SCOPREGA GE1S0002 Electric Inflator Instruction Manual
- June 12, 2024
- SCOPREGA
Table of Contents
SCOPREGA GE1S0002 Electric Inflator
ELECTRIC INFLATOR – 12V
SAVE THIS INSTRUCTIONS MANUAL FOR REFERENCE
FUNCTIONAL DESCRIPTION
- FUNCTIONAL DESCRIPTION
- FOREWORD
- PRELIMINARY WARNINGS
- INTRODUCTION
- RECOMMENDED USES
- TECHNICAL SPECIFICATIONS
- GENERAL SAFETY RULES
- STATUS LED
- IMPORTANT CHARGING NOTES
- USE AND OPERATION
- CONNECTING THE ACCESSORIES
- USE OF INFLATOR
- ACCESSORY WARNINGS
- INFLATOR AND BATTERY STATUS MONITORING
TURBOMAX 12V-B IP65
- MAIN SWITCHES (on-off / start)
- LED INDICATORS
- INFLATION PORT
- DEFLATION PORT
- INTEGRATED BATTERY CHARGING SOCKET
FOREWORD
Dear customer,
congratulations on choosing Scoprega.
We design and manufacture products of the highest quality to meet the needs of
our customers. Scoprega offers the highest quality in service as well. Our
specialised departments provide support and instructions when needed, as well
as comprehensive technical service.
We thank you for your trust.
WARNING
Read these instructions before using the inflator. Failure to follow all the instructions listed below may result in damage to the product and/or cause serious injury to persons.
PRELIMINARY WARNINGS
- Comply with all instructions in this document.
- Keep these instructions.
- Do not block the air vents (SEE POINTS 3 e 4 see above).
- Always protect the power cable.
- Do not open the inflator. Refer all servicing to qualified service personnel authorised by Scoprega. Servicing is required when the device is damaged or not working in any way.
- Do not tamper with the product. Opening the inflator will void its warranty.
- Provide suitable ventilation
- Avoid placing objects near the product during operation.
- Keep this product out of the reach of children.
- The operating inflator produces vibrations: therefore, we recommend you to use it on the floor, so as to avoid accidental falls.
INTRODUCTION
The TURBO MAX 12V-B IP65 is a high-efficiency portable electric inflator, with
integrated battery, which stands for reliability and functionality. The
inflator is equipped with two powerful DC motors that drive two turbines
connected in parallel, thus allowing any object to be inflated to a maximum
pressure of 250 mbar.
The inflator is equipped with LED indicators checking pump status during
operation. The inflator starts when the ON button is switched on and the user
push on START button. It automatically stops when it reaches 250 mbar. The
device can be stopped anyway by pushing the OFF button.
RECOMMENDED USES
Large inflatable objects (rubber dinghies / tents / rafts).
TECHNICAL SPECIFICATIONS
ITEM
|
VOLTAGE
(V)
|
FLOW RATE
(L/minutes)
|
MAX.
PRESSURE
(mbar)
|
CHARGE VOLTAGE
---|---|---|---|---
TURBO MAX 12V-B IP65
|
9.5 ÷ 14.5
|
1000
|
250
|
120-240 Vac
50 60 Hz
GENERAL SAFETY RULES
-
ALWAYS TAKE INTO ACCOUNT THE WORKING ENVIRONMENT.
Do not expose the inflator to rain. Do not use in the presence of flammable liquids or gases. -
AVOID UNINTENTIONAL STARTING.
Do not start the inflator with the inlet in contact with dust or water. -
PAY ATTENTION.
Pay attention to what you are doing. Use common sense. -
CHECK THAT THERE ARE NO DAMAGED PARTS.
Before using the inflator, carefully check its outer sides and components. -
DO NOT OPERATE portable inflators near flammable liquids or in gaseous or explosive atmospheres. The inflator motors produce sparks that can release fumes.
-
DO NOT INHALE!
The compressed air coming from the inflator is not clean. Never inhale air from your inflator. -
WARNING! RISK OF EXPLOSION.
Inflate the unit only complying with the manufacturer’s recommendations. Exceeding the pressure rating could cause the inflator to explode, resulting in personal injury. -
NEVER LEAVE THE DEVICE UNATTENDED.
