Roth Touchline SL Wireless Heat Control Thermostat Instruction Manual

June 12, 2024
Roth

Roth Touchline SL Wireless Heat Control Thermostat

Product Information

The Roth Touchline SL is a room thermostat designed for controlling underfloor heating systems. It features a floor sensor input and can be connected to a floor sensor (not included) for precise temperature control. The thermostat has a backplate that can be mounted on the wall, and the thermostat unit slides onto the backplate.

Key Features:

  • Compatible with underfloor heating systems
  • Floor sensor input for precise temperature control
  • Wall-mountable with included backplate

Product Usage Instructions

  1. Installation:

    • Insert the tip of a straight-edged screwdriver into the slot between the front and back of the thermostat and twist the parts apart.

    • If desired, connect a floor sensor to the thermostat by carefully pushing the wires into the clamp and screwing them on.
      The sensor must be pulled into the draw pipe and placed just below the upper floor covering, in the middle between the underfloor heating pipes.

    • Mount the backplate on the wall using the included screws, then slide the thermostat unit onto the backplate.

  2. Using the Floor Sensor:

    • In Comfort mode, the room sensor will have priority between the minimum and maximum temperature settings. Outside this range, the floor sensor has priority.
    • If the floor sensor is used for floor protection, it will stop heating if the temperature goes above the set maximum temperature. Below this temperature, the room sensor has priority.
  3. Button Lock:

    • To lock the buttons, press the Menu button, select Yes using the / buttons, and confirm by pressing the Menu button. Alternatively, wait for 5 seconds.
    • To unlock the buttons, press both the / and – buttons or wait for the display to show the lock symbol.
  4. Calibration Value:

    • The room thermostat can display a calibration value. Hold down the Menu button for 3 seconds to view the calibrated temperature. The calibration value can only be changed on the control unit under the relevant channel/zone.
  5. Deleting from Control Unit:

    • To delete the room thermostat from a control unit, press the Menu button for 3 seconds, release, and briefly press the Menu button again. Use the / buttons to change FAr to Yes, then press the Menu button or wait for 5 seconds to clear the thermostat from the control unit.
  6. Displaying Firmware Version:

    • To view the firmware version, press the Menu button for 3 seconds, release, and briefly press the Menu button twice.

If you have any further questions or need assistance, please contact the respective customer support:

ROTH UK Ltd

  • Address: 1a Berkeley Business Park Wainwright Road Worcester WR4 9FA
  • Phone: +44 (0) 1905 453424
  • Email: [email protected]

ROTH DANMARK A/S

Roth Touchline® SL Plus termostat

Roth-Touchline-SL-Wireless-Heat-Control-Thermostat-01

  1. Insert the tip of a straight-edged screwdriver into the slot between the front and the back and twist the parts apart.

  2. Insert batteries (included), be aware of +/- polarity.Roth-Touchline-SL-Wireless-Heat-Control-Thermostat-02

  3. It is possible to connect a floor sensor to the thermostat (floor sensor not included). Carefully push the wires into the clamp and screw them on. The sensor must be pulled into the draw pipe and the sensor end placed just below the upper floor covering, in the middle between the underfloor heating pipes.Roth-Touchline-SL-Wireless-Heat-Control-Thermostat-03

  4. Mount backplate on the wall (screws are incl.) thermostat slides onto back plate.

  5. The thermostat can be connected to all Controllers in the Roth Touchline® SL series. Pairing/registering is made the same way on all Controllers using the same buttons. On the pictures the panel of the Roth Touchline® SL Controller, master is shown.Roth-Touchline-SL-Wireless-Heat-Control-Thermostat-04

  6. Pairing/registering the thermostat to a zone (channel).

  7. All connections must be made to the Controller (pump, actuators and optionally potential free relay) before start-up. Please see controller manual for details.
    Attention! Do not press the buttons on the front of the thermostat whilst pushing the pairing button on the rear (see picture 11).
    Roth underfloor heating systemRoth-Touchline-SL-Wireless-Heat-Control-
Thermostat-05

  8. Once the thermostat is connected to the Zone/Channel, the overview shows:

  9. Temperatures on the thermostat (setpoint 22,0°C, actual 25,0°C) , battery (99%), signal strenght (appears with 4 lines, there must be a minimum of 1 line during installation) and mode of operation (CON = continously).

  10. For more info on the display, see controller manual.

  11. Repeat registration for other thermostats, by choosing one of the other zones (2 to 8) until required number of thermostas are connected.
    Attention! If a thermostat is paired to the wrong zone, do not delete the thermostat. Pair the thermostat to the correct/new zone and the old pairing will be deleted.

