Roth Energylogic Projectline Wireless Control Installation Guide

June 12, 2024
Roth

Roth Touchline® SL Installation
Roth Touchlines SL Room sensor Mini Living full of energy

Energylogic Projectline Wireless Control

Roth Touchlines SL Room sensor Mini

Roth Energylogic Projectline Wireless Control - Fig 1 The sensor can be connected to all Controllers in the Touchline SI series. Pairing/registering is made the same way on all Controllers using the same buttons. On the pictures the panel of the Touchline* a Controller, master Is shown. Insert battery (CR2032 Included) as shown on the thawing.Roth
Energylogic Projectline Wireless Control - Fig 2Pairing/registering the sensor to a zone (channel). Follow step 2 to 7 and press pairing button as shown on step 8. Finish with Menu and after that press several times on Exit until standard view. All connections must be made to the Controller (pump, actuators and optionally potential free relay) before start-up. Please see controller manual for details. Roth Energylogic
Projectline Wireless Control - Fig 3Once the sensor is connected to the Zone/Channel, the overview shows: – Temperatures on the thermostat (setpoint 22,0°C, actual 25,0°C) , battery (99%), signal strenght (100% – must be at least 10%) and mode of operation (CON = continously). For more info on the display, see controller manual. Repeat registration for other sensors, by choosing one of the other zones (2 to 8) until required number of sensors are connected. ] Attention! If a sensor is paired to the wrong zone, do not delete the sensor. Pair the sensor to the correct/new zone and the old pairing will be deleted.Roth Energylogic Projectline Wireless Control - Fig
4Mount the lid and turn lightly (2 -3 mm) with a screwdriver or coin.![Roth Energylogic Projectline Wireless Control

  • Fig 5](https://manuals.plus/wp-content/uploads/2023/07/Roth-Energylogic- Projectline-Wireless-Control-Fig-5.jpg)First apply the self-adhesive tape (included) on the sensor, then the sensor on the wall. The ventilation grooves must point downwards.
    Settings for temperature and mode must be done on the controller’s display. For constant temperature settings follow the steps 13 – 19 below.Roth
Energylogic Projectline Wireless Control - Fig 6 If a different mode than constant temperature is wanted, for example time schedule or time limitation, then follow the below steps below 20 – 26 below. For more information about time schedules, we refer to the online manual for Roth Touchline® SL Controller — Master.Roth Energylogic
Projectline Wireless Control - Fig 7Picture 26, now shows the new setpoint 22,0°C and the remaining time for this temperature (01:59). When the time expires the system auto-matically returns to the original selected constant temperature (19°C).

https://rebrand.ly/ptvf6xe

ROTH UK Ltd| ROTH DANMARK A/S| ROTH SVERIGE AB| ROTH NORGE AS| ROTH FINLAND OY
---|---|---|---|---
 1a Berkeley Business Park
Wainwright Road Worcester WR4 9FA
Phone +44 (0) 1905 453424
E-Mail enquiries@roth-uk.com
technical@roth-uk.com
orders@roth-uk.com
accounts@roth-uk.com
roth-uk.com| Centervej 5
3600 Frederikssund
TIE +45 4738 0121
E-mail: service@roth-danmark.dk roth- danmark.dk| Hojdrodergatan 22
212 39 Malmo
Tel. +46 40534090
Fax +46 40534099
E-mail: service@roth-sverige.se roth- sverige.se| Billingstadsletta19
1396 Billingstad
Tel. +47 67 57 54 00
E-mail: service@roth-norge.no
roth-norge.no facebook.com/RothNorge| Raaseporintie 9 (Talo 2)
10600 Tammisaari
Puh. +35 (0)19 440 330
S-posti: service@roth-finland.fi
roth-finland.f
facebook.com/RothFinland

Installation Roth Touchline® SL sensor mini_20220401

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Roth User Manuals

Related Manuals