SCOPREGA GE20-2 Electric air pump Instruction Manual
- June 4, 2024
- SCOPREGA
Table of Contents
GE20-2
K6130702
ELECTRIC INFLATOR
SAVE THIS INSTRUCTIONS MANUAL FOR REFERENCE
FUNCTIONAL DESCRIPTION
GE 20-2
- ON – OFF BUTTONS
- PRESSURE SETTING GAUGE WITH LIGHT INDICATOR
- OUTLET (INFLATE) PORT
- AIR HOSE WITH ADAPTERS
- INLET PORT / AIR VENT
- 110-240V ADAPTER
- CABLE WITH 12V POWER CLAMPS
- CABLE WITH 12V CIGARETTE LIGHTER SOCKET
WARNING
This inflator is not to be used for deflating operations.
MANUAL OF
SAVE THIS INSTRUCTIONS MANUAL FOR REFERENCE
FOREWORD
Dear customer,
congratulations on choosing Scoprega.
We design and manufacture products of the highest quality to meet the needs of
our customers. Scoprega offers the highest quality in service as well. Our
specialized departments provide support and instructions when needed, as well
as comprehensive technical service.
We thank you for your trust.
WARNING
Read these instructions before using the inflator. Failure to follow all the
instructions listed below may result in damage to the product and/or cause
serious injury to persons.
PRELIMINARY WARNINGS
- Comply with all instructions in this document.
- Keep these instructions.
- Do not block the air vents (No.5 ON PAGE 3).
- Always protect the power cable.
- Do not open the inflator. Refer all servicing to qualified service personnel authorized by Scoprega. Servicing is required when the device is damaged or not working in any way.
- Do not tamper with the product. Opening the inflator will void its warranty.
- Provide suitable ventilation
- Avoid placing objects near the product during operation.
- Keep this product out of the reach of children.
- The operating inflator produces vibrations: therefore, we recommend you to use it on the floor, so as to avoid accidental falls.
NOTE This inflator is not to be used for deflating operations.
**** DO NOT POWER THE INFLATOR WITH A VOLTAGE IS HIGHER THAN THE RATED ONE.
GENERAL SAFETY RULES
-
ALWAYS TAKE INTO ACCOUNT THE WORKING ENVIRONMENT.
Do not expose the inflator to rain. Do not use in the presence of flammable liquids or gases. -
AVOID UNINTENTIONAL STARTING.
Do not start the inflator with the inlet in contact with dust or water. -
PAY ATTENTION.
Pay attention to what you are doing. Use common sense. -
CHECK THAT THERE ARE NO DAMAGED PARTS.
Before using the inflator, carefully check its outer sides and components. -
DO NOT OPERATE portable inflators near flammable liquids or in gaseous or explosive atmospheres. The inflator motors produce sparks that can release fumes.
-
DO NOT INHALE!
The compressed air coming from the inflator is not clean. Never inhale air from your inflator. -
WARNING! RISK OF EXPLOSION.
Inflate the unit only complying with the manufacturer’s recommendations. Exceeding the pressure rating could cause the inflator to explode, resulting in personal injury. -
NEVER LEAVE THE DEVICE UNATTENDED.
Overinflation could result in serious injury and property damage. -
WARNING! RISK OF UNSAFE OPERATION
Do not modify or attempt to repair the unit. Do not drill into or make any modifications to the inflator or its accessories. Any modification to the product will void its warranty. -
Never carry the inflator by the flexible hose or power cable.
BATTERY USE RULES
-
To operate the inflator for the first time, insert the fuse located inside the carry bag.
-
Perform a complete battery charge cycle (lasting 8 hours).
-
For best performance, charge the battery when the ambient temperature is between 18°- 24°C (65°F – 75°F). DO NOT charge the battery with temperatures below +4.5°C
(+40°F), or above +40.5°C (+105°F). This will prevent serious damage to the battery. -
The charger and battery may become warm to the touch while charging. This is a normal condition and does not indicate a problem.
-
DO NOT immerse the charger in water or any other liquids.
**** KEEP THE CHARGER AWAY FROM ALL LIQUIDS. IT MAY CAUSE A SHORT CIRCUIT -
DO NOT try to charge the battery with any chargers other than those provided. The charger and battery are specifically designed to work together.
-
The charger is not intended for any use other than charging the inflator battery. Any other use may result in risk of fire, electric shock or short circuit.
-
Make sure that the cable is located so as it will not be stepped over, torn or damaged.
-
Do not operate the charger with a damaged cable or plug.
-
Do not operate the charger if it has received a sharp blow, been dropped or damaged in any way.
-
Do not disassemble the charger. Incorrect reassembly can result in a risk of electric shock, short circuit or fire.
-
Never use other chargers to charge this device. Always use original spare parts only.
