Westinghouse WH10P NCCO Air Treatment Unit Instruction Manual

June 12, 2024
Westinghouse

WH10P NCCO Air Treatment Unit Instruction Manual
Westinghouse WH10P NCCO Air Treatment Unit

Safety Instructions

  • Before using the appliance, please read the safety and operation instructions carefully and thoroughly.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
  • If the power cord is damaged, it must be replaced by either the manufacturer, a service agent, or a qualified service professional.
  • Prior to cleaning or maintaining, the appliance must be unplugged and disconnected from its power source
  • In order to avoid injury, safety instructions must be followed. The below symbols classify the risk or degree of injury that may occur as the result of incorrect operation.

WARNING
This symbol indicates ‘if not follow the warning, it would cause injury or death.’

**PRECAUTION**
This symbol indicates‘if not follow the precaution, it would cause injury or property loss.’

PROHIBITION

MANDATORY

  • Do not move the unit by pulling on the power cord.

    • (Otherwise the power cord could be damaged, resulting in fire or electric shock.)
  • **** Do not damage the power line or the plug.

    •  Do not cut, refitting, over twisting, extruding power line. Do not put the power line near to any heatsources, do not put any heavy objects over the power line. (Otherwise the power line could be damaged, resulting in fire or electric shock. )
  • Do not use power source other than DC�V �A.

    • (Otherwise the power line would overheated, resulting in fire.)
  • Do not put fingers, metal, or any other objects into air inlet / outlet or gap.

    •  (Otherwise it could result in electric shock or injury.)
  • Do not touch power plug with wet hand.

    • (Otherwise it could result in electric shock.)
  • Do not place the unit in a location near a water / liquid source or where it caneasily get wet.

    •  (Otherwise, the unit may be short-circuited, and resulting in fire or electric shock.)
  • It is prohibited to place small objects near any area of the unit where a child or infant might be liable to touch.

    • (If the child or infant eat these small objects by mistake, please immediately take the child or infant to hospital.)
  •  It is prohibited to place the battery in the fire or near heat.

    •  (Damage to the battery outer insulation cover or release valve could cause personal injury.

WARNING

  •  Do not disassemble, repair, or modify the unit on your own.
    • (Otherwise it could result in fire or electric shock. If maintenance work is needed, please contact Customer Service Centre or the distributor.)

**WARNING**

When any of the following situations occur, please stop operating the unit and disconnect the power supply immediately.

  • When the power line is moved, the unit stops operating.
  • If any control button fails.
  • If the circuit breaker works or the fuse burns out.
  • If the power line or plug is unusually hot.
  • If you notice burning odour or abnormal sound or vibration.
  • If there are any other abnormal phenomena or faults.
  • Stop operating unit, pull out power plug, and contact Customer Service Centre or distributor for inspection and maintenance.
  • Please clean the plug regularly. (If there is dust and moisture on the plug, it may damage the insulation part of the plug and cause fire.)
    •  Pull out the power plug and wipe it with a dry cloth.
    •  Pull out the power plug when the unit is not used for a long time.
  • Make sure disconnect the power supply before maintaining the unit. (Otherwise the unit may suddenly operate, resulting in electric shock or injury.)
  • Ensure that the power cord is securely and completely inserted into the power outlet before use. (Otherwise it may cause fire or electric shock if the power line is overheated.)
    • Do not use damaged power plugs or power sockets.

WARNING

  • ****Do not place the unit in the following places:
  • Unstable place. (Otherwise the unit may be fall off, resulting in injury or damage to the unit.)
  • Bathroom, kitchen or other places with high humidity / temperature. (Otherwise the unit may be damaged or suffer from electric leakage, resulting in fire, electric shock or personnel injury.)
  • Places where oil or flammable gas may leak. (Otherwise fire may occur in the inhaled monitor, leading to fire.)
  • Near heater or other heat sources. (Otherwise the unit may be overheated, leading to fire disaster.)
  • Do not use gasoline or other volatile mixed solvents to wipe the unit. (Otherwise, the unit may rupture or short circuited, resulting in injury, fire or electric shock.)
  • Do not operating the unit while smoking pesticide is used.
  • (Otherwise, the pesticide may accumulate in the unit and then released from the outlet, endangering health.)
  • After using pesticide, the room should be ventilated thoroughly, before the unit can be operated.
  • Do not block the air inlet or outlet by placing clothes, books or other obstacles. (Otherwise, blocking the air outlet may lead to smoke and fire.)
  • Do not sit, stand or lean on this product. (Otherwise, the unit may be overturned, resulting in injury or unit damage.)
  •  If children is around, please supervised carefully.
  • Do not approach the unit with ignited cigarettes, incense and others. (Otherwise, flammables may be sucked into the unit and cause fire.)
  • Do not spray flammable materials such as insecticides or air fresheners around this product

  WARNING

Setting & Operation Requirement

Please pull out the power plug at the hand plug position. (Otherwise, the power line may be damaged, resulting in fire or electric shock.)

