SCOPREGA GM 6 K6120770 Hand Pump Instruction Manual

June 9, 2024
SCOPREGA

GM 6 K6120770 Hand Pump
Instruction ManualSCOPREGA GM 6 K6120770 Hand
Pump

GM 6 K6120770 Hand Pump

SAVE THIS INSTRUCTIONS MANUAL FOR REFERENCE![SCOPREGA GM 6 K6120770 Hand Pump

PRELIMINARY WARNINGS

WARNING
Read these instructions before using the hand pump.
Failure to follow these instructions may damage the product or cause serious injury to persons.
WARNING

  1. Do not disassemble the pump. Incorrect reassembly may impair its functionality
  2. Keep the pump or its parts away from fire. Check local regulations for disposal of the pump.
  3. Keep the device out of the reach of children.

WARNING
Risk of explosion. Inflate to the pressure recommended by the manufacturer.
An excessive pressure can cause a burst dangerous to people.

FOREWORD

Dear customer, congratulations on choosing Scoprega.
We design and manufacture products of the highest quality to meet the needs of our customers. Scoprega offers the highest quality in service as well. Our specialised departments provide support and instructions when needed, as well as comprehensive technical service.
We thank you for your trust.
WARNING
Read these instructions before using the inflator. Failure to follow all the instructions listed below may result in damage to the product and/or cause serious injury to persons.

GENERAL SAFETY RULES

  1. ALWAYS TAKE INTO ACCOUNT THE WORKING ENVIRONMENT. Do not expose the pump to rain. Do not use in the presence of flammable liquids or gases.
  2. Do not use the pump with the inlet in contact with dust or water.
  3. BE CAREFUL. Care must always be taken. Use common sense.
  4. DO NOT INHALE! The compressed air coming from the pump is not clean Never inhale air from the pump or from a breathing device connected to the pump.
  5. Never handle the pump using the hose.

INTRODUCTION

GM 6 is a new generation of hand pumps for all types of inflatable products. Its unique design ensures high efficiency and ease of use.
Its main features are:

  • Manual double/single flow switching, to minimise inflation effort
  • Ergonomic handle with built-in air filter
  • Inflation port on the pump body (anti-twisting hose)
  • Built-in pressure gauge

FEATURES

ITEM CODE CAPACITY MATERIAL MAX. PRESSURE(mbar) FUNCTIONS
GM 6 K6120770 Approx. 2X2.5 litres ABS + Aluminium 1.0 bar (14.5 psi)

INFLATION/DEFLATION

INSTRUCTIONS FOR USE

TO INFLATE

  • The pump is equipped with standard nozzles available in the package.
  • Connect the hose on the front side of the pump (Fig. 1 page 3) and make sure that “Mode” lever on the rear side of the pump (Fig. 3 page 3) is in vertical position.
  • Connect the pump to the inflatable product.
  • Start pumping. When the strain increases, turn the “Mode” lever (Single flow) on the rear side of the inflation port 90° counter-clockwise (Fig. 3 page 3).
  • Continue pumping until reaching the desired pressure.

TO DEFLATE

  • Connect the hose to the handle port (Fig. 2 page 3) and make sure that “Mode” lever on the rear side of the pump (Fig. 3 page 3) is in vertical position.
  • Connect the pump to the inflatable product.
  • Continue pumping until the inflatable product is empty.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION

The pump does
not inflate| Hose improperly connected.| Connect the hose to the correct port.
Internal seals or valves damaged| Contact a SCOPREGA service centre.

The recommended accessories when using the inflator are the original SCOPREGA ones.
The use of any accessory not recommended for this inflator can be dangerous.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals