Sinocare BA-823 Blood Pressure Monitor Instruction Manual
- June 5, 2024
- Sinocare
Table of Contents
- Important Notes
- Measurement Accuracy
- Helpful Information
- Correct Method of Measurement
- Parts Identification
- Description of Display Marks
- Preparation Before Taking a Measurement
- Taking a Measurement
- Setting Date and Time
- Memory Funetion
- Er Indicators and Troubleshooting
- Troubleshooting
- Sensor Calibration Mode
- Care and Maintenance
- Specifications
- Blood Pressure Log
- Documents / Resources
Automatic Upper Arm Blood Pressure Monitor
Ageless Health Industrial Co., Ltd
Ageless Health Industrial Co., Ltd The 3rd-floor unit Factory Al , Dongsheng
Sima Industrial Area, NO.33 sherbet Road, Sima Village, Changping Town,
Dongguan City, Guangdong Province, P. R. China
**EC REP**
MedNet GmbH Borkstrasse 10 , 48163 Muenster , Germany
Period Of Use:2 years
Important Notes
-
Only a physician is qualified to interpret changes in your blood pressure.
This device is not intended to replace regular medical examinations. It is recommended that your physician review your procedure for using this monitor. Never make adjustments to your medication unless it is the advice of a physician. -
This Blood Pressure Monitor is intended for use by adults,Children should not use this monitor unless it is under the supervision of an adult.
-
Don’t instead other vendors cuff, Since these will affect Measurement accuracy.
-
Please read the entire instructions carefully before using this Blood Pressure Monitor.
-
To use an external adapter, Please use a DC 5V/1A power adapter that meets the medical safety standard.
-
****Warning Symbol
-
[Type B Symbol
-
Class II Symbol
Measurement Accuracy
The quality of the device has been verified and conforms to the provisions of
the EC council directive 93/42/EEC on medical devices as well as the EMC
directive 89/336/EEC:
EN 1060-1
Non-invasive blood pressure measuring equipment General requirements
EN 1060-3
Non-invasive blood pressure measuring equipment Supplementary requirements for
electro-mechanical blood pressure measuring systems
EN 60601-1
Safety requirements for medical electrical equipment
EN 60601-1-2
Electromagnetic compatibility and safety for medical electrical equipment
EN 14971
Risk analysis for medical devices
Helpful Information
What is Blood Pressure?
Blood Pressure is the force that blood exerts on the arteries, This force is
constantly changing as the heart beats. When the heart contracts,blood
pressure reaches its highest value. This is called systolic blood pressure.
When the heart relaxes between beats,the value of blood pressure is lower.
This is called the diastolic blood pressure. The device of measure for blood
pressure is the millimeter of mercury, abbreviated mmHg.
For example, an individual’s blood pressure may be measured as 120 mmtg(
systolic) and 80 mmHg (diastolic), This would be spoken as 120 over 80″ and
written as “120/80.
Remember that blood pressure varies throughout the day. Food intakes, smoking,
time of day, stress, level of exercise and many other factors can affect it,
Typical daily blood pressusre fluctuations
(Example:35-year-old male)
What is High Blood Pressure?
Hypertension, or high blood pressure,is a condition where an individual’s
blood pressure remains high over a long period of time. Untreated,
Hypertension can cause many serious medical problems including strokes and
heart attacks. To control hypertension, the American Heart Association
recommends that you not smoke, reduce fat and salt intake, maintain proper
weight, exercise and get regular physical check-ups.
Blood Pressure Classification
The world health Organisation (wHO) and the international Society of
Hypertension
(ISH),evaluation.
Why is it Important to Measure Your Blood Pressure at Home?
Having your blood pressure taken at the doctor’s office may cause you to
become nervous, thus artificially raising your reading.Having the ability to
take your blood pressure at home makes it easy to record a log of your daily
readings. This will help you gain a greater understanding of your blood
pressure reading and the factors that affect it. Be sure that you share your
information with your physician.
Hints for Accurate Measurement
-
Relax and try to remain still for 5 to 10 minutes before a measurement.
-
Remove any clothing on the upper arm so that the cuff can be placed directly on the skin.Constriction of the upper arm caused by rolling up a shirt sleeve may cause an inaccurate reading Avoid this condition by completely removing the garment causing the constriction.
-
Refrain from eating, smoking, and drinking (especially alcoholic beverages) before a measurement sine these activities can affect your blood pressure.