  12. If the thermostat has a floor sensor connected, this must also be paired/registered as shown below (picture 21, must be two quick presses). Roth-Touchline-SL-Wireless-Heat-Control-Thermostat-06

  13. In the overview you can see both the thermostat (setpoint 22,0°C, actual 25,0°C) and the actual floor temperature (21,0°C).

  14. Repeat this for all other zones/channels (2 to 8) with a floor sensor. Roth-Touchline-SL-Wireless-Heat-Control-Thermostat-07

  15. Operation/setting of the floor sensor is carried out on the display of the Controller.

  16. Floor sensor operation can be set up as either “Floor protection” (standard) or “Comfort” (min. Floor temp.).

  17. Set sensor as “Floor protection”.

  18. Choose operation mode and choose “Floor protection”.

  19. Set max. floor temperature to protect your floor.

  20. Confim with “Menu”.

  21. Set sensor as “Comfort”.

  22. Choose operation mode and choose “Comfort”.

  23. Set min. floor temperature for your comfort level

  24. . Confirm with “Menu”. Min. temperature is set as described above. Roth-Touchline-SL-Wireless-Heat-Control-Thermostat-08 Roth-Touchline-SL-Wireless-Heat-Control-Thermostat-09 Roth-Touchline-SL-Wireless-Heat-Control-Thermostat-10 Roth-Touchline-SL-Wireless-Heat-Control-Thermostat-11

Attention! Using the floor sensor as “Floor protection”, the sensor will stop heating if the temperature goes above the set max. temperature. Below this temperature the room sensor has priority. Using the floor sensor in “Comfort” mode, the room sensor will have priority between min. and max. setting. Outside this min/max setting the floor sensor has priority

| SE
---|---
| In sleepmode the current temperature is displayed. To set/change temperature press Ú / Ù buttons.

Confirm by pressing Menu.

|
| You can switch between temperature display and relative humidity display by briefly pressing the Exit button.|
| How to lock the buttons. Press “Menu“ Select “Yes“ using one of the Ú / Ù buttons and confirm by pressing “Menu“ or wait 5 seconds.

When the lock is active, the keys are locked automati- cally after 10 seconds of inactivity.

Unlock by pressing both

Ú / Ù buttons for 5 sec. The keys are available when the display does not show the lock. The lock is active until you deactivate it in the menu.

|
| The room thermostat can show calibration value. Hold down “Menu“ for 3 sec. The display shows “Cal“ and the calibrated temperature. The value can ONLY be changed on the control unit, under the relevant channel/zone. It can take up to 5 minutes before the calibrated temperature is displayed.|

| The room thermostat can be deleted from a control unit by pressing “Menu“ for 3 sec., Release and briefly press “Menu“ again.

FAr is set to NO by default, to change this use “Ú / Ù“. At “Yes“ press “Menu“ or wait 5 sec and the ther- mostat is cleared from the control unit.

|

| The room thermostat can display the firmware version, by pressing “Menu“ for 3 sec., Release and press twice briefly on “Menu“.|

Roth-Touchline-SL-Wireless-Heat-Control-Thermostat-19

  UK
1 Manual mode
2 Battery level
3 Pre-set temperature
4 Button lock
5 Wi-Fi signal strength
6 Current temperature
7 Heating/Cooling

Roth Touchline® SL
QR

ROTH DANMARK A/S
Centervej 5
3600 Frederikssund
Tlf. +45 4738 0121
E-mail: [email protected] roth- danmark.dk

ROTH SVERIGE AB
Höjdrodergatan 22
212 39 Malmö
Tel. +46 40534090
Fax +46 40534099
E-mail: [email protected] roth- sverige.se

ROTH NORGE AS
Billingstadsletta 19
1396 Billingstad
Tel. +47 67 57 54 00
E-mail: [email protected] roth- norge.no
facebook.com/RothNorge

ROTH UK Ltd
1a Berkeley Business Park Wainwright Road
Worcester WR4 9FA
Phone +44 (0) 1905 453424
E-Mail [email protected] technical@roth- uk.com [email protected] [email protected] roth-uk.com

ROTH FINLAND OY
Raaseporintie 9 (Talo 2) 10600 Tammisaari
Puh. +358 (0)19 440 330
S-posti: [email protected] roth- finland.fi
facebook.com/RothFinland

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Roth User Manuals

Related Manuals