SCOPREGA GE 1800 ROMA Electric Inflator Instruction Manual

June 12, 2024
SCOPREGA

SCOPREGA GE 1800 ROMA Electric Inflator

Product Information

  • Product Name: GE 1800 ROMA
  • Voltage: 230V – 120V
  • Model Numbers: K6131900 – K613910 –
  • Product Type: Electric Inflator

Product Usage Instructions

  1. Connect the inflation hose to the inflation nozzle of the GE 1800 ROMA and the main valve of the inflatable structure.
  2. Connect the fitting (highlighted in red in figure 2) to another valve of the inflatable structure using a PU (or PA) tube with a diameter of 6mm and a maximum length of 5m.
  3. Connect the power cable to the respective power outlet.
  4. Press the general switch of the inflator (Point 1 in Fig.1). The green light turning on indicates that the inflator is powered.
  5. If you need to change the pressure settings, refer to chapter 8 “Changing Pressure Settings”.
  6. Press the AUTO CYCLE button. The 2 LEDs will turn on and after 2 seconds, the GE 1800 ROMA will start inflating.
  7. To change the pressure settings, follow these steps:
    • a. Connect the power cable to the power outlet.
    • b. Turn on the green general switch.
    • c. Make sure AUTO CYCLE is turned off.
    • d. To adjust the pressure, follow the steps shown in figure 3.

Important Notes:

  • The pressure control hose and the 6mm adapter for the valve are not included.
  • Always make sure that the pressure control hose is connected to both the inflator and the inflatable structure.
  • In case of overheating due to prolonged use, the inflator will automatically shut off to prevent damage to its components.

Troubleshooting: Problem:
The inflator does not start.

  • Possible Causes: Power cable not connected to the power outlet, general switch is off.


  • Possible Solution: Connect the power cable to the power outlet, turn on the general switch.


Problem: The inflator stops working.


  • Possible Causes: Damaged power cable, power cable not connected to the power outlet, general switch is off, overheating.


  • Possible Solution: Check the power cable for any damages, connect the power cable to the power outlet, turn on the general switch, wait for the inflator to cool down before using it again.

FUNCTIONAL DESCRIPTION

SCOPREGA-GE-1800-ROMA-Electric-Inflator-01

GE 1800 ROMA

  1. MAIN SWITCH
  2. INFLATION PORT (IN)
  3. DEFLATION PORT (OUT)
  4. POWER CABLE
  5. PRESSURE DISPLAY AND SELECTOR
  6. PUSH-IN FITTING FOR PRESSURE CONTROL

SAVE THIS INSTRUCTIONS MANUAL FOR REFERENCE

FOREWORD
Dear customer, congratulations on choosing Scoprega.
We design and manufacture products of the highest quality to meet the needs of our customers. Scoprega offers the highest quality in service as well. Our specialized departments provide support and instructions when needed, as well as comprehensive technical service.

We thank you for your trust.

WARNING
Read these instructions before using the inflator. Failure to follow all the instructions listed below may result in damage to the product and/or cause serious injury to persons.

PRELIMINARY WARNINGS

  1. Comply with all instructions in this document.
  2. Keep these instructions.
  3. Always protect the power cable.
  4. Do not open the inflator. Refer all servicing to qualified service personnel authorized by Scoprega. Servicing is required when the device is damaged or not working in any way.
  5. Do not tamper with the product. Opening the inflator will void its warranty.
  6. Provide suitable ventilation.
  7. Avoid placing objects near the product during operation.
  8. Keep this product out of the reach of children.
  9. The operating inflator produces vibrations: therefore, we recommend you to use it on the floor, so as to avoid accidental falls.

DO NOT POWER THE INFLATOR WITH A VOLTAGE HIGHER THAN THE RATED ONE

GENERAL SAFETY RULES

  1. ALWAYS TAKE INTO ACCOUNT THE WORKING ENVIRONMENT.
    Do not use in the presence of flammable liquids or gases.

  2. AVOID UNINTENTIONAL STARTING.
    Do not start the inflator with the inlet in contact with dust or water.

  3. PAY ATTENTION.
    Pay attention to what you are doing. Use common sense.

  4. CHECK THAT THERE ARE NO DAMAGED PARTS.
    Before using the inflator, carefully check its outer sides and components.

  5. DO NOT OPERATE portable inflators near flammable liquids or in gaseous or explosive atmospheres. The inflator motors produce sparks that can release fumes.

