Anolis UVinere Remote 1/2/4 Installation Guide

June 12, 2024
ANOLiS

Anolis UVinere Remote 1/2/4 Installation Guide

INSTALLATION WITH STANDARD BRACKETS

STEP 1.A

Use fasteners that are appropriate for use with your mounting surface

  1. Drill two holes into the surface according the given dimensions(Eminere Remote 1/2/4) Fasten the Eminere Remote to the surface by two washers, spring washers and screws.e


  2. Loosen locking screws on both sides, adjust fixture to desired position and tighten locking screwson both side.

INSTALLATION WITH WALL MOUNT BRACKETS

STEP 1.B

Use fasteners that are appropriate for use with your mounting surface

  1. Drill two holes into the surface according the given dimensions(Eminere Remote 1/2/4) Fasten the Eminere Remote to the surface by two washers, spring washers and screws.

  2. Loosen locking screws on both sides, adjust fixture to desired position and tighten locking screws on both sides.

INSTALLATION WITH MOUNTING BRACKETS 100/200/300 MM

STEP 1.C

Use fasteners that are appropriate for use with your mounting surface

  1. Drill two holes into the surface according the given dimensions(Eminere Remote 1/2/4) Fasten the Eminere Remote to the surface by two washers, spring washers and screws.

  2. Loosen locking screws on both sides, adjust fixture to desired position and tighten locking screws on both sides.

CONNECTION

  1. Uncover E-box.

  2. Strip these lengths for cable connections.

| A
---|---
Power Connection| 9mm
Data Connection| 9mm

Connection – colour coding

LED Unit Connection – CE Leader

TERMINAL BLOCK VCC D+ D- 0V GROUND
Colour of Wire Red Orange White Black /

LED Unit Connection – US leader

TERMINAL BLOCK VCC D+ D- 0V GROUND
Colour of Wire Red Orange White Black Green/Yellow

Wiring connection

EU leader cable shown

US leader cable shown

Note for E-box Remote Basic.
If the Emineres Remote UV are connected to the LED output of the E-box Remote Basic, the last Eminere Remote has to be terminated by a terminator. The terminator is a 120 Ohm resistor connected between terminals D+ and D- in the last fixture.
If both LED outputs of the E-box Remote Basic are used, both lines of Emineres Remote have to be terminated by the 120 Ohm resistor.

CABLE GLAND INSTALLATION

Use wrench size 24 for cable gland M20x1.5

Apply Loctite 5331 thread sealant on the plastic holder and Loctite 577 thread locking compound on the gland body in the indicated locations prior to assembly.

Failure to properly install cable glands will result in failure of the water tight seal!

FILLING CONNECTION BOX WITH SYNTHETIC RESIN

After checking all connections, fill the connection box with synthetic resin. Make sure the end cap is inserted in any unused cable glands, and the earth ground wire is pulled from the junction box before filling it with resin. Read and follow all  instructions stated on the resin bag prior to filling the junction box. The connection box has to be fully filled by resin.

CLOSE CONNECTION BOX

Install top cover back.

INSTALLATION OF ACCESSORIES – BLACK GLASS ADAPTOR

Eminere Remote with black glass adaptor

  1. Place the black glass adaptor onto the fixture.

  2. Fasten the adaptor to the fixture with 4 screws.

ROBE lighting s. r. o.
Palackeho 416
757 01 Valasske Mezirici
Czech Republic
Tel.: +420 571 751 500
E-mail: info@anolis.eu
www.anolislighting.com