SCOPREGA GE20-2 Electric Inflator Instruction Manual

June 11, 2024
SCOPREGA

GE20-2 Electric Inflator

SCOPREGA-GE20-2-Electric-Inflator-product-image

Product Information

The GE20-2 K6130702 is an electric inflator that can be used for inflating objects such as SUP, small boats, kayaks, kites, rafts, air mattresses, pool inflatables, etc. It has a maximum pressure fuse of 30 A and can inflate up to 125 L/minute. The inflator comes with a pressure gauge that has an automatic shut-off function and connectors for inflating all common valves. The product dimensions are 220x320x220 mm, and it comes with a 110-240V transformer, a cable with power clamps for 12V power supply, and a cable with a 12V cigarette lighter socket.

Product Usage Instructions

  1. Before using the inflator, read and understand all the safety instructions provided in the manual.
  2. This inflator is only for inflating objects and not for deflating them.
  3. Connect the inflator to a power source using the appropriate cable.
  4. Attach the air hose to the outlet nozzle of the inflator.
  5. Attach the appropriate adapter to the air hose for inflating the desired object.
  6. Turn on the inflator using the On/Off button.
  7. Set the desired pressure using the pressure gauge and wait for the inflator to automatically shut off when the desired pressure is reached.
  8. If the LED on the pressure gauge turns yellow, turn off the inflator and connect it to a 12V power supply using the cable with power clamps or an external battery.
  9. If the LED on the pressure gauge turns red, turn off the inflator and connect it to an external battery using the cable with power clamps.
  10. When finished, turn off the inflator and disconnect it from the power source.
  11. In case of any problems, refer to the troubleshooting section of the manual.

FUNCTIONAL DESCRIPTION

SCOPREGA-GE20-2-Electric-Inflator-01

GE 20-2

  1. ON – OFF BUTTONS
  2. PRESSURE SETTING GAUGE WITH LIGHT INDICATOR
  3. OUTLET (INFLATE) PORT
  4. AIR HOSE WITH ADAPTERS
  5. INLET PORT / AIR VENT
  6. 110-240V ADAPTER
  7. CABLE WITH 12V POWER CLAMPS
  8. CABLE WITH 12V CIGARETTE LIGHTER SOCKET

WARNING
This inflator is not to be used for deflating operations.

SAVE THIS INSTRUCTIONS MANUAL FOR REFERENCE

FOREWORD

Dear customer,
congratulations on choosing Scoprega.
We design and manufacture products of the highest quality to meet the needs of our customers. Scoprega offers the highest quality in service as well. Our specialised departments provide support and instructions when needed, as well as comprehensive technical service.

WARNING
Read these instructions before using the inflator. Failure to follow all the instructions listed below may result in damage to the product and/or cause serious injury to persons.

PRELIMINARY WARNINGS

  1. Comply with all instructions in this document.
  2. Keep these instructions.
  3. Do not block the air vents (No.5 ).
  4. Always protect the power cable.
  5. Do not open the inflator. Refer all servicing to qualified service personnel authorized by Scoprega. Servicing is required when the device is damaged or not working in any way.
  6. Do not tamper with the product. Opening the inflator will void its warranty.
  7. Provide suitable ventilation
  8. Avoid placing objects near the product during operation.
  9. Keep this product out of the reach of children.
  10. The operating inflator produces vibrations: therefore, we recommend you to use it on the floor, so as to avoid accidental falls.

NOTE This inflator is not to be used for deflating operations.

DO NOT POWER THE INFLATOR WITH A VOLTAGE HIGHER THAN THE RATED ONE.

GENERAL SAFETY RULES

  1. ALWAYS TAKE INTO ACCOUNT THE WORKING ENVIRONMENT.
    Do not expose the inflator to rain. Do not use in the presence of flammable liquids or gases.

  2. AVOID UNINTENTIONAL STARTING.
    Do not start the inflator with the inlet in contact with dust or water.

  3. PAY ATTENTION.
    Pay attention to what you are doing. Use common sense..

  4. CHECK THAT THERE ARE NO DAMAGED PARTS.
    Before using the inflator, carefully check its outer sides and components.

  5. DO NOT OPERATE
    portable inflators near flammable liquids or in gaseous or explosive atmospheres. The inflator motors produce sparks that can release fumes.

  6. DO NOT INHALE!
    The compressed air coming from the inflator is not clean. Never inhale air from your inflator.

  7. WARNING! RISK OF EXPLOSION.
    Inflate the unit only complying with the manufacturer’s recommendations. Exceeding the pressure rating could cause the inflator to explode, resulting in personal injury.

  8. NEVER LEAVE THE DEVICE UNATTENDED.
    Over inflation could result in serious injury and property damage.

  9. WARNING! RISK OF UNSAFE OPERATION
    Do not modify or attempt to repair the unit. Do not drill into or make any modifications to the inflator or its accessories. Any modification to the product will void its warranty.

  10. Never carry the inflator by the flexible hose or power cable.

BATTERY USE RULES

  1. To operate the inflator for the first time, insert the fuse located inside the carry bag.

  2. Perform a complete battery charge cycle (lasting 8 hours).

  3. For best performance, charge the battery when the ambient temperature is between 18°- 24°C (65°F – 75°F). DO NOT charge the battery with temperatures below +4.5°C (+40°F), or above +40.5°C (+105°F). This will prevent serious damage to the battery.

  4. The charger and battery may become warm to touch while charging. This is a normal condition, and does not indicate a problem.

