SCOPREGA GE25 Series Electric Inflator Instruction Manual

June 12, 2024
SCOPREGA

SCOPREGA GE25 Series Electric Inflator

SCOPREGA GE25 Series Electric Inflator

FUNCTIONAL DESCRIPTION

Functional Description

GE 25 SL / GE 25 HP

  1. MAIN SWITCH (FOR GE 25 AC ONLY)
  2. ON-OFF BUTTONS
  3. PRESSURE SETTING GAUGE WITH LIGHT INDICATOR
  4. OUTLET (INFLATE) PORT
  5. INLET (DEFLATE) PORT
  6. 110-240V POWER UNIT SOCKET (FOR GE 25 SL ONLY)
  7. 40 A FUSE
  8. 120V-60HZ OR 230V-50HZ POWER CABLE (FOR GE 25 AC ONLY)
LED COLOUR MEANING
GREEN LED ON AND BATTERY CHARGED
YELLOW LED PARTIALLY LOW BATTERY
RED LED OVERHEATING. THE DEVICE STOPS
RED LED COMPLETELY LOW BATTERY. PRESS OFF BUTTON.

FOREWORD

Dear customer,

congratulations on choosing Scoprega.

We design and manufacture products of the highest quality to meet the needs of our customers. Scoprega offers the highest quality in service as well. Our specialised departments provide support and instructions when needed, as well as comprehensive technical service.

We thank you for your trust.

WARNING

Read these instructions before using the inflator. Failure to follow all the instructions listed below may result in damage to the product and/or cause serious injury to persons.

PRELIMINARY WARNINGS

  1. Comply with all instructions in this document.
  2. Keep these instructions.
  3. Do not reverse the polarised terminals of the battery. Red is positive, black is negative.
  4. Always protect the power cable.
  5. Do not open the inflator. Refer all servicing to qualified service personnel authorised by Scoprega. Servicing is required when the device is damaged or not working in any way.
  6. Do not tamper with the product. Opening the inflator will void its warranty.
  7. Provide suitable ventilation.
  8. Avoid placing objects near the product during operation.
  9. Keep this product out of the reach of children.
  10. The operating inflator produces vibrations: therefore, we recommend you to use it on the floor, so as to avoid accidental falls.
  11. Do not burn or destroy the battery even if seriously damaged or completely flat. The battery could catch fire. Refer to the local authorities for proper disposal.
  12. Do not use the battery in case of fluid leakage. Bring it to the nearest authorised service centre.
  13. Do not try and open the battery. Do not use if the plastic housing shows signs of damage and do not recharge.

DO NOT POWER THE INFLATOR WITH A VOLTAGE HIGHER THAN 13V.

GENERAL SAFETY RULES

  1. ALWAYS TAKE INTO ACCOUNT THE WORKING ENVIRONMENT.
    Do not expose the inflator to rain. Do not use in the presence of flammable liquids or gases.

  2. AVOID UNINTENTIONAL STARTING.
    Do not start the inflator with the inlet in contact with dust or water.

  3. PAY ATTENTION.
    Pay attention to what you are doing. Use common sense.

  4. CHECK THAT THERE ARE NO DAMAGED PARTS.
    Before using the inflator, carefully check its outer sides and components.

  5. DO NOT OPERATE portable inflators near flammable liquids or in gaseous or explosive
    atmospheres. The inflator motors produce sparks that can release fumes.

  6. DO NOT INHALE!
    The compressed air coming from the inflator is not clean. Never inhale air from your inflator.

  7. WARNING! RISK OF EXPLOSION.
    Inflate the inflatable unit only complying with the manufacturer’s recommendations. Exceeding the
    pressure rating could cause the inflator to explode, resulting in personal injury.

  8. NEVER LEAVE THE DEVICE UNATTENDED.
    Over inflation could result in serious injury and property damage.

  9. WARNING! RISK OF UNSAFE OPERATION.
    Do not modify or attempt to repair the unit. Do not drill into or make any modifications to the inflator or its accessories. Any modification to the product will void its warranty.

  10. Never carry the inflator by the flexible hose or power cable.

BATTERY USE RULES (GE 25 SL and GE 25 HP)

  1. For best performance, charge the battery when the ambient temperature is between 18°- 24°C (65°F – 75°F). DO NOT charge the battery with temperatures below +4.5°C (+40°F), or above +40.5°C (+105°F). This will prevent serious damage to the battery.

  2. The charger and battery may become warm to touch while charging. This is a normal condition, and does not indicate a problem.

  3. DO NOT immerse the charger in water or any other liquids.
    KEEP THE CHARGER AWAY FROM ALL LIQUIDS. IT MAY CAUSE A SHORT CIRCUIT

  4. DO NOT try to charge the battery with any chargers other than those provided. The charger and battery are specifically designed to work together.

  5. The charger is not intended for any use other than charging the inflator battery. Any other use may result in risk of fire, electric shock or short circuit.

  6. Make sure that the cable is located so as it will not be stepped over, torn or damaged.

  7. Do not operate the charger with a damaged cable or plug.

  8. Do not operate the charger if it has received a sharp blow, been dropped or damaged in any way.

  9. Do not disassemble the charger. Incorrect reassembly can result in a risk of electric shock, short circuit or fire.

  10. Never use other chargers to charge this device. Always use original spare parts only.

  11. TO OPERATE THE INFLATOR FOR THE FIRST TIME, INSERT THE FUSE LOCATED INSIDE THE CARRY BAG.

  12. Fully charge the battery and disconnect the fuse when inflator is to be left unused for over 30 days.

  13. Recharge time for GE 25 HP: 2.5 hours vs 8 hours of previous versions. Recharge time for GE 25 SL: 16 hours.

INTRODUCTION

The GE 25 is a next-generation high-efficiency portable electric inflator, which stands out for reliability and functionality. The inflator features 2 stages that can be identified by the different noise: turbine noise at the beginning and piston noise later on. Turbine stage automatically switches to piston stage. The inflator starts when the ON button is pressed and automatically stops when the set pressure in the pressure gauge is reached. The device stops when the user presses the OFF button. The GE 25 SL and GE 25 HP are fully portable inflators as the battery is integrated in the device. When the battery is low (red light on pressure gauge), it can be recharged using 110-240 AC/DC transformers.

