Kosmen KM-250S Industrial Dehumidifier Instruction Manual
- July 3, 2024
- KOSMEN
Table of Contents
Kosmen KM-250S Industrial Dehumidifier
Specifications
- Model: KM-250S
- Manufacturer: www.kosmen.vn
- Indoor use only
- WiFi Connectivity: 2.4GHz
- Recommended Age: 8 years and above
Product Usage Instructions
Important Notice
- Always keep the dehumidifier in a vertical position on a flat surface, maintaining a minimum of 300mm distance from flammable materials.
- Do not obstruct the air suction inlet and radiator grille. Only use indoors and avoid locations like cabinets, closets, boats, or caravans. Allow the unit to stand for one hour after transport or tilting before connecting to the main supply. Ensure the mains supply matches the specifications on the rating plate. Avoid overloading circuits and inspect the power cord regularly.
- Do not unplug the power plug while the dehumidifier is operating. Before moving the unit, turn off all controls, unplug, and empty the water tank. Avoid using bug sprays or flammable cleaners on the unit.
Function of the Button
Operation
- Download the Smart Life or Tuya Smart app on your phone.
- Login/register an account and scan the QR code to connect to WiFi.
- Ensure the dehumidifier, mobile phone, and router are nearby during pairing.
- Follow the app instructions to enter the ready connection status.
Features
The dehumidifier enters standby mode initially. Press the power button and
set the humidity to 3% lower than the current humidity to start the operation.
If set humidity is higher, the dehumidifier will not work.
Important Notice
- Always keep the devices in the vertical position, on a flat surface, and certainly at all times.
- Make sure the minimum of 300mm (1”) between the edges of equipment and any flammable materials.
- Don’t hide the air suction inlet and radiator grille from the divide.
- For indoor use only.
- Not suitable for use in cabinets, closets, boats, caravans, or similar locations.
- Leave the unit to stand for one hour before connecting to the mains supply after transport or when it has been tilted (e.g. during cleaning).
- The mains supply must conform to the specifications shown on the rating plate at the back of the unit.
- Avoid overloading circuits, which are caused by using more electrical amps than your wiring can support. Overloading electrical wires can cause excessive heat and electrical fires.
- Avoid being abandoned.
- Check the power cord carefully. Make sure that it is not punctured or frayed. Inspect the plug to ensure that the prongs are secure and the plastic surrounding it is not cracked.
- Do not suddenly unplug the power plug while the machine is operating. Before turning on or off the machine must use the switch on the control panel.
- Before moving the unit, turn off all controls, then unplug and empty the water tank.
- Don’t use bug sprays or other flammable cleaners on the unit.
- Never pour or spray water over the unit.
- This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be done by children without supervision.
- Only a licensed professional is allowed to dismantle or modify the appliance.
- Suggested to send the appliance for professional maintenance periodically
Function of the Button
Operation
Connect Wifi
- Download the application on the phone, app name “Smart Life” or “Tuya Smart”.
- Log in/register an account.
- Scan this QR code by “Smart Life” or “Tuya Smart”, and connect to the WiFi according to guidance.
- Follow the application’s instructions to enter the ready connection status.
Attention
- When the device is pairing, please confirm the dehumidifier, mobile phone, and router, 3 devices are at a close distance. Try to make them get closer.
- Ensure the network is stable and can be entered.
- Follow the application’s instructions to enter the ready connection status.
- Ensure the WiFi password is correct.
- The device can only connect to Wifi 2.4Ghz
Features
- If the set humidity is higher than the ambient humidity, the dehumidifier will enter the “wet control state” and will not run.
- When entering dehumidification mode, the fan is turned on for 5 to start the compressor; when the dehumidifier stops working, it will first turn off the compressor, then turn off the fan after 30;
- After the compressor is turned off, it takes 3 minutes to restart. When the compressor is running for 72 hours, the system will automatically resume after 30 minutes of forced stop.
- When running at a lower temperature, the machine will automatically detect the system temperature. When the defrosting temperature, it will automatically stop and defrosting. The “snow pattern” will light up and the “defrosting pattern” will shine. After the defrosting, the dehumidifier starts automatically.
- Humidity control operating range: 10%~90%.
- If the dehumidifier has not been used for a long time, remove the power cord or power it off.
- The function of the memory system, the function can function before the power is turned off in 72 hours after the power is lost. (Note: When you leave the humidifier, please turn off the source)
Operating Instructions
When the substrate is powered on for the first time, the substrate enters the
standby state, presses the power button, and sets the required humidity to 3%
less than the current humidity to enter the running state, If the setting
humidity is higher than ambient humidity, the dehumidifier will not work.
Dehumidifying Running
- When the compressor has passed the protection for 3 minutes and the indoor humidity ≥set humidity +5% RH, the compressor will work again.
- When the indoor humidity <set humidity -5% RH, the compressor is turned off.
- Set humidity -5%RH <indoor humidity <set humidity +5%RH to keep the compressor working.
- The compressor stops the fan if it has not been operated 3 minutes after the humidity has dropped.
- Defrost
- After the machine starts to run for 30 minutes, the copper head coil sensor starts to detect the tube temperature. When the tube temperature is ≤ -1°C (there are 3 seconds of detection time), the compressor stops and the fan runs, and the defrosting operation starts. The lights are shining.
