SCOPREGA Turbo Max 12v For Inflatables Electric Inflator
Product Information
The TURBO MAX is an electric inflator that operates on 12V or 24V. It can inflate large objects such as rafts, tents, and boats. The inflator comes with the following features:
- On-off/start switches
- Pressure adjustment knob
- Status LED
- Inflation nozzle (out)
- Deflation nozzle (in)
- Safety fuse
- Power cable with 12/24V clamps
- Inflation hose
The TURBO MAX has a maximum flow rate of 1000 liters/minute and a maximum pressure of 250 mbar.
Product Usage Instructions
- Ensure that the inflator is not exposed to rain or used in the presence of flammable liquids or gases.
- Avoid accidental starting by not starting the inflator with the input nozzle in contact with dust or water.
- Before using the inflator, check the status LED for the battery charge level and ensure that the battery voltage is within the specified range in the technical data section of the manual.
- Connect the inflation hose to the out nozzle and turn on the inflator using the on-off/start switches to inflate an object. Use the pressure adjustment knob to set the desired pressure.
- Connect the deflation nozzle to the in the nozzle and turn on the inflator using the on-off/start switches to deflate an object.
- After use, turn off the inflator and disconnect the power cable from the battery. Store the inflator and its accessories in a dry and safe place.
FUNCTIONAL DESCRIPTION
TURBOMAX
- MAIN SWITCHES (on-off / start)
- PRESSURE SETTING KNOB
- LED INDICATORS
- DEFLATION PORT (IN)
- INFLATION PORT (OUT)
- SAFETY FUSE
- CABLE WITH 12/ 24V POWER CLAMPS
- INFLATION HOSE
FOREWORD
Dear customer,
congratulations on choosing Scoprega.
We design and manufacture products of the highest quality to meet the needs of
our customers. Scoprega offers the highest quality in service as well. Our
specialized departments provide support and instructions when needed, as well
as comprehensive technical service.
We thank you for your trust.
WARNING
Read these instructions before using the inflator. Failure to follow all
the instructions listed below may result in damage to the product and/or cause
serious injury to persons.
PRELIMINARY WARNINGS
- Comply with all instructions in this document.
- Keep these instructions.
- Do not block the air vents (SEE FIGURE ON PAGE 3).
- Always protect the power cable.
- Do not open the inflator. Refer all servicing to qualified service personnel authorized by Scoprega. Servicing is required when the device is damaged or not working in any way.
- Do not tamper with the product. Opening the inflator will void its warranty.
- Provide suitable ventilation
- Avoid placing objects near the product during operation.
- Keep this product out of the reach of children.
- The operating inflator produces vibrations: therefore, we recommend you to use it on the floor, so as to avoid accidental falls.
INTRODUCTION
The TURBO MAX is a high-efficiency portable electric inflator, which stands for reliability and functionality. The TURBO MAX is equipped with two powerful DC motors that drive two turbines connected in series, thus allowing any object to be inflated to a pressure between 175 and 250 mbar. The inflator is equipped with LED indicators checking pump status during operation. The inflator starts when the ON button is pressed and automatically stops when the set pressure on the knob (2) is reached. The device stops when the user presses the OFF button.
RECOMMENDED USES
Large inflatable objects (rubber dinghies/tents/rafts).
TECHNICAL SPECIFICATIONS
ITEM| VOLTAGE
(V)| FLOW RATE
(L/minute)| MAX. PRESSURE
(mbar)| POWER CONSUMPTION
(A)
---|---|---|---|---
TURBO MAX 12V| 9.5 ÷ 14.5| 1000| 250| 70
TURBO MAX 24V/S| 19.5 ÷ 28.5| 1000| 250| 35
TURBO MAX KIT 12V| 9.5 ÷ 14.5| 1000| 250| 70
TURBO MAX KIT 24V-EV| 19.5 ÷ 28.5| 1000| 250| 35
GENERAL SAFETY RULES
-
ALWAYS TAKE INTO ACCOUNT THE WORKING ENVIRONMENT.
Do not expose the inflator to rain. Do not use it in the presence of flammable liquids or gases. -
AVOID UNINTENTIONAL STARTING.
Do not start the inflator with the inlet in contact with dust or water. -
PAY ATTENTION.
Pay attention to what you are doing. Use common sense. -
CHECK THAT THERE ARE NO DAMAGED PARTS.
Before using the inflator, carefully check its outer sides and components. -
DO NOT OPERATE portable inflators near flammable liquids or in gaseous or explosive atmospheres. The inflator motors produce sparks that can release fumes.
-
DO NOT INHALE!
The compressed air coming from the inflator is not clean. Never inhale air from your inflator. -
WARNING! RISK OF EXPLOSION.
Infl ate the unit only complying with the manufacturer’s recommendations. Exceeding the pressure rating could cause the inflator to explode, resulting in personal injury. -
NEVER LEAVE THE DEVICE UNATTENDED.
Overinflation could result in serious injury and property damage. -
WARNING! RISK OF UNSAFE OPERATION
Do not modify or attempt to repair the unit. Do not drill into or make any modifications to the inflator or its accessories. Any modification to the product will void its warranty. -
Never carry the inflator by the flexible hose or power cable.
LED INDICATORS
The inflator is equipped with two LED indicators (A and B) that allow the battery status and the pump temperature to be checked. LED A indicates the operating errors that have stopped the inflator operating cycle (refer to paragraph Infl ator and Battery Status Monitoring). LED B indicates the battery charging status.
USE AND OPERATION
ACCESSORIES AND POWER CABLES
- TURBO MAX 12V and TURBO MAX 24V/S versions: the inflation hose, adapters, and cable with clamps are located inside the carry bag.