PRECAUTION


**It is prohibited to disassemble battery. There are protection mechanisms and protection circuits inside the battery to protect the user. Any improper dismantling will damage the protection mechanisms and possibly cause the battery to get heated, generate smoke and fire.

  • It is prohibited to heat or burn the battery. This may cause the melting of the battery insulator with the loss of its safety function and burn the electrolyte within. High temperatures might cause the battery to overheat, distort the case and lead to smoke and possibly fire.
  • It is prohibited to wet the unit. The unit is installed with an internal battery. Wetting the unit or placing it into water may cause the loss of functionality of the battery protective circuits. This could lead to an abnormal chemical reaction leading to possible heating of the battery, giving off smoke and start a fire.
  • Please avoid charging or operating the unit near a source of fire or under direct strong sunlight. Do not charge or operate the unit near the source of a fire or oven, or in an environment of excessive high temperatures. Overheating could ensue causing functionality loss, short circuit of the battery together with an abnormal chemical reaction. This could overheat the battery leading to smoke and possibly fire.

  WARNING

LITHIUM BATTERY SAFETY PRECAUTION
  • If one observes an undesirable odour from the installed battery, or from other areas within the unit on first-time operation, please do not operate and return to the distributor.
  • Please keep the unit away from an environment involving a heat source, a high barometric pressure or an increasing pressure on the surface of unit during its operation. Place the unit in a secure and safe operating location and away from children.
  • Avoid the unit being shaken in a serious vibrating environment.
  • Please avoid storing or operating the unit in a strong sunlit and hot environment. This will prevent the battery from overheating, becoming distorted, smoking or shortening its life.
  • Please avoid operating the unit in an environment which might conduct static electricity and induce the battery to overheat, distort, generate smoke or shorten its life.
  • Please only charge the battery with the dedicated charger and follow the recommended charging method.
  • Insert battery in correct polarities. It is prohibited to arbitrarily disassemble or refit unit and battery. For safety concern, do not place unit at a wet location.
  • To keep the battery at half-charged condition without any damage and place in the unit a cool dry location when stored for a long period of time.
  • Do not put unit into fire or water.

  WARNING

Patented NCCO Air Purification Technology Brings Fresh and Clean Air

Patented NCCO(Nano Confined Catalytic Oxidation)Air Purification Technology is invented by Member of HKUST Entrepreneurship Program, and has obtained global patents. Our technology can solve indoor air quality problems in an all-round way, create a home / office environment with fresh air, and protect you and your family’s health.

NCCO Technology’s Characteristics
  • Patented NCCO Technology continuously removes bacteria and viruses efficiently.
  • Patented NCCO Technology effectively decomposes carcinogens in the air, such as formaldehyde.
  • Hazardous pollutants will be decomposed into harmless water molecule and carbon dioxide, and will not accumulate in the filter, effectively avoiding re-release into the air due to saturation, and will not cause secondary pollution.
  • Under normal maintenance conditions, NCCO Reactor can be used for a long time. Since there is no need to replace NCCO Reactor frequently, the operating cost is much lower than similar products on the market.
  •  Effectively remove offensive odour.
  •  Patented NCCO Technology has been widely used in different industries, such as schools, hospitals, nursing centers and public toilets.

About Intelligent Power-Off Protection System
b-MOLA NCCO Air Treatment Unit is designed using an Intelligent Power-Off Protection System. The unit will intelligently power off after continuous use over a period of 8 hours and then will restart automatically after 30 minutes downtime once connected to an external power supply. The unit will use the intelligent system to power-off after continuous use of 2 hours, and then will restart automatically after 10 minutes of downtime when using its internal (battery) power supply. Our intelligent power-off system is able to effectively avoid excessive load and eliminate any risk during the supply of power.

Placing Area Guideline

  • dust falls on the floor, it is recommended to place the unit on a flat surface in the room.
  • Excellent Air Circulation Placing the unit on a dry, solid, level surface, and ensure the unit is provided with reasonable space of at least �� cm from any objects, in order to operate effectively.
  • Do not put the unit in the following places:
  • In the direct sunlight; blown by air conditioner; high temperature area. (Otherwise, it may cause deformation, aging, discoloration or reduction of service life.)
  • Distance over � meter to objects such as televisions and radios. (Otherwise, it may lead to image disorders and lost of sound.)
  • Do not place objects at air inlet and outlet. (Otherwise, it may affect the operating performance.)
  • Do not use the same power outlet with TV, radio and other equipment. (Otherwise, it may lead to image disorders and lost of sound.)
  • Please plug into other power outlets.
  • Do not place any items on top of the unit. (Otherwise, the unit may be malfunctioned.)

