damage has been suffered by other nearby organizations.
- A risk analysis has been carried out indicating a significant risk of damage.
- The consequences of surge damage are serious, despite a low probability.
- Surge protection is specified or recommended by an insurance company or parent organisation.
- Good experience of surge protection in a related field.
What to protect
Assuming that some form of surge protection is decided upon, it is important
to take a broad view of the whole electrical installation, and at least
consider fitting surge protection devices to the following cables, each of
which, if present, can provide a means of coupling lightning-induced surges
into the installation:
- Mains power electricity supply
- Telephone lines feeding fax machines & modems
- Data cables for local area networks
- Cables for telemetry and instrumentation & control
- Antenna cables
- Security camera cables
- Outdoor lighting cables
Note: mains power protection is generally recommended with any of the
others.
Installation of SPDs
a) Cables routed close to the building earth connection at the distribution
board where the mains power electrical supply enters the building:
- Fit SPDs close to this earth connection, mounting on earthed metalwork if available.
- Earth cable from SPD to the supply earth to be as short as possible, cross section 2.5mm2 recommended.
b) Cables routed remote from the building earth connection:
- Decide on which items of equipment are the most important and need fullest protection.
- Fit SPD(s) to the relevant cable(s) close the earth of this equipment. For a PC or fax machine, for instance, this will be the electrical supply earth of the socket into which it is plugged. Any SPD earth cable to be as short as possible, cross section 2.5mm2 recommended.
- Fit a mains power SPD here.
The equipment should then be fully protected, the rest partially protected.
Periodic checks:
- The SPDs themselves should require no maintenance over a life of twenty years or so.
- Periodically check the installation to ensure that the SPD earth connections are intact and sound. An SPD requires a good earth connection in order to do its job.
Troubleshooting – hints for when things go wrong (fortunately rare):
-
SPD installed and network ceases to work. Possibilities are:
• Incorrect product selection.
• Incorrect location, e.g. SPDs installed between trunk cable and PC, rather than in the trunk cable.
• Faulty cables and/or connectors. -
SPDs fitted but surge damage still occurs. SPD may also be damaged:
• A vital cable left unprotected.
• SPD earth cable excessively long.
Note that in general the failure mode for SPDs for data application fail short circuit i.e. they short out the signal, and the data cable remains protected (i.e. they “fail safe”). Such failure can generally be ascertained using a multimeter measuring resistance, preferably with a diode test function. -
Mains power SPD damaged – protection components failed:
• Fault in installation causing prolonged over-voltage (SPDs are only designed to protect against transient over-voltages).
Example: standby generator wrongly connected or with poor regulation.
Appendix 7: questions and answers
Q: My file server is protected by a UPS (Uninterruptible Power Supply). Why do I need a mains power SPD as well?
A: Not all UPSs are protected, or adequately protected, against lightning transients. The heaper the UPS, the less likely it is to contain sufficiently robust protection.
Q: My connection to the outside world is via optical fibre cables. Surely I don’t need any further protection?
A: Optical fibre cables remove the risk from surges that would be associated with a corresponding copper cable, provided that any metallic shield is stripped back at least one metre from where the fibre enters the building. Mains power transients may still be a problem and these can be dealt with by mains power SPDs. If data cabling within the building is copper, and there is a significant risk of direct strike to the building, then protection for this should be considered.
Q: My LAN tester gives a fail message on the TDR (time domain reflectometer) or return loss test when I test the cabling with SPDs installed. Whashould I do - are the SPDs faulty?
A: See appendix : TDR testing of the LAN cabling should be done with the SPDs removed.
Q: I’ve got a LAN and fax machine and modem. Why can’t I use the same type of SPD for all of them?
A: SPDs designed to protect LANs have a low limiting voltage and will, in effect, short out battery and ringing voltages present on analogue telephone lines feeding fax machines and modems.
Q: The shortest earth wire I can use for the SPD is about ten metres. Is this ok?
A: In the event of even a moderate lightning surge, this is almost certainly much too long. We experienced such a case where the inductive transient developed across roughly this length of cable was sufficient to blow apart a ceramic capacitor on the network card, in addition to causing semiconductor damage. The LAN cable should be re-routed to allow an SPD earth of the order of 1 metre or less, or the SPDs should be fitted close to the most strategically important hardware. See section Applying surge protection .......