- When the temperature sensor detects that the evaporator coil temperature is greater than or equal to 5 degrees and the detection is greater than or equal to 5 degrees for 3 minutes, the defrosting is exited.
Drain Indicator
Continuous Drain
This product has a continuous drain hole that is connected by a plastic tube
(inside diameter is 12mm) through which water can be drained. When using a
water pipe, do not immerse the water outlet in the water to prevent the pipe
from being too long or the pressure forming in the pipe when the water outlet
is blocked. The water flow is not smooth, resulting in water leakage
Inspection and Maintenance
Parts | 1~3 months | 12 months |
---|---|---|
Filter | Clean the filter | |
Compressor | Check if the compressor is normal and the vibration is | |
normal. | Check the compressor cable for signs of looseness, aging, and damage. | |
Heat Exchanger | Clean the duct and sundries. |
Seal
| Check for signs of damage or displacement. If it is worn or damaged, it
should be replaced in time.| Check for signs of damage or displacement. If it
is worn or damaged, it should be replaced in time.
Temp. Control| | Check if all external temperature and
humidity probes are working properly.
Device Installation
The dehumidifier can be installed on many occasions and customized according
to the needs of the user.
Electrical Connection
- The dehumidifier cannot be operated at voltages and frequencies outside the manufacturing range.
- Before switching on the main power supply, the AC power should be checked to ensure that the supplied voltage fluctuation range does not exceed ±10% of the voltage and frequency indicated by the equipment. This check is especially important for voltage fluctuations that can occur in high-load situations.
- The dehumidifier must be grounded and a power disconnect switch set to ensure that the unit is powered off during inspection and service.
- The fuse current of the power supply fuse is 1.5 to 2 times the rated current of the installed dehumidifier. The fuse should be installed in the dehumidifier attachment. The power supply cable and main fuse are optional to handle the correct operating power of the dehumidifier. Fuse rating: 10A 250V, 16A 250V.
- If the power cord is damaged, it must be replaced by the manufacturer or a professional authorized person to avoid danger.
- Placing. When the dehumidifier is working, make sure the
- The minimum distance between two machines is 10cm
- The minimum distance between the air outlet and the top is 200cm
- The minimum distance between the back and the wall is 20cm
Specification
Model | KM- 250S |
---|---|
Application Area | 350-400 m² |
Dehumidifying Capacity | 250L/D |
Operating Power | 3980W |
Amount of Airflow | 2300 m³/h |
Refrigerant | R410A |
Compressor | Panasonic |
Power Supply | 380V /50Hz |
Operating Temp. | 5-38 ℃ |
Water Tank | Drainage |
Dimensions | 6804601710 mm |
Net Weight | 108 KGS |
Error Code explanation
Fault Code | The failure | How to do with it? |
---|---|---|
E1 | Temperature sensor breakdown | To replace with new temperature |
sensor.
E2| Humidity sensor breakdown| To replace with new humidity sensor.
E3| Phase sequence/loss protection (Excluded 220V)| Swap phase sequence
E6| Low voltage protection| Check refrigerant pressure
Troubleshooting
Please do not worry if you encounter the following problems with the use of a dehumidifier. When confirmed as a failure, timely contact for repair.
Problems | Phenomenon/Reason | Solutions |
---|
The dehumidifier does not work.
| 1. Could be a power outage.
2. The power switch is not on. 3. Maybe the fuse has blown out.
4. It’s not the definite starting-up time.
| 1. Please wait for the power supply.
2. Turn on the power switch. 3. Change the fuse.
4. Wait or cancel the time setting.
Unsatisfied dehumidification effect.
|
1. Humidity setting is inappropriate. 2. The front and back may be blocked. 3. Dehumidification time isn’t enough. 4. The door and window may be open.
5. Temperature<5℃ or >38℃.
|
1. Set appropriate humidity. 2. Clear the obstructions.
3. Keep waiting.
4. Close door and window.
5. Be sure the temperature is 5-38℃.
Turn it on immediately after shutdown, it doesn’t work|
3 minutes delay of compressor protection.
|
The machine will work after 3 minutes.
Water leakage
| 1. The drain connection is slack. 2. The drainage system is blocked| 1.
Connect the drain. 2. Clean the stopper.
Frost formation.| There is frost on the surface of the dehumidifier.|
It’s normal, the machine can defrost automatically.
The dehumidifier has a slight wobble.| A slight wobble occurs when
turning on/off the dehumidifier.| It’s a normal phenomenon.
FAQ
Q: Can children use this dehumidifier?
A: Yes, children aged 8 years and above can use the dehumidifier under
supervision or with proper instructions.
Q: Can I dismantle or modify the appliance myself?
A: No, only a licensed professional should handle dismantling or
modifications. It is suggested to send the appliance for professional
maintenance periodically.
References
- Kosmen Việt Nam | Máy Hút Ẩm, Máy Lọc Không Khí Công Nghệ Đức
- Kosmen Việt Nam | Máy Hút Ẩm, Máy Lọc Không Khí Công Nghệ Đức
Read User Manual Online (PDF format)