Main Parts & Components

Illustrationg Diagram:

  • Power Adapter

  • USB Type-C Power Cord

  • Ribbon (Optional)

  • Silicon Rubber Case (Optional)

First-time Operation

  1. Remove all packaging materials, use a soft dry cloth to clean all the parts then re-assemble parts back together.
  2.  Place the unit on a dry, solid, level surface, and ensure the unit is provided with reasonable space of at least �� cm from any objects, in order to operate effectively.
  3.  Check power sockets and any extension cords to confirm compliance with unit requirements. Ensure that the unit is plugged in before usage
  4. The unit is equipped with a sensor. If filters are not installed properly, the unit will not operate.
  5. When the unit is turned on for the first time, warm air and mineral smell may be released from the air outlet. This is normal as catalytic oxidation is taking place inside the NCCO Reactor, and completely harmless to human body.

Installation Procedures

  1. Take out HEPA Filter and NCCO Reactor from protective packaging material.

  2. Slightly push the concave upward to open Air Inlet Cover.

  3. First, put HEPA Filter into NCCO Reactor Frame. Then, install the filter set into unit body

  4. Close the Air Inlet Cover, connect the unit with power supply then press the ON / OFF Button to turn on unit.

Operating Instructions

Operation Method:

ON / OFF Button
After connecting unit with power supply, press ON / OFF Button to switch on unit. The white light indicates the unit operates with Silent Mode.

Press ON / OFF Button again, the unit operates with Silent Mode indicated by blue light.

Press ON / OFF Button for the third time to switch off unit.

The unit is designed with memory function to memorize the last operation mode before switching off.

LED Indicator

When the power ON/OFF indicator flashes in different colours, they indicate following situations:

| Fan Speed| Slow Flash| Fast Flash
---|---|---|---
Blue Indicator| Highest| Running & Charging| Low Power
White Indicator| Lowest| Running & Charging| Low Power

When the indicator flashes white and then blue alternately, it indicates that the unit is off and is charging.

Memory Function
When the external power supply is stopped or interrupted unexpectedly, the unit will automatically transfer to its internal battery power supply. When the battery is exhausted and the unit stops running, it will memorise the operation mode and will return to the previous mode when external power is reconnected to it.

In-Car Installation

(No car charger will be provided.):

A. Put the unit on a flat surface

First, insert the Type-C connector of the power cord into the Type-C jack at the bottom of the unit.

Insert the other end of the power cord into the plug of the car charger, and then insert into the charger socket.

It is not recommended put the unit on the car dashboard, where the surrounding higher temperature may damage the built-in battery.

ATTENTION

  • If the filter set is not installed into the unit, a “DiDiDi” alarm will sound. Please ensure that the filters are properly installed before turning on the unit.
  • When the unit is first turned on (activated), there will be a slight mineral smell.This is perfectly normal and is due to special manufacturing technique of the NCCO Reactor. The smell is harmless and will disappear after a period of time operating the unit.
  •  Please check and ensure that the car power supply is correct. The power input of this unit is DC�V �A.
  • Handle the unit with care.

B. Hang at the back of car pillow:

  1. First, properly place the unit into Silicon Rubber Case. Then, unbuckle the ribbon and put it into case.
    Operating Instruction

  2. Insert the Type-C connector of the power cord into the Type-C jack at the bottom of the unit
    Operating Instruction

  3. Tightly hang the unit with ribbon at the back of car pillow and ensure unit away from swinging.
    Operating Instruction
    Operating Instruction

Rubber Pads Operation Instruction

If user do not place the unit into Silicon Rubber Case, it is suggested to paste Rubber Pads at the back side in order to protect unit.