Q: Won’t a longer earth cable be ok if I use, say 10mm2 cable instead of 2.5mm2?
A: Unfortunately, no. The problem with a long earth cable for surge is almost entirely due to its inductance and not its resistance. Although a 10mm2 cable will have only a quarter of the resistance of a 2.5mm2 cable, the reduction in inductance is minor, and certainly not worth the additional awkwardness of installing it. Length is much more important than cross section.
Q: How many LAN SPDs can I use on my network?
A: Ethernet SPDs such as the ZBS 24534 have less than half ohm series resistance, however normally only 2 units are required (this will not affect the termination resistance of the network). SPDs designed for twisted pair, such as NET 905, do have some small loss and should probably be limited to two per radial cable. This is likely to be the most needed.
Q: I have a 10Base-2 (Thin Ethernet) LAN where the PC workstations are fed from taps on the trunk coaxial cable. Can I install a ZBS 24534 between the cable from the tap and the PCs?
A: No. The ZBS 24534 must be fitted in line with the coaxial trunk cable. The distance between the cable and the PC must be kept as short as possible, as specified in the standards e.g. IEC/ISO 8802.3, otherwise the network may not function.
Glossary The computing and networking field has been a prodigious generator of
terms and acronyms. A very small selection is covered here.
bridge a device for linking two networks
Mbps megabits (millions of bits) per second
PC personal computer
repeater a device for increasing allowable length of cable
SPD surge protection device. Other terms for SPDs can be derived by combining
any one of the words in the left hand column with any one in the right hand
column!
surge
transient
overvoltage
lightning
spike| barrier
protector
protection device
suppressor
arrestor
---|---
Further Reading
Surge protection:
P1) Lightning surge protection for electronic equipment — a practical guide
Application Note TAN1001
P2) Earthing guide for surge protection Application Note TAN1003
Networks & computer communications:
N1) Communications and networking for the PC, Larry Jordan & Bruce Churchill,
New Riders Publishing
N2) Communication Network Protocols, 3rd ed, Brian W Marsden, Chartwell Bratt,
ISBN 0 86238 276 9
N3) ‘100Mbit/sec Ethernet’. An article by Systems Marketing of Compaq Computer
Corporation, 22 May 1995
N4) ‘Is your network cabling infrastructure cut out for fast Ethernet?’,
Personal Computer Magazine, June 1995
N5) ‘Hundreds and Thousands’, Personal Computer Magazine, April 1994.
N6) ‘Categorical Imperatives’, Datacom, July 1994
N7) ‘Cabling strategies for high speed networks’, Telecommunications, January
1993
Standards:
S1) BS ISO 10738: Token ring networks, unshielded twisted pair cable (UTP)
S2) BS ISO 9578: Connectors for communications interfaces
S3) ISO/IEC 8802-3 ANSI/IEEE Std 802.3: Carrier sense multiple access with
collision detection (CSMA/CD) access method and physical layer specifications
Includes 1Base-5, 10Base-2 (“thin Ethernet”), 10Base-5 (“thick Ethernet”) &
10Base-T (“twisted pair Ethernet”)
S4) ISO/IEC 8802-5: Token ring access method and physical layer specifications
S5) ECMA-80: Local area networks CSMA/CD baseband – coaxial cable system
Covers cabling and installation rules for 10 Mbit/sec systems (ECMA = European
Computer Manufacturers’ Association)
S6) ECMA-81: Local area networks CSMA/CD baseband – physical layer
