Roth 2897947 Shunt Unit for 7 Circuits Installation Guide

June 12, 2024
Roth

Roth ShuntUnit
Installation
Roth 2897947 Shunt Unit for 7 Circuits
Garman QUALITY SINCE 1947

Installation ShuntUnit

Ensure that all components are intact and then mount air vent, flow valve incl. thermostatic head and thermometer.Roth 2897947 Shunt Unit for 7
Circuits - fig Attach the mounting bracket to the wall or in the underfloor heating cabinet, so the shunt is placed horieontal.Roth
2897947 Shunt Unit for 7 Circuits - fig 1
lighten the underfloor heating pipes on to the manifold with the Roth 3/4 ‘EURO compression fitting.Roth 2897947 Shunt Unit for 7 Circuits - fig
2

Venting and flushing of the system must be done 1 pipe at a time.
Supply water to the top manifold before flushing water from lower mani- fold, and into the drain. Then set the desired pressure on in your system.Roth
2897947 Shunt Unit for 7 Circuits - fig 3Start the pump and let it run for 10 minutes on the pump auto air venting program. The shunt will let the air out through the air vent on the manifold top.Roth
2897947 Shunt Unit for 7 Circuits - fig 5  Set the pump on constant pressure, As shown in the photo on the right, this setting is the most sufficient to obtain optimal pressure and comfort in your system. The system will only function optimally when flow valve adjustment is done. Use the supplied key to make the settings on to the lower manifold valve. Roth 2897947 Shunt Unit for 7 Circuits - fig 4

If the pump is needed on the right side of the manifald, then separate and assemble the shunt in the shown order.![Roth 2897947 Shunt Unit for 7 Circuits

Expansion to additional circuit (optional)

Remove the end pcs
Mount the extension kit on to the manifold
Mount the end pcs again to finish
it is not necessary to use sealant or tape.Roth 2897947 Shunt Unit for 7
Circuits - fig 11

Guidance for balancing the manifold valves – Example, Flow rate valve pre- setting must start from a fully open valve.Roth 2897947 Shunt Unit for 7
Circuits - fig 19

Technical data

Roth ShuntUnit with 1 outlet. HVAC no. 7466212110
Roth ShuntUnit with 2 outlets. HVAC no. 7466212120
Roth ShuntUnit with 3 outlets. HVAC no. 7466212130
Roth ShuntUnit with 4 outlets. HVAC no. 7466212140
Roth ShuntUnit with 5 outlets. HVAC no. 7466212150
Roth ShuntUnit with 6 outlets. HVAC no. 7466212160
Roth ShuntUnit with 7 outlets. HVAC no. 7466212170
Roth ShuntUnit with 8 outlets. HVAC no. 7466212180
Roth Extension kit, 1 outlet HVAC no. 7466212766
Roth ShuntUnit insulation box HVAC no. 7401973891

LED
Steady green Led
Fast, green Led flashing
Red/green flashing
Red flashing
No LED light
Explanation
Pump is working normally
Air vent, program is on Abnormal situation, the pump is in shutdown mode Pump has stopped (potentially blocked) No power to the pump (check the power supply)

ROTH DANMARK A/S
• Tel. +45 47 38 01 21
• E-mail: service@roth-danmark.dk
• roth-danmark.dk ROTH SVERIGE AB
• Tel. +46 40 53 40 90
• E-mail: service@roth-sverige.se
• roth-sverige.se
ROTH NORGE AS
• Tel. +47 67 57 54 00 E-mail: service@roth-norge.no
• roth-norge.no ROTH FINLAND OY Puh. +358 (0) 19 440 330
• E-mail: service@roth-finland.fi
• roth-finland.fi ROTH UK Ltd.
Phone +44 (0) 1984 623982
• E-mail: sales@roth-uk.com
roth-uk.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Roth User Manuals

Related Manuals