-
Remember that blood pressure varies continuously throughout the day.
Try to take your blood pressure at the same time each day. -
Do not be concerned with the results of one measurement. Many measurements, recorded over a long period of time, will provide a better indication of your blood pressure.
-
Please relax for S to 10 minutes before taking another measurement.
-
Many factors can affect your blood pressure such as exercising, eating, talking, moving, nervousness, environment and temperature changes, emotional stress can cause an increase in blood pressure Daily fluctuations of 25 to 50 mmHg are common.
Please note;
Some individuals with hypertension, diabetes, kidney disorders,
arteriosclerosis or poor circulation may see a significant difference in blood
pressure readings taken from the wrist as compared to readings from the upper
arm.It is recommended that you consult with your physician concerning the use
of this monitor.
Correct Method of Measurement
To obtain the most accurate blood pressure measurement, please follow these important directions.
- Be seated in a chair with back support.
- Rest your arm on a table so the cuff is at the same level as your heart.
- Place both feet on the ground
IMPORTANT:
The arm cuff must be at the same level as your heart, or accurate measurement
will not possible.(Your heart is located slightly below your left armpit.)
Parts Identification
Description of Display Marks
| Inflating
---|---
| Deflating
| Measurement Error
| Measuring
| Battery Display
battery indicator will reduce when power redue
Plese replace with new batteries when the battery indicator flashes
| Arrhythmia detection Function
Preparation Before Taking a Measurement
Battery Installation / Replacement
- slide the battery cover off in the direction of the arrow.
- Install or replace the four alkaline”AA”batteries, noting the proper orientation of positive(+) and negative (-) terminals of the batteries in the battery compartment.
- Replace the battery cover.
- If the Low Battery Symbol appears on the display, replace all batteries with new ones.
- Remove the batteries if the device will not be used for an extended period of time.
Note
Batteries are hazardous waste.Do not dispose them together with the household
garbage.
How to Apply the Arm Cuff
(Preferably the left arm.)
-
Insert the end of the cuff through the D-Ring to make a loop.(Make sure that the Velcro stays outside when it is done.)
-
Ware the arm cuff with the hose downward.
Pull the end of the cuff and secure it snugly with the velcro. -
Adjust the cuff that the bottom edge is about 1 inch above the elbow on the inside of the left arm. Please mind the colored area on the cuff covers the brachia artery.
-
Plug in the air tube connector to the monitor.
Taking a Measurement
Please read the previous section on proper placement of the cuff and proper arm position.
-
After the cuff has been properly placed on the arm, please press Set button and select on the up left-hand corner of the LCD screen, and then press the Start/ Stop button.
-
After the display reads “00”, the cuff will automatically inflate to an appropriate pressure. After the inflation, it slowly deflates to take the measurement. When the heart mark” “appears which indicates the measurement is in process. The cuff will be quite snug for a short while, this is normal. Try to remain relaxed, refrain from talking, and be as still as possible during the measurement.
Note: If the device determined that the initial inflation pressure was insufficient, it will re-inflate to a higher pressure. -
The device will completely deflate when the measurement is finished. The systolic and diastolic pressure and pulse rate will be displayed.
To end measurement for any reason, just press Start/stop button to turn off
the unit and release the cuff pressure.
If during a measurement the power drops to an insufficient level, the device
will end the measurement and display the low battery symbol. Please replace
the batteries and repeat the measurement.
If the device can not detect your pulse, it will end the measurement attempt.
Please wait a few minutes make sure that the cuff is positioned properly, and
try again.
The device will automatically shut off 1 minute after a measurement finished.
You can also press Start/ Stop button to shut the device off.
Setting Date and Time
- The device with time and date displayed on the LCD, please set them per the following method.
- Long press the SET button for 3-5 seconds, and the individual figure will start blinking sequentially from month, date, hour to the minute.
Note: Press the Memory button once will cause the display to advance by one digit.
Memory Funetion
Memory input
When a valid measurement is made, the result (systolic, diastolic, pulse rate,
date and time) will be stored in the memory automatically as soon as the
device is turned off or when another measurement is initiated. The device is
capable to store 2×90 readings, and also compute the average of the latest 3
readings. When readings stored more than 90, the oldest ones will be replaced.