S7) ECMA TR/26: Local area networks CSMA/CD baseband – planning and
installation guide
S8) BS 6651 : 1999 Code of practice for protection of structures against
lightning
AUSTRALIA
MTL Instruments Pty Ltd,
10 Kent Road, Mascot, New South Wales, 2020, Australia
Tel: +61 1300 308 374
Fax: +61 1300 308 463
E-mail: mtlsalesanz@eaton.com|
BeNeLux
MTL Instruments BV
Ambacht 6, 5301 KW Zaltbommel
The Netherlands
Tel: +31 (0)418 570290
Fax: +31 (0)418 541044
E-mail: mtl.benelux@eaton.com| CHINA
Cooper Electric (Shanghai) Co. Ltd
955 Shengli Road, Heqing Industrial Park
Pudong New Area, Shanghai 201201
Tel: +86 21 2899 3817
Fax: +86 21 2899 3992
E-mail: mtl-cn@eaton.com
---|---|---
FRANCE
MTL Instruments sarl,
7 rue des Rosiéristes, 69410 Champagne au Montd’Or
France
Tel: +33 (0)4 37 46 16 53
Fax: +33 (0)4 37 46 17 20
E-mail: mtlfrance@eaton.com| GERMANY
MTL Instruments GmbH,
Heinrich-Hertz-Str. 12, 50170 Kerpen, Germany
Tel: +49 (0)22 73 98 12 – 0
Fax: +49 (0)22 73 98 12 – 2 00
E-mail: csckerpen@eaton.com| INDIA
MTL India,
No.36, Nehru Street, Off Old Mahabalipuram Road
Sholinganallur, Chennai – 600 119, India
Tel: +91 (0) 44 24501660 /24501857
Fax: +91 (0) 44 24501463
E-mail: mtlindiasales@eaton.com
ITALY
MTL Italia srl,
Via San Bovio, 3, 20090 Segrate, Milano, Italy
Tel: +39 02 959501
Fax: +39 02 95950759
E-mail: chmninfo@eaton.com| JAPAN
Cooper Crouse-Hinds Japan KK,
MT Building 3F, 2-7-5 Shiba Daimon, Minato-ku,
Tokyo, Japan 105-0012
Tel: +81 (0)3 6430 3128
Fax: +81 (0)3 6430 3129
E-mail: mtl-jp@eaton.com| NORWAY
Norex AS
Fekjan 7c, Postboks 147,
N-1378 Nesbru, Norway
Tel: +47 66 77 43 80
Fax: +47 66 84 55 33
E-mail: info@norex.no
RUSSIA
Cooper Industries Russia LLC
Elektrozavodskaya Str 33
Building 4
Moscow 107076, Russia
Tel: +7 (495) 981 3770
Fax: +7 (495) 981 3771
E-mail: mtlrussia@eaton.com| SINGAPORE
Cooper Crouse-Hinds Pte Ltd
No 2 Serangoon North Avenue 5, #06-01 Fu Yu Building
Singapore 554911
Tel: +65 6 645 9864 / 5
Fax: +65 6 487 7997
E-mail: sales.mtlsing@eaton.com|
SOUTH KOREA
Cooper Crouse-Hinds Korea
7F. Parkland Building 237-11 Nonhyun-dong Gangnam-gu,
Seoul 135-546, South Korea.
Tel: +82 6380 4805
Fax: +82 6380 4839
E-mail: mtl-korea@eaton.com
UNITED ARAB EMIRATES
Cooper Industries/Eaton Corporation
Office 205/206, 2nd Floor SJ Towers, off. Old Airport Road,
Abu Dhabi, United Arab Emirates
Tel: +971 2 44 66 840
Fax: +971 2 44 66 841
E-mail: mtlgulf@eaton.com| UNITED
KINGDOM
Eaton Electric Ltd,
Great Marlings, Butterfield, Luton
Beds LU2 8DL
Tel: +44 (0)1582 723633
Fax: +44 (0)1582 422283
E-mail: mtlenquiry@eaton.com|
AMERICAS
Cooper Crouse-Hinds MTL Inc.
3413 N. Sam Houston Parkway W.
Suite 200, Houston TX 77086, USA
Tel: +1 281-571-8065
Fax: +1 281-571-8069
E-mail: mtl-us-info@eaton.com
Eaton Electric Limited,
Great Marlings, Butterfield, Luton
Beds, LU2 8DL, UK.
Tel: + 44 (0)1582 723633
Fax: + 44 (0)1582 422283
E-mail: mtlenquiry@eaton.com
www.mtl-inst.com
© 2016 Eaton
All Rights Reserved
Publication No. AN904-1002 Rev I 211016
October 2016
EUROPE (EMEA):
+44 (0)1582 723633
mtlenquiry@eaton.com
THE AMERICAS:
+1 800 835 7075
mtl-us-info@eaton.com
ASIA-PACIFIC:
+65 6 645 9888
sales.mtlsing@eaton.com
The given data is only intended as a product description and should not be
regarded as a legal warranty of properties or guarantee. In the interest of
further technical developments, we reserve the right to make design changes.
October 2016
AN1007 Rev B
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>