- TURBO MAX KIT 12V and TURBO MAX KIT 24V-EV versions: as they are intended for a permanent installation, brackets and retaining screws are provided. The power cable is 50 cm long and is wired with a 100 A connector. The inflation hose and valve fittings are supplied only upon request.
Adapters for bayonet valves are available as an optional feature (see catalogue).
CONNECTING THE ACCESSORIES
- Choose the most suitable adapter for the valve on the object to be inflated. During inflation/deflation, the valve should be kept open by a suitable adapter.
- Make sure that the main switch is set to OFF.
- Connect the inflation hose according to the operation to be performed: to infl ate (connect to the OUT outlet), to defl ate (connect to the IN outlet).
- Insert the adapter into the valve of the object to be inflated/deflated.
TURNING ON THE INFLATOR
- Connect clamps to the battery or, for KIT versions, make sure that the power connectors are properly assembled
- Always stretch the electric cable.
- Set the desired inflation pressure (value between 175 and 250 mbar).
- Set the switch to ON. LED B starts flashing, indicating battery status (refer to paragraph Inflator and Battery Status Monitoring)
- Press the START switch. LED B shifts from flashing to steady, the color depends on the battery status
- When inflating, the inflator will stop at the set pressure and LED B will resume flashing
- In the event of an error, the inflator stops as a protective measure. LED A lights up to indicate the type of problem (refer to paragraph Inflator and Battery Status Monitoring). Once the problem has been fixed, the inflator should be restarted by pressing START.
- To deflate, connect the hose to the IN outlet and set the pressure setting knob to 175 bar.
WARNING
In case crocodile clips are used, make sure of the correct polarity (red
clamp connected to battery-positive terminal). Otherwise, the infl ator will
not start.
ACCESSORY WARNING
The recommended accessories when using the infl ator are the original SCOPREGA
ones. The use of any accessory not recommended for this infl ator can be
dangerous.
INFLATOR AND BATTERY STATUS MONITORING
LED A | LED B | STATUS | POSSIBLE SOLUTION |
---|---|---|---|
OFF | OFF | OFF | |
Flashing GREEN | OFF | Standby, CHARGED battery | |
Flashing YELLOW | OFF | Standby LOW battery | We recommend you to charge the |
battery before operating.
Flashing RED| OFF| Standby LOW battery| Charge the battery
Steady GREEN| OFF| Operating CHARGED battery|
Steady YELLOW| OFF| Operating LOW battery| We recommend you to charge the
battery before operating.
Steady RED| OFF| Operating LOW battery| Charge the battery
RED
flashing
| RED| CYCLE END due to LOW battery| Charge the battery and then press START
to restart the inflator
Flashing GREEN|
RED
| CYCLE END due to UNDERVOLTAGE or OVERVOLTAGE
Voltage below permitted limits
|
Make sure that the battery voltage complies with the values indicated in paragraph TECHNICAL FEATURES
Flashing (colour depends on the
battery status)
| RED flashing| CYCLE END due to OVERTEMPERATURE| Only after the LED indicators have stopped flashing can the inflator be restarted by pressing START
WARNING
-
WARNING
When connecting the power cable to the battery, make sure to avoid short circuits and possible fi re risk -
WARNING
Check the voltage. Do not connect the 12V infl ator to a 24V battery. -
WARNING
Do not leave the inflator running unattended. Overinflating an object could result in serious injury. -
WARNING
Always check the maximum inflation pressure to avoid risks of explosion.
TROUBLESHOOTING
PROBLEM | POSSIBLE CAUSE | POSSIBLE SOLUTION |
---|---|---|
The inflator does not start | Power cable not properly connected. | Connect the |
power cable correctly and with the right polarity (red clamp to battery
positive terminal).
Undervoltage in battery.| Check battery conditions.
Overvoltage in battery.| Check battery conditions.
The ON button has not been pressed.| Press the ON key.
The safety fuse is blown.| Replace the fuse with one of the same type (40 or
70 A).
The device is damaged| Contact a SCOPREGA service centre.
The inflator does not inflate
| Hose wrong connection.| Connect the air hose to the correct port.
Wrong pressure setting.| Correct pressure setting.
Switch not in the START position.| Set main switches to ON and then press
START.
ONLY FOR TURBOMAX KIT 12V and TURBOMAX KIT 24V-EV
ASSEMBLING THE CONNECTOR
-
Put the lids and the red grommets onto the cable ends (fig. 1).
After crimping the faston, we recommend you to tin the cable end to the connector to ensure current flow (fig. 1 – arrow). -
Insert the fastons into their seats, checking coupling tooth (fig. 2) and polarity (fig. 4).
-
Insert the grommets and the lids into their seats (fig. 3).
POWER CABLE
The cable section of the on-board supply system should be suitable for its length: -
For cable length up to 6 meters: 10 mm2 section
-
For cable length from 6 to 12 meters: 16 mm2 section
FASTENING THE INFLATOR
The inflator can be fastened onto the boat by means of the supplied “B”
brackets (fig. 5). Otherwise, it can be wall-mounted after drilling a hole (fig.
6), by fastening it to the “A” holes (fi g. 5) by means of Ø 4.5 mm self-
threading screws. The maximum screw length inside the inflator is 8 mm
.
PREPARING THE INFLATION HOSE
Cut the hose to the desired size. Insert the red fitting into one of the hose
ends to connect it to the inflator. At the opposite end, insert and glue the
soft PVC reduction unit. Then insert the valve fitting, taking care to select
from the kit supplied the one that allows the valve to open fully.