LUXLOGIC LIGHTING Moon Down Series Surface Mounted Light Instruction Manual
- June 12, 2024
- LUXLOGIC LIGHTING
Table of Contents
LUXLOGIC LIGHTING Moon Down Series Surface Mounted Light
Product Information
The Moon Down Series (Surface Mounted) is a lighting fixture esigned for installation on the ceiling. It comes in various sizes, including 11.8″ (300mm), 15.7″ (400mm), 18.9″ (450mm), 23.6″ (600mm), 35.4″ (900mm), and 47.2″ (1200mm) brackets.
Product Usage Instructions
- Shut OFF the electricity at the electrical panel. Place the wall switch in the OFF position of the room you are installing the fixture.
- Use a screwdriver to relieve the canopy screw a little (Do NOT REMOVE). Rotate the mounting bracket and remove it from the bottom bracket.
- Remove the plastic pin and drill 4 or 6 holes with a diameter of 6mm on the ceiling according to the mounting bracket. Note that if the fixture diameter is larger than 2ft, 6 holes are required (4 for bracket screws and 2 for safety bracket screws). Safety cable suspension is only applicable for diameters of 3ft and above; for diameters of 2ft and below, no safety cable suspension is required.
- Insert the expansion bolts into the holes. Use 2 pcs M4*25mm screws to attach the mounting bracket to the J-Box. Refer to the provided picture for reference. Note that the J-Box should beGarvin 54171-S or equivalent, provided by others.
- Use 4 or 6 pcs (2 for Safe Bracket) M4*25 self-tapping screws to attach the mounting bracket on the ceiling. Connect the safety cable between the mounting bracket and canopy. Ensure that themounting plate is secured at all connection points (junction box plus four outer points for small and medium sizes, or six outer points for larger sizes) to support the fixture weight appropriately. Not using all mounting points could damage the fixture and void the product warranty.
- Use wire connectors to connect the L, N, G, DIM+, DIM- wires. Then place all wires with connectors into the J-Box.
- Keep the slot hole in a vertical line with the side screw. Then, screw into the slot. Next, rotate the lamp body to complete the installation.
- After installation is complete, turn on the electricity at the electrical panel.
Warnings
- Read the installation manual carefully before installation and keep it for future reference.
- Strictly follow the instructions listed in the manual to avoid mis-operation or damage caused by not following the installation manual.
- Ensure that the mounting plate is secured at all connection points to support the fixture weight appropriately. Not using all mounting points could damage the fixture and void the product warranty.
Please read this installation manual carefully before installation. Keep it for future reference! Products are well packed and tested before leaving our factory. Please strictly follow the instructions listed in the manual. Factory cannot be held responsible for any mis-operation or damage caused by not following the installation manual!
Installation Diagram
Step 1
Shut “OFF” the electricity at electrical panel.
Place the wall switch in the “OFF” position ofthe room you are installing the
fixture.
Step2
Use Screw driver to relieve Canopy screw a little.(Do NOT REMOVE). Rotate
Mounting Bracket and Remove it from Bottom Bracket as shown below.
Step3
Remove Plastic Pin,drill 4 pcs or 6 pcs diameter 6mm holes on the ceiling
according to Mounting Bracket. (note: If the fixture dia is larger than 2” , 6
holes are required, 4 for Bracket screw, 2 for safety Bracket screw). Please
note: safety cable suspension is only applicable for diameters of 3ft and
above. For diameters of 2ft and below, no safety cable suspension is required.
Insertthe expansion bolts into the holes.( Use 2 pcs M4*25mm Screws to attach
Mounting Bracketto the J-Box. Refer to picture shown below.
NOTE: J-BOX Garvin 54171-S or equivalent / Provided by others
Step4
Use 4pcs or 6 pcs (2 for Safe Bracket) M4*25 Self-Tapping screw to attach
Mounting Bracket on the ceiling. And Connect the safety cable between Mounting
Bracket and Canopy.
Attention: Must secure mounting plate at all connection points (junction box plus four outer points for small and medium sizes, or six outer points for larger size) to support fixtureweight appropriately. Not using all mounting points could damage the fixture and void product warranty.
Step 5
Use wire connectors to connect L,N,G,DIM+,DIM- wires. Then place all wires
with connectors into J-Box
Step 6
Keep the Slot hole in a vertical line with Side screw. Then, screw into slot.
Next, rotate lamp body To complete installation.
Step 7
After installation is complete, turn on the electricity at the electrical
panel.
Warnings
-
MIN 90 °C SUPPLY CONDUCTORS/LES FILS D’ALIMENTATION 90 °C MIN
-
DAMP LOCATIONS ONLY/POUR EMPLACEMENTS SECS SEULEMENT
-
CAUTION – RISK OF FIRE/ATTENTION – RISQUE D’INCENDIE
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED -
Application temperature for ring light is -20 ° ~40 ° ,humidity is 0~95 % . Otherwise there may be harm to the lifespan of the ring light.
-
Please TURN OFF POWER before installation. This lamp must be installed and maintained by electrician or qualified personnel.
-
Pay attention to fire prevention, electricity and shock resistance.
-
Please do not cover the combustibles on the fixture.
-
All screws and terminals should be tightened and tightly inserted. No loosening and improper connection are allowed.
Attention should be paid to the polarity of components, power supply, driver and so on. -
Terminals should be tightened and tightly inserted. No loosening and improper
BRACKET DIMENSIONS
11.8” (300mm) / 15.7” (400mm)
18.9” (450mm) / 23.6” (600mm)
35.4” (900mm)
47.2” (1200mm)
luxlogiclighting.com | tel. 416-833-5515 toll free. 1-888-553-8003 | info@luxlogic.ca
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>