INTRODUCTION
The GE 20-2 is a next-generation high-efficiency portable electric inflator,
which stands for reliability and functionality. The GE 20-2 is equipped with a
double-piston pumping unit that allows any object to be inflated to a pressure
between 10 and 1,500 mbar. The inflator starts when the ON button is pressed
and automatically stops when the set pressure in the pressure gauge is
reached. The device stops when the user presses the OFF button.
The GE 20-2 is fully portable as the battery is integrated in the device. When
the battery is low (red light on the pressure gauge), the inflator can be
connected to a cigarette lighter socket or to an external 12V battery via the
power clamps. The battery can also be charged by a 12V cigarette lighter
socket or 110-240 AC/DC adapters.
The inlet port is protected by a multilayer filter, the outlet port is
equipped with a check valve.
The unit is protected against overheating. In the event of high outside
temperature or overuse, the inflator will automatically stop and a red LED on
the pressure gauge will indicate its status. The device can be restarted when
the red LED goes OFF.
RECOMMENDED USES
Inflatable items, such as: SUPs / Small rubber dinghies (3/4 m) / Kayak / Kites / Rafts / Air mattresses / Swimming pool floats / etc.
TECHNICAL SPECIFICATIONS
ITEM| FLOW RATE
(L / minute)| SAFETY FUSE| MAX. PRESSURE
(mbar)| FUNCTIONS
---|---|---|---|---
GE 20-2| 125| 30 A| 1,500 (22 PSI)| INFLATION
PRESSURE SETTINGS: PRESSURE GAUGE WITH AUTOMATIC SWITCHING OFF
INFLATION FITTINGS: AVAILABLE FOR MOST COMMON VALVES
CARRY BAG DIMENSIONS: 220x320x220 mm
USE FOR INFLATING
ACCESSORIES AND POWER CABLES
- All accessories are located inside carry bag upper compartment: inflation hose, power cables, and
battery charger.
CONNECTING THE ACCESSORIES
- The inflator is supplied with standard conical adapters that are located inside carry bag upper compartment.
- Make sure that the OFF button has been pressed.
- Take the hose from the carry bag.
- Connect the air hose to the port to inflate (OUT).
- Assemble the most suitable adapter for the inflator.
TURNING ON THE INFLATOR
-
To INFLATE, connect the hose to the outlet port (N3 fig. on p.3).
-
Set the desired pressure on the pressure switch (N2 fig. on p.3). The inflator will automatically stop when the set pressure is reached.
-
The device starts when the ON button is pressed. Depending on the battery level, the pressure gauge
LED will show three different colours: GREEN: charged battery.
YELLOW: battery running low.
RED: battery low.
When the LED is not GREEN, we recommend you to recharge before operating. Otherwise, the inflator can be used by connecting it to a car cigarette lighter socket (N8 on p.3) or to an external battery via a cable with power clamps (N7 on p.3).
NOTE The inflator battery will not be charged when using the cigarette lighter cable or the power terminal cable. -
If the LED on the pressure gauge turns YELLOW, press the OFF button and connect the inflator to a car cigarette lighter socket or an external battery via cable and power clamps.
-
If the LED on the pressure gauge turns RED, press the OFF button and connect the inflator to an external battery via cable and power clamps.
WARNING
Make sure polarity is correct (red terminal to positive). Otherwise, the
inflator WILL NOT START.
WARNING
Be careful when connecting the cable to the battery, in order not to short the
battery with conducting materials such as rings, bracelets and keys. The
battery or adapter may overheat and cause injury.
WARNING
Check the voltage. Do not connect the 12V inflator to a 24V battery.
WARNING
Do not leave the inflator running unattended. Overinflating an object could
result in serious injury.
**** THE INFLATOR CAN BE DAMAGED BY SAND, DUST OR WATER GETTING INSIDE THE INLET PORT. THIS WILL CAUSE OVERHEATING AND DAMAGE THE INTERNAL COMPONENTS. SHOULD THIS BE THE CASE, IMMEDIATELY SWITCH THE INFLATOR OFF.
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION
The inflator does not start| Battery LOW| Recharge the battery using the
110-240V battery charger or connect the device to an external battery via
power clamps
The ON button has not been pressed.| Press the ON button.
The safety fuse is blown or disconnected.| Insert or replace the fuse with one
of the same type (30 A)
The device is damaged| Contact a SCOPREGA service centre.
The inflator does not inflate| Hose wrong connection.| Connect the air hose to
the correct port (N3 on p.3).
Wrong pressure setting| Correct pressure setting.
Battery LOW with RED LED ON| Connect the device to an external battery via
cable and power clamps or recharge
the device.
11.1 ACCESSORY WARNING
The recommended accessories when using the inflator are the original SCOPREGA
ones.
The use of any accessory not recommended for this inflator can be dangerous.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>