Cleaning Instructions

Always disconnect the power supply of the unit before any maintenance or care process is carried out (except replacing filters). (Otherwise the unit might still be running and could cause an electrical shock or injury

WARNING

ATTENTION

  • When cleaning the unit, please follow instructions given by the cleaning product. Use a damp clean cloth to wipe the unit.
  • During maintenance, ensure the disassembled parts are kept in a safe and secure place. (Otherwise parts could be lost or damaged.)
  • Do not operate the unit if Filters have not been installed, since this could cause irreversible damage to the unit.
  • If the HEPA Filter is not replaced periodically as indicated in the instructions, it may seriously affect the efficiency of the NCCO Reactor.
Cleaning Instructions
  1. Cleaning External Surfaces of Unit Body
    Please remove Air Inlet Cover before washing it with water (only Air Inlet Cover can be washed with water). The main body of the unit can be wiped with a soft dry cloth but avoid dust falling on the unit.改avoid having dust fall onto the unit during cleaning.
    ATTENTION
    After washing the air inlet cover, please ensure that it is completely dry before replacing onto the main unit.
    Tips : A damp (non-abrasive) cloth can be used to clean the unit surface.

  2. Cleaning Air Inlet and Air Outlet t.
    Use a soft brush or light vacuum to clean the air inlet and air outlet
    ATTENTION
    WARNING:

    Never rinse or soak HEPA Filter or NCCO Reactor in water. When the unit has not been used for a long period of time:

  3. Stop operating unit and pull power plug from power source.

  4. Carry out any maintenance or care work.

  5. Place the unit in a plastic or box carton, and store in a cool dry place.

Filter Replacement & Maintenance

  1. The lifetime of the filter will vary depending on the environment, amount of usage and location of the unit.
  2. To maintain optimal operating condition of the unit, only use the recommended filter.
  3. Turn off the unit before replacing filters.
  4. Please follow HEPA Filter Surface Color Changing Indicator to dispose HEPA Filter.

Recommended Filter Cleaning and Replacement Cycles and Methods

Filters| Cycle| Method
HEPA Filter| Every � – �� Months *| Replacement
NCCO Reactor| Substantial**| Substantia

The filters cleaning and replacement cycle may vary depending on the operating area.

If the HEPA Filter has not been replaced periodically, or it has been damaged, the surface of the

NCCO Reactor is covered with dust or oily substances after disassembling, the removal capacity of  the NCCO Reactor may be badly reduced and should be replaced.

HEPA FILTER SURFACE COLOR CHANGING INDICATOR

No replacement needed| Replacement is recommended| Replacement is needed

FAQs


Unit is making 'DiDiDi' sound and not operating.

lease check if filters have been properly installed. If not, please re-install th


Can HEPA Filter be washed with water?

HEPA Filter is made of composite material, water would seriously affect the purification effect.

The air quality has not improved even after the unit has been turned on for

a long time

If the unit is used in a severely polluted area, the treatment process will take longer. It is recommended to use the HIGH FLOW MODE or extend the operational time until the pollution diminishes.

The unit emits an unusual smell or smog. (e.g. smoke, flame, or burning)

Turn off the unit and disconnect it from power supply right away. Call the customer service center immediately or contact a qualified service agent.

Westinghouse**

Trouble Shooting

Problems Solutions
The unit does not operate. Check if the unit is correctly connected to its

power supply. Turn on the unit.
Unit is making ‘DiDiDi’ sound and not operating.| Check if the filters have been correctly installed. Re-install all filters.
No air is blowing through air outlet.| Check if the unit is correctly connected to its power supply. Check if the power cord interface is in good service condition
The air quality has not improved after a long operation time| If the unit is used in a severely polluted area, the treatment process will take longer. It is recommended to use the HIGH FLOW MODE or extend the operational time until the pollution diminishes.
The Filter may require cleaning and replacement
The airflow from air outlet becomes slow.| Filter may be blocked. Replace the filter. (For the method to install filters, please refer to Page �.)
Make sure all packaging materials are removed.
The unit makes an abnormal noise.| Make sure all packaging materials are removed.
Make sure the air inlet and outlet are not blocked by external objects. Remove all adjacent objects that block the air inlet and outlet.
The unit may malfunction. Call the customer service center for advice or consult with a qualified service provider.
The unit emits an unusual smell or smog. (e.g. smoke, flame, or burning)| Turn off the unit and disconnect it from power supply. Call the customer service center immediately or contact with a qualified service provider.

Product Specification

Power Supply DC 5V 2A
Power Consumption (W) Mode
Highest 2.2
Airflow Volume (m� /hr) Mode
Highest 23
                          Noise Level (dB) Mode
Highest 47.3
Product Dimension (L x W x H) (mm 170l x 78 (w) x 170 (h)
Net Weight (kg) 0.88
Treatment System Active Oxygen Generato
HEPA Filter Remove dust, hair and airborne particles such as allergens and

pollen, bacteria, viruses and fungus.
NCCO Reactor| Remove odour and decompose harmful pollutants such as formaldehyde and VOCs.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Westinghouse User Manuals

Related Manuals