GIANNI GEM Easiprox Plus Series Access Control Proximity Readers User Manual

June 12, 2024
GIANNI

GIANNI GEM Easiprox Plus Series Access Control Proximity Readers User Manual

GIANNI GEM Easiprox Plus Series Access Control Proximity Readers User
Manual

GIANNI GEM Easiprox Plus Series Access Control Proximity
Readers

Features:

  • Applicable card mode: EM Card / Key Fob
  • 1 Administrator and 200 Users
  • 200 Proximity Cards / Key fobs
  • Access Modes: Use Bluetooth smartphone or Card / Key fob to access
  • Built-in Tamper alarm and Buzzer (85dB)
  • User Management: Add / Delete / View user data, Grant user access for specific dates or time periods, Change user passcode
  • Audit Trail logs for last 1000 events
  • Alarm output to notify that Tamper alarm has been triggered
  • Overhead LEDs for easy use in the dark
  • IP65

Specifications:

  • Operating Voltage:
    Easiprox+ Slim: 12VDC
    Easiprox+: 12/24VDC

  • Bluetooth Module: BLE 4.2 Bluetooth Low Energy

  • Current Draw
    Easiprox Slim+: Standby current89mA@12VDC
    Working current (Relay active)103mA@12VDC
    Easiprox+: Standby current53mA@12VDC, 30mA/24VDC
    Working current (Relay active)60mA@12VDC, 34mA@24VDC

  • Read Range: 5cm

  • Frequency: EM 125KHz

  • Operating Distance: Up to 50 meters (164 ft) without blocking by metal or concrete wall / door frames

  • Smartphone Compatibility: Android 5.0 and up, iOS 9.0 and up

  • Finish: ABS

  • Temperature: -20 °C ~ 70 °C (-4 °F ~158 °F)

  • Dimension / Color:
    Easiprox+: 114 (L) x 80 (W) x 18 (D) mm / Navy Blue
    Easiprox+ Slim: 88 (L) x 44 (W) x 23 (D) mm / Black

Easiprox+ Series Pre-Installation

GIANNI GEM Easiprox Plus Series Access Control Proximity Readers - Easiprox
Series Pre-Installation

LED & Audible Indicators

GIANNI GEM Easiprox Plus Series Access Control Proximity Readers - LED &
Audible Indicators

Easiprox+ Series Wiring Diagram

GIANNI GEM Easiprox Plus Series Access Control Proximity Readers - Wiring
Diagram

Reset Procedures

  1. Power off Access Control Reader.
  2. Move the Pin Jumper to P2 and P3, then power on.
  3. Hear a long beep to complete resetting procedures.
  4. Move the Pin Jumper back to P1 and P2 to Normal setting.
  5. Login as Admin and check all users, audit trail events are all cleared and everything is reset to factory default setting, except device name.

Install Crimp Connectors

Crimp connectors included:

Use a pair of crimping pliers designed to crimp insulated connectors. Place the crimp connector into the compression slot. Be sure the crimping jaws are positioned over the stripped portion of the wire. Squeeze the handles together with enough force to crush the end of the butt splice.

Easiprox+ Reader Installation:

Easiprox+

1. Check and measure dimensions.
2. Connect the wires and mount the back cover by using 4pcs of anchor screws into the wall.
3. Install the front cover then install the bottom security screw. Finish installation.

Easiprox+ Slim

1. Check and measure dimensions.
2. Connect the wires and mount the base by using 4pcs of anchor screws into the wall.
3. Using 4pcs of screws to mount PCB case and the base.
4. Connect PCB Case and Front cover then install the bottom security screw. Finish installation.

Software App Operations

1. Download Easiprox App (for model Easiprox+ Series and DG Series)

http://onelink.to/vae3yt

Download Easiprox App to set up. Scan QR Code on the left or download the App from Apple Store or Google Play depending on what kind of smartphone you use. Smartphone compatibilityj Android 5.0 and up, iOS 9.0 and up

2. App Main Page Introduction

GIANNI GEM Easiprox Plus Series Access Control Proximity Readers - App Main
Page Introduction 1 GIANNI GEM Easiprox Plus Series Access Control Proximity
Readers - App Main Page Introduction 2

3. Administrator ” Settings” Page Introduction

GIANNI GEM Easiprox Plus Series Access Control Proximity Readers -
Administrator ” Settings” Page 1 GIANNI GEM Easiprox
Plus Series Access Control Proximity Readers - Administrator ” Settings” Page
2

  • Device Name : Edit Device Name (Up to 16 characters)

  • Admin Passcode : Edit Admin Passcode (4~8 digits)

  • Admin Card/Fob : Edit Admin Card/Fob number (10 numbers on your card or key fob)

  • Door Sensor
    Enable Door Sensor when you connect to a closed-circuit magnetic sensor or a monitored door
    lock that has door sensor (or lock sensor) outputs to monitor the open or closed state of a door.

  • Lock Action : (3 options)
    Choose Door Re-lock Time, Door Always Unlocked, and Door Always Locked.

  • Tamper Alarm
    If the device is vandalized, the tamper alarm will beep immediately and won’t go off until it’s switched off by Administrator.

  • Tamper Sensor Level
    Level 1 (High Sensitivity)
    Level 2 (Mid Sensitivity)
    Level 3 (Low Sensitivity)

  • Door Re-lock Time
    6 seconds by default. Edit the Door Re-lock Time interval between 1 to 1800 seconds.

  • Auto Proximity Range
    Adjust Auto Proximity Range here. The range is between 0 to maximum 20 and it may have different results under different circumstances.

  • Device Time
    Make sure the Device Time is precisely synced with your current time zone to have correct and precise access data and information.

  • About us: View Device Models, App version, Website and E-Mail information.

  • Firmware version: See Firmware version of your Bluetooth Access Control Keypads/Readers.

4. User’s ” Settings” Page Introduction

Tap “Settings” to view or change setting functions in User’s “Settings” Page. (See Figure 9 below)

  • Device Name: User can only view the Device Name. (See Figure 10 below)

  • Auto Proximity Range: User can adjust Auto proximity range between 0 to maximum 20 to access.
    May have different results under different circumstances. (See Figure 11 below)

  • About Us: View Device models, App version, Website information.

GIANNI GEM Easiprox Plus Series Access Control Proximity Readers - Fig.
9-11

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GIANNI User Manuals

Related Manuals