  5. DO NOT immerse the charger in water or any other liquids.
    KEEP THE CHARGER AWAY FROM ALL LIQUIDS. IT MAY CAUSE A SHORT CIRCUIT

  6. DO NOT try to charge the battery with any chargers other than those provided. The charger and battery are specifically designed to work together.

  7. The charger is not intended for any use other than charging the inflator battery. Any other use may result in risk of fire, electric shock or short circuit.

  8. Make sure that the cable is located so as it will not be stepped over, torn or damaged.

  9. Do not operate the charger with a damaged cable or plug.

  10. Do not operate the charger if it has received a sharp blow, been dropped or damaged in any way.

  11. Do not disassemble the charger. Incorrect reassembly can result in a risk of electric shock, short circuit or fire.

  12. Never use other chargers to charge this device. Always use original spare parts only.

INTRODUCTION

The GE 20-2 is a next-generation high-efficiency portable electric inflator, which stands for reliability and functionality. The GE 20-2 is equipped with a double-piston pumping unit that allows any object to be inflated to a pressure between 10 and 1,500 mbar. The inflator starts when the ON button is pressed and automatically stops when the set pressure in the pressure gauge is reached. The device stops when the user presses the OFF button.
The GE 20-2 is fully portable as the battery is integrated in the device. When the battery is low (red light on the pressure gauge), the inflator can be connected to a cigarette lighter socket or to an external 12V battery via the power clamps. The battery can also be charged by a 12V cigarette lighter socket or 110-240 AC/DC adapters.
The inlet port is protected by a multilayer filter, the outlet port is equipped with a check valve.
The unit is protected against overheating. In the event of high outside temperature or overuse, the inflator will automatically stop and a red LED on the pressure gauge will indicate its status. The device can be restarted when the red LED goes OFF.

RECOMMENDED USES
Inflatable items, such as: SUPs / Small rubber dinghies (3/4 m) / Kayak / Kites / Rafts / Air mattresses / Swimming pool floats / etc.

TECHNICAL SPECIFICATIONS

ITEM| FLOW RATE

(L / minute)

| SAFETY FUSE| MAX. PRESSURE

(mbar)

| FUNCTIONS
---|---|---|---|---
GE 20-2| 125| 30 A| 1,500 (22 PSI)| INFLATION

  • PRESSURE SETTINGS: PRESSURE GAUGE WITH AUTOMATIC SWITCHING OFF
  • INFLATION FITTINGS: AVAILABLE FOR MOST COMMON VALVES
  • CARRY BAG DIMENSIONS: 220x320x220 mm

USE FOR INFLATING

ACCESSORIES AND POWER CABLES
1. All accessories are located inside carry bag upper compartment: inflation hose, power cables, and battery charger.

CONNECTING THE ACCESSORIES

  1. The inflator is supplied with standard conical adapters that are located inside carry bag upper compartment.
  2. Make sure that the OFF button has been pressed.
  3. Take the hose from the carry bag.
  4. Connect the air hose to the port to inflate (OUT).
  5. Assemble the most suitable adapter for the inflator.

TURNING ON THE INFLATOR

  1. To INFLATE, connect the hose to the outlet port (N3 fig. on p.3).

  2. Set the desired pressure on the pressure switch (N2 fig. on p.3).
    The inflator will automatically stop when the set pressure is reached.

  3. The device starts when the ON button is pressed. Depending on the battery level, the pressure gauge LED will show three different colors:
    GREEN: charged battery.
    YELLOW: battery running low.
    RED: battery low.
    When the LED is not GREEN, we recommend you to recharge before operating. Otherwise, the inflator can be used by connecting it to a car cigarette lighter socket (N8 on p.3) or to an external battery via a cable with power clamps (N7 on p.3).
    NOTE The inflator battery will not be charged when using the cigarette lighter cable or the power terminal cable.

  4. If the LED on the pressure gauge turns YELLOW, press the OFF button and connect the inflator to a car cigarette lighter socket or an external battery via cable and power clamps.

  5. If the LED on the pressure gauge turns RED, press the OFF button and connect the inflator to an external battery via cable and power clamps.

WARNING

  • Make sure polarity is correct (red terminal to positive). Otherwise the inflator WILL NOT START.
  • Be careful when connecting the cable to the battery, in order not to short the battery with conducting materials such as rings, bracelets and keys. The battery or adapter may overheat and cause injury.
  • Check the voltage. Do not connect the 12V inflator to a 24V battery.
  • Do not leave the inflator running unattended. Overinflating an object could result in serious injury.

THE INFLATOR CAN BE DAMAGED BY SAND, DUST OR WATER GETTING INSIDE THE INLET PORT. THIS WILL CAUSE OVERHEATING AND DAMAGE THE INTERNAL COMPONENTS. SHOULD THIS BE THE CASE, IMMEDIATELY SWITCH THE INFLATOR OFF.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION
The inflator does not start Battery LOW Recharge the battery using the

110-240V battery charger or connect the device to an external battery via power clamps
The ON button has not been pressed.| Press the ON button.
The safety fuse is blown or disconnected.| Insert or replace the fuse with one of the same type (30 A)
The device is damaged| Contact a SCOPREGA service centre.
The inflator does not inflate| Hose wrong connection.| Connect the air hose to the correct port (N3 on p.3).
Wrong pressure setting| Correct pressure setting.
Battery LOW with RED LED ON|

Connect the device to an external battery via cable and power clamps or recharge the device.

ACCESSORY WARNING
The recommended accessories when using the inflator are the original SCOPREGA ones.
The use of any accessory not recommended for this inflator can be dangerous.