  6. DO NOT INHALE!
    The compressed air coming from the inflator is not clean. Never inhale air from your inflator.

  7. WARNING! RISK OF EXPLOSION.
    Inflate the inflatable unit only complying with the manufacturer’s recommendations. Exceeding the pressure rating could cause the inflator to explode, resulting in personal injury.

  8. NEVER LEAVE THE DEVICE UNATTENDED.
    Overinflation could result in serious injury and property damage.

  9. WARNING! RISK OF UNSAFE OPERATION.
    Do not modify or attempt to repair the unit. Do not drill into or make any modifications to the inflator or its accessories. Any modification to the product will void its warranty.

  10. NEVER CARRY THE INFLATOR BY THE FLEXIBLE HOSE OR POWER CABLE.

  11. DO NOT OBSTRUCT THE SUCTION PORT

INTRODUCTION

The GE 1800 ROMA is a device capable of maintaining the nominal pressure in inflatable items within preset values (min. 50 mbar, max. 360 mbar), regardless of ambient temperature. The unit constantly monitors pressure variations within the item and regulates refilling and deflation in case of overpressure (A.R.S. Automatic Refilling System).

  1. The GE 1800 ROMA is a unit that is able to INFLATE and MAINTAIN an inflatable item at a preset pressure. THIS MEANS THAT THE INFLATABLE ITEM MUST ALWAYS BE CONNECTED TO THE INFLATOR.

  2. THE INFLATOR IS DELIVERED WITH A FACTORY PRE-SET PRESSURE. TO CHANGE THIS SETTING PLEASE READ THE INSTRUCTIONS CAREFULLY (CHAPTER 8). IN CASE OF DOUBT, PLEASE CONTACT THE SCOPREGA SERVICE DEPARTMENT.
    WARNING: THE PRESSURE CONTROL HOSE AND THE 6 MM VALVE ADAPTOR ARE NOT INCLUDED!

  3. THE INFLATOR IS EQUIPPED WITH A THERMAL OVERLOAD CUTOUT THAT INTERRUPTS THE INFLATING OPERATIONS IN CASE OF MOTOR OVERHEATING. NORMAL OPERATION WILL CONTINUE AUTOMATICALLY AFTER A 20/40-MINUTE PAUSE.

  4. THE INFLATOR IS SUPPLIED WITHOUT HOSES OR FITTINGS. HOSES AND FITTINGS SUITABLE
    FOR THIS INFLATOR FOR CONNECTING TO THE MOST COMMON INFLATION VALVES CAN BE PURCHASED FROM AUTHORISED SCOPREGA CENTRES.

TECHNICAL SPECIFICATIONS

  1. Power supply 210-240 Vac; 50 Hz or 110-130 Vac, 60 Hz
  2. MAX. power 1800 W
  3. MAX. pressure 360 mbar (5.2 psi)
  4. MIN. pressure 50 mbar (0.7 psi)
  5. Filling pressure tolerance adjustable from 30 to 70 mbar
  6. MAX. flow rate 2700 l/min
  7. Dimensions 330 x280 x h 350 mm
  8. Weight 6.4 kg
  9. Operating temperature range -10/40°C
  10. Protection degree IP 66

HOW TO USE

  1. Connect the inflation hose to the inflation port of the GE 1800 ROMA and to the main valve of the inflatable item.

  2. Connect the fitting (circled in red in figure 2) to another valve of the inflatable item using a PU (or PA) hose with a diameter of 6 mm and a maximum length of 5 m.
    WARNING: CHECK THAT THE PRESSURE CONTROL HOSE IS ALWAYS CONNECTED TO THE INFLATOR AND TO THE INFLATABLE ITEM

  3. Connect the power cable to the appropriate socket.

  4. Press the main switch of the inflator (Point 1 Fig.1). When the green light comes on, the inflator is ready to work.

  5. Press the ON/OFF switch.

  6. The display will show the preset pressure that the inflatable item must reach. If it needs to be changed, refer to chapter 8 “HOW TO CHANGE THE PRESSURE SETTINGS”. 7. Press the AUTO CYCLE button. The 2 LEDs light up and after 2 seconds the GE 1800 ROMA will start to inflate.

