SCOPREGA GE 22 GE3S0000 CAPRI Electric Inflator Instruction Manual
- June 12, 2024
- SCOPREGA
Table of Contents
SCOPREGA GE 22 GE3S0000 CAPRI Electric Inflator Instruction Manual
FOREWORD
Dear customer,
congratulations on choosing Scoprega.
We design and manufacture products of the highest quality to meet the needs of
our customers. Scoprega offers the highest quality in service as well. Our
specialised departments provide support and instructions when needed, as well
as comprehensive technical service.
We thank you for your trust.
WARNING
Read these instructions before using the inflator. Failure to follow all the instructions listed below may result in damage to the product and/or cause serious injury to persons.
PRELIMINARY WARNINGS
- Comply with all instructions in this document.
- Keep these instructions.
- Do not obstruct the air vents (items 3 and 5 PAGE 3).
- Always protect the power cable during recharging operations.
- Do not open the inflator. Refer all servicing to qualified service personnel authorised by Scoprega. Servicing is required when the device is damaged or not working in any way.
- Do not tamper with the product. Opening the inflator will void its warranty.
- Provide suitable ventilation.
- Avoid placing objects near the product during operation.
- Keep this product out of the reach of children.
- The operating inflator produces vibrations: therefore, we recommend you to use it on the floor, so as to avoid accidental falls.
**** DO NOT POWER THE CHARGER WITH A VOLTAGE HIGHER THAN 13V.
GENERAL SAFETY RULES
-
ALWAYS TAKE INTO ACCOUNT THE WORKING ENVIRONMENT.
Do not expose the inflator to rain. Do not use in the presence of flammable liquids or gases. -
A VOID UNINTENTIONAL STARTING.
Do not start the inflator with the inlet in contact with dust or water. -
PAY ATTENTION.
Pay attention to what you are doing. Use common sense. -
CHECK THAT THERE ARE NO DAMAGED PARTS.
Before using the inflator, carefully check its outer sides and components. -
DO NOT OPERATE portable inflators near flammable liquids or in gaseous or
explosive atmospheres. The inflator motors produce sparks that can release fumes. -
DO NOT INHALE!
The compressed air coming from the inflator is not clean. Never inhale air from your inflator. -
WARNING! RISK OF EXPLOSION.
Inflate the inflatable unit only complying with the manufacturer’s recommendations. Exceeding the pressure rating could cause the inflator to explode, resulting in personal injury. -
NEVER LEAVE THE DEVICE UNATTENDED.
Overinflation could result in serious injury and property damage. -
WARNING! RISK OF UNSAFE OPERATION.
Do not modify or attempt to repair the unit. Do not drill into or make any modifications to the inflator or its accessories. Any modification to the product will void its warranty. -
NEVER CARRY THE INFLATOR BY THE FLEXIBLE HOSE OR POWER CABLE.
BATTERY USE RULES
-
Before using the product, recharge completly the battery (duration 2 hours 80% charge).
-
For best performance, charge the battery when the ambient temperature is between 18°- 24°C (65°F – 75°F). DO NOT charge the battery with temperatures below +4.5°C (+40°F), or above +40.5°C (+105°F). This will prevent serious damage to the battery.
-
In case of prolonged period of inactivity of the inflator, it is recommended to fully recharge the battery at least once a month.
-
During charging, the charger may feel warm to the touch. This is a normal operating condition and does not indicate any malfunction.
-
DO NOT immerse the charger in water or other liquids.
KEEP THE CHARGER AWAY FROM ALL LIQUIDS. IT MAY CAUSE A SHORT CIRCUIT -
DO NOT try to charge the battery with any chargers other than those provided. The charger and battery are specifically designed to work together.
-
The charger is not intended for any use other than charging the inflator battery. Any other use may result in risk of fire, electric shock or short circuit.
-
Make sure that the cable is located so as it will not be stepped over, torn or damaged.
-
Do not operate the charger with a damaged cable or plug.
-
Do not disassemble the charger. Incorrect reassembly can result in a risk of electric shock, short circuit or fire.
-
Never use other chargers to charge this device. Always use original spare parts only.
-
Do not use the inflator while charging the battery
FUNCTIONAL DESCRIPTION
GE 22 CAPRI
- START & STOP BUTTONS
- PRESSURE REGULATING GAUGE WITH INDICATOR LIGHT
- INFLATION PORT
- INFLATION/DEFLATION HOSE
- DEFLATION PORT
- BATTERY CHARGER
- CHARGING PORT
INTRODUCTION
The GE 22 CAPRI is the result of a long research that aimed to add, inside an efficient and highly performing inflator for SUP. A further and fundamental feature for those who want to enjoy the best of an outdoor experience, namely: silence. Thanks to the completely innovative inflation system, the noise of this inflator has been reduced to less than 75 dB. Extraordinary result for an inflator that still reaches 1250 mbar with a capacity of 170 l / min. GE 22 CAPRI is supplied with a Lithium battery able to inflate 3 SUP boards of 265 liters at 1250 mbar, with one charge.
RECOMMENDED USES
Inflatables: SUP
TECHNICAL SPECIFICATIONS
ITEM| FLOW RATE (L / minute)| CHARGE VOLTAGE| MAX. PRESSURE
(mbar)| FUNCTIONS
---|---|---|---|---
GE 22 CAPRI| 170 l/m| 110/230 V| 1,25 bar (18,1 psi)| INFLATE/DEFLATE
INFLATING
ACCESSORIES AND POWER CABLES
- All accessories are located inside carry bag upper compartment: inflation hose, power cables and battery charger.
CONNECTIONS
- Connect the air hose to the port to inflate (item 3, pag. 3)
- Connect the inflator to the inflatable by using the air hose. (item 4, pag. 3)
TURNING ON THE INFLATOR
-
Set the desired pressure on the manometer (item 2, pag. 3).
-
Press START button. (punto 1, pag. 3)
The inflator will automatically stop when the set pressure is reached. -
Depending on the battery status, the manometer led will show three diffrent colors during the operations.
GREEN: chaged battery.
YELLOW: battery running low.
RED: battery low. -
When the manometer led is YELLOW, recharge the battery.
-
When the manometer led is RED the inflator will stop in a while. It is suggested to rechage the battery via supplied charger. (item 6, pag. 3).
TROUBLESHOOTING
PROBLEMA | POSSIBILE CAUSA | POSSIBILE SOLUZIONE |
---|---|---|
The inflator does not star | Battety low | Recharge the battery using the |
provided charge
The START button has not been pressed| Press the START button
The device is damaged| Contact a Scoprega service center.
The inflator does not inflate| Hose wrong connection| Connect the air hose to
the correct port ( Item 3, pag. 3).
Wrong pressure setting| Correct pressure setting
Battery low with RED led on| Connect the device to the provided battery
charger
ACCESSORY WARNING
The recommended accessories when using the inflator are the original SCOPREGA
ones.
The use of any accessory not recommended for this inflator can be dangeros.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>