Memory recall
By pressing Memory button, AVG will be shown in the down left hand corner,
which means you entered into memory function. AVG means the average of all
recorded readings. Now press the Memory button again, 01 will be shown in he
down right-hand corner, which is your latest reading in the memory, when you
press it again, 02 will be shown which is the one before the latest reading.
When you press the button repeatedly, the records will be displayed
sequentially.
Memory erase
Press memory button and hold it down more than 3 seconds, you will erase the
records of readings of the selected memory group.
Er Indicators and Troubleshooting
Error indicators
Error indicators
| Possible sources of errors
---|---
| Indication: Correction:| Incomplete inflation
Check the cuff has been connected with device firmly, if same Er message
indicated, request a repair
| Indication: Correction:| cuff over inflated and release automatically
Take a break, and reposition the cuff and measure again
| Indication: Correction:| Could not obtain the pulse rate Reposition the cuff
and measure again
| Indication: Correction:| Strong Electromagnetic interference (Mobile phone
and computer: Relax and take a break, and then measure again.
| Indication: Correction:| irregular pulse rate or blood pressure, Relax and
take a break, and then measure again.
Troubleshooting
Problem | Recommended method |
---|---|
No display | Make sure that the batteries are installed in the proper |
direction. (Polarity matches to the indication in the battery case.)
No measurement occurs| Check that the cuff is positioned properly, pgo over
the measurement procedure again.
Blood pressure readings are too high or too low| Check if the arm is
positioned properly
Position your arm on a table, so the cuff is at the same level as your heart
Remain seated during the entire measurement period
Refrain from hand and body movements during measurement
Blood pressure reading are vaiable| Your blood pressure can fluctuate
considerably throughout the day, all of the following factors can influence
your blood pressure Emotional state Daily activities or exercise Smoking
Drinking alcoholic beverages Eating
Taking certain medications
Sensor Calibration Mode
The blood pressure device should be calibrated by the qualified company.
And you can send back to our company for calibration.
mmHg and kPa transferring instruction
when the device powered on and finished a measurement, the systolic and
diastolic pressure will be displayed, which unit is mmHg; if you want to
change the measurement unit, you can press Start/ Stop button for 10 seconds
when the device powered off, and then press ” Memory” button select mmHg or
KPa.
Care and Maintenance
- Keep the device away from high temperatures or high humidity, and direct sunlight.
- Keep sharp objects away from the cuff.
- Do not press the Start/Stop button without the cuff around your arm to avoid excess pressure build up that may damage the cuff.
- Use the device at a sufficient distance from devices with strong electrical fields, such as television, microwave ovens, X-ray equipment, etc.
- Do not subject the device to strong impacts or drop it onthe floor.
- Do not disassemble or modify the device or the cuff.
- Remove the batteries when the device is to be stored for extended periods of time.
Note:
Removing the batteries will erase all readings in memory.
- Use only a soft dry cloth to clean the unit. Do not use solvents or other petroleum-based cleaners .
- Circuit diagram and repairable part can be provided if it’s necessary.
Specifications
Model: | BA-823 |
---|---|
Measuring method: | Oscillometric |
Memory function: | Storage and recall 90×2 measurements with average |
Display: | Digital LCD |
Measuring range: | Pressure: 0-280 mmHg Pulse: 40-199/minute |
Sensor accuracy: | Pressure:±3 mmHg |
Pulse:: ±5%
Inflation system:| Electro-pneumatic pump
Arm size ranges:| 22-42 cm(8.6-16.5 inches)
Batteries:| 1.SV alkaline (LR6/AA)X4
Automatic power-off:| Approx. 1 minute after measurement
Reference method for clinical trials:| Auscultatory measurement
Weight:| Approx. 430g(without batteries)
Operating condition:| +5C+40C 10%90%RH
Storage and transport condition:| -20C+65C 10%95%RH
Standard cited:| EN 1060-1 EN 60601-1-2 EN 1060-3
EN 14971 EN 60601-1 YY-0670
Blood Pressure Log
MANUFACTURER
Ageless Health Industrial Co .,LTD
The 3rd floor unit Factory A1 ,Dongsheng Sima Industrial Area,N0.33 sherbet
Road,
Sima Village, Changping Town,Dongguan City, Guangdong Province, P. R.
China
Documents / Resources
|
Sinocare BA-823 Blood Pressure
Monitor
[pdf] Instruction Manual
BA-823 Blood Pressure Monitor, BA-823, Blood Pressure Monitor
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>