SCOPREGA-GE-1800-ROMA-Electric-Inflator-02

HOW TO CHANGE THE PRESSURE SETTINGS

  1. CONNECT THE POWER CABLE TO THE SOCKET.
  2. TURN ON THE MAIN GREEN SWITCH
  3. ENSURE THAT THE AUTOCYCLE IS SWITCHED OFF
  4. FOLLOW THE STEPS BELOW TO ADJUST THE PRESSURE:
  • A. PRESS MODE to select the unit of measurement (mbar, psi, kPa, bar): press the MODE button multiple times, until you find the desired unit.

  • B. Changing the inflation pressure using the SET+/ SET- buttons: when a button is pressed for 2 seconds, the display starts blinking and the pressure can be adjusted by pressing the SET+/SET- buttons. After 2 seconds, the display stops blinking and the pressure is memorized. The pressure can be set between 50 and 360 mbar.
    SCOPREGA-GE-1800-ROMA-Electric-Inflator-04

  • C. Changing the filling pressure: when the MIN button is pressed for 3 seconds, the display starts blinking. The value may be changed by using SET+ and SET-. After 2 seconds, the display stops blinking and the value is memorized. The filling pressure may be adjusted from 30 to 70 mbar with respect to the operating pressure. Example: if you wish to reach an inflation pressure of 250 mbar and the refilling value is set to 50 mbar, when the pressure of the inflatable item reaches 200 mbar, the GE 1800 ROMA switches back on and the ARS system brings the pressure of the inflatable item to 250 mbar.

  • D. Changing the deflation pressure: when the MAX button is pressed for 3 seconds, the display starts blinking. The value may be changed by using SET+ and SET-. After 2 seconds, the display stops blinking and the value is memorized. The deflation pressure may be adjusted from 30 to 70 mbar with respect to the operating pressure.
    Example: if you wish to reach an inflation pressure of 250 mbar and the deflation value is set to 50 mbar, when the item reaches 300 mbar, the ARS system opens the deflation valve until it reaches 250 mbar.

  • E. After the changes press AUTO CYCLE: The 2 LEDs light up after 2 seconds and the red LED turns off; the green LED indicates that the GE 1800 ROMA will automatically start to inflate/deflate and refill to the pressure. With the automatic cycle activated (LEDs on), the unit automatically checks the pressure of the inflatable item.

WARNING
IN THE EVENT OF A POWER FAILURE DURING OPERATION, THE DEVICE IS NOT ABLE TO KEEP THE WORKING SETTINGS STORED AND CANNOT RESTART AUTOMATICALLY WHEN POWER IS RESTORED.

PER SGONFIARE

  1. Remove the cover opposite the deflation port by unscrewing the appropriate knobs (point 3 – fig 1)
  2. Connect the hose to the inflator’s Inlet port (point 3 – fig 1)
  3. Connect the hose to the valve of the inflatable unit. It is important to choose the correct fitting for the valve and check that there are no air leaks. Ensure that there are no bottlenecks, obstructions or leaks in the air path.
  4. Switch on the inflator by selecting ON on the main power switch (Point 1, Figure 1).
  5. Start deflation by pressing the ON/OFF button on the display (Point 5, Figure 1).
  6. Switch off the inflator once deflation is complete by turning the main switch to OFF.
    N.B. The inflator does not stop automatically.

ATTENTION, IN THE EVENT OF OVERHEATING DUE TO PROLONGED USE, THE INFLATOR WILL AUTOMATICALLY STOP TO PREVENT DAMAGE TO ITS COMPONENTS.

THE INFLATOR DOES NOT TURN OFF AUTOMATICALLY. SWITCH OFF THE INFLATOR ONCE THE INFLATABLE HAS BEEN COMPLETELY EMPTIED OF AIR.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION
The inflator does not start The power cable is not connected to the socket

Connect it correctly
The main GREEN switch is off| Press the switch
The power cable is damaged| Ask the SCOPREGA service to replace or repair the cable
The inflator is stopped| The power cable is not connected to the socket| Connect it correctly
The main switch is off| Press the switch
Over-temperature| Wait until the ARS motors cool down. The inflator will restart automatically.
The inflator does not stop| The pressure sensor hose (blue) is not properly connected to the pump or valve of the inflatable item| Connect the hose correctly
The ARS system is not working/ The pressure measured on the display does not change| The pressure sensor hose (blue) is not properly connected to the pump or valve of the inflatable item| Connect the hose correctly

ACCESSORY WARNING
The recommended accessories when using the inflator are the original SCOPREGA ones.
The use of any accessory not recommended for this inflator can be dangerous.