Overinflation could result in serious injury and property damage. -
WARNING! RISK OF UNSAFE OPERATION
Do not modify or attempt to repair the unit. Do not drill into or make any modifications to the inflator or its accessories. Any modification to the product will void its warranty. -
Never carry the inflator by the flexible hose or power cable.
LED INDICATORS
The inflator is equipped with two LED indicators (A and B) that allow the battery status and the pump temperature to be checked. LED A indicates battery level. LED B indicates the operating errors that have stopped inflator operating cycle (refer to paragraph Inflator and Battery Status Monitoring).
IMPORTANT CHARGING NOTES
- A longer life and better performance of the inflator can be achieved if the battery is charged when the air temperature is between 18° – 24°C (65°F and 75°F). DO NOT charge the battery at an air temperature below +4.5°C (+40°F) or above +40.5°C (+105°F). This is important and will prevent serious damage to the battery.
- If the inflator is not used for an extended period of time, it is recommended that the battery be fully recharged at least once a month.
- When recharging, make sure that the power cord is in a protected location so that it will not be stepped on, tripped on, or otherwise damaged or subjected to stress.
- Do not use the power cord if it is damaged.
USE AND OPERATION
CONNECTING THE ACCESSORIES
- Choose the most suitable adapter for the valve on the object to be inflated. During inflation/deflation, the valve should be kept open by a suitable adapter.
- Make sure that the main switch is set to OFF.
- Connect the inflation hose according to the operation to be performed: to inflate: connect to the outlet (item 3, image see above) , to deflate: connect to the inlet (item 4, image see above).
- Insert the adapter into the valve of the object to be inflated/deflated.
USE OF THE INFLATOR
- Set the switch to ON. LED A starts flashing, indicating battery status (refer to paragraph Inflator and Battery Status Monitoring)
- Press the START switch. LED A shifts from flashing to steady, the colour depends on the battery status
- When inflating, the inflator will stop at the set pressure and LED A will resume flashing In the event of an error, the inflator stops as a protective measure. LED B lights up to indicate the type of problem (refer to paragraph Inflator and Battery Status Monitoring). Once the problem has been fixed, the inflator should be restarted by pressing START.
- To deflate, connect the hose to the deflation port and then press START.
- Press the stop button (OFF) once the inflatable unit has been emptied.
DURING THE DEFLATION PHASE, THE INFLATOR DOES NOT SWITCH OFF AUTOMATICALLY.
Once the inflatable unit has been emptied, stop the inflator to avoid overheating the motor and all related risks.
ACCESSORY WARNING
The recommended accessories when using the inflator are the original SCOPREGA
ones.
The use of any accessory not recommended for this inflator can be
dangerous.
INFLATOR AND BATTERY STATUS MONITORING
LED A | LED B | STATUS | POSSIBLE SOLUTION |
---|---|---|---|
OFF | OFF | OFF | |
GREEN flashing | OFF | Stand By CHARGED battery | |
YELLOW Flashing | OFF | Stand By LOW Battery | We recommend you to charge the |
battery before operating.
RED flashing| OFF| Stand By LOW Battery| Charge the battery
GREEN steady| OFF| Operating CHARGED battery|
YELLOW steady| OFF| Operating LOW Battery| We recommend you to charge the
battery before operating.
RED Steady| OFF| Operating LOW Battery| Charge the battery
RED flashing| RED| CYCLE END due to LOW battery| Charge the battery and then
press START to restart the inflator
GREEN flashing| RED| CYCLE END due to UNDER VOLTAGE or OVER VOLTAGE Voltage
below permitted limits| Make sure that the battery voltage complies with the
values indicated in paragraph TECHNICAL FEATURES
Flashing (colour depends on the battery status)| RED flashing| CYCLE END due
to OVER TEMPERATURE| Only after the LED indicators have stopped flashing can
the inflator be restarted by pressing START
WARNING
When connecting the power cable to the battery charging socket, make sure to avoid short circuits and possible fire risk.
WARNING
To recharge the battery, use exclusively the cable supplied with the inflator
WARNING
Do not leave the inflator running unattended. Overinflating an object could result in serious injury.
WARNING
Always check the maximum inflation pressure to avoid risks of explosion.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>