The GE 25 AC requires a 120 V – 60 Hz or 230V – 50 Hz power supply, as specified on the nameplate.

The unit is protected against overheating. In the event of high outside temperature or overuse, the inflator will automatically stop and a red LED on the pressure gauge will indicate its status. The device can be restarted when the red LED goes OFF

RECOMMENDED USES

Large inflatable objects such as surfboards / rubber dinghies / kayaks / kites / etc. rafts / air mattresses / swimming pool floats / etc.

TECHNICAL SPECIFICATIONS

ITEM| FLOW RATE

(L / minute)

| SAFETY FUSE| MAX. PRESSURE

(mbar)

| FUNCTIONS
---|---|---|---|---
GE 25 SL| 425 (fan)

250 (compressor)

| 40 A| 1500 (22 PSI)| INFLATION / DEFLATION
GE 25 HP| 425 (fan)

250 (compressor)

| 40 A| 1500 (22 PSI)| INFLATION / DEFLATION
GE 25 AC| 425 (fan)

250 (compressor)

| 40 A| 1500 (22 PSI)| INFLATION / DEFLATION

Pressure settings Pressure gauge with automatic switching of
Battery charger socket Jack type (for GE 25 SL and GE 25 HP only)
Power cable 3 m long cable (for GE 25 AC only)
Inflation fittings Available for most common valves
Carry bag dimensions 395x180x240 mm
GE 25 SL batteries No. 2 Sealed Lead-Acid Batteries – 12V 9Ah
GE 25 HP batteries No. 2 LiFePO4 Batteries – 12.8V 8Ah

INFLATOR USE

ACCESSORIES AND POWER CABLES

  1. 1. Accessories, like the 110-240V battery charger and the relevant adapters, can be found in the top compartment of the carry bag.
    CONNECTION

  2. Ensure that the OFF button has been pressed (LED off on pressure gauge) and that the main switch is off (GE 25 AC only).

  3. Connect the air hose to the inflate port (OUT) or to the deflate port (IN), making sure that the tabs are properly fastened (see picture)

  4. Assemble the most suitable adapter for the inflator valve.

TO INFLATE

  1. Connect the hose to the outlet port (OUT)
  2. Set the desired pressure on the pressure switch.
  3. For GE 25 AC only: press the main switch (point 1, fig. on p.3) For GE 25 SL and GE 25 HP: press the ON button (point 2, fig. on p.3)
  4. The device starts and the LED on pressure gauge becomes GREEN. The inflator will automatically stop when the float reaches set pressure.

TO DEFLATE

  1. Connect the hose to the inlet port (IN)
  2. Set the pressure on the pressure switch to zero.
  3. For GE 25 AC only: press the main switch (point 1, fig. on p.3) For GE 25 SL and GE 25 HP: press the ON button (point 2, fig. on p.3)
  4. The device starts and the LED on pressure gauge becomes GREEN.
  5. Press the OFF button as soon as the float is completely deflated.

WARNING

DEFLATION DOES NOT STOP AUTOMATICALLY. SWITCH OFF THE INFLATOR ONCE THE INFLATABLE UNIT IS COMPLETELY EMPTIED

WARNING

(for GE 25 SL and GE 25 HP only): If the LED on pressure gauge becomes YELLOW or RED, press the OFF button, connect the inflator to recharge the battery.

Be careful when connecting the cable to the battery, in order not to short the battery with conducting materials such as rings, bracelets and keys. The battery or adapter may overheat and cause injury

Check the voltage. Do not connect the 12V inflator to a 24V battery.

Do not leave the inflator running unattended. Overinflating an object could result in serious injury.

THE INFLATOR CAN BE DAMAGED BY SAND, DUST OR WATER GETTING INSIDE THE INLET PORT. THIS WILL CAUSE OVERHEATING AND WILL DAMAGE THE TURBINE. SHOULD THIS BE THE CASE, IMMEDIATELY SWITCH THE INFLATOR OFF.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION
**** The inflator does not start **** GE 25 SL/GE 25 HP battery LOW ****

Recharge the battery using the 110-240V battery charger.
The ON button has not been pressed.| Press the ON button.
The safety fuse is blown| Replace the fuse with one of the same type (30 A)
The device is damaged| Contact a SCOPREGA service centre.
The inflator does not inflate/ deflate| Hose wrong connection.| Connect the air hose to the correct port.
Wrong pressure setting| Correct pressure setting.
Battery LOW with yellow or red LED ON| **** Recharge the battery using the 110-240V battery charger.

ACCESSORY WARNING

The recommended accessories when using the inflator are the original SCOPREGA ones.
The use of any accessory not recommended for this inflator can be dangerous.

Documents / Resources

| SCOPREGA GE25 Series Electric Inflator [pdf] Instruction Manual
GE25 HP K6130950, GE25 SL K6130900, GE25 AC 230V - K6130990, 120V - K6130980, GE25 Series Electric Inflator, GE25 Series, GE25 Series Inflator, Electric Inflator, Inflator
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SCOPREGA User Manuals

Related Manuals