SAFETY PRECAUTIONS

To ensure the best from the product, please read all instructions carefully before using the device. Save this manual for further reference.

  • Unpack the equipment carefully and save the original box and packing material for possible future shipment
  • Follow basic safety precautions to reduce the risk of fire, electrical shock and injury to persons.
  • Do not dismantle the housing or modify the module. It may result in electrical shock or burn.
  • Using supplies or parts not meeting the products’ specifications may cause damage, deterioration or malfunction.
  • Refer all servicing to qualified service personnel.
  • To prevent fire or shock hazard, do not expose the unit to rain, moisture or install this product near water.
  • Do not put any heavy items on the extension cable in case of extrusion.
  • Do not remove the housing of the device as opening or removing housing may expose you to dangerous voltage or other hazards.
  • Install the device in a place with fine ventilation to avoid damage caused by overheat.
  • Keep the module away from liquids.
  • Spillage into the housing may result in fire, electrical shock, or equipment damage. If an object or liquid falls or spills on to the housing, unplug the module immediately.
  • Do not twist or pull by force ends of the optical cable. It can cause malfunction.
  • Do not use liquid or aerosol cleaners to clean this unit. Always unplug the power to the device before cleaning.
  • Unplug the power cord when left unused for a long period of time.
  • Information on disposal for scrapped devices: do not burn or mix with general household waste, please treat them as normal electrical wastes.

Introduction

Introduction to ZT-AP40
ZT-AP40 is a compact-size digital amplifier (Class-D) with 3 inputs (2 line in and 1 balanced MIC). It is integrated with powerful functions, including bridge connection, dual-mono, EQ control, microphone mixer etc. It has a good application in different places, including classroom, small meeting room, lecture hall, bar, pub etc.

Features

  • 2x20Watt@4Ohm as the default amplifier output.
  • Bridge connection function. User can switch the ZT-AP40 to be 1x40Watt@8Ohm by bridge connection.
  • Two stereo audio inputs, switchable by button, IR remote & RS232.
  • Volume/Bass/Treble controllable by buttons IR remote & RS232.
  • MIC port can support balance/unbalance signal, suppress external noise effectively.
  • Line audio output at 3.5mm jack, with volume controllable.
  • Dual-mono function. User can sum up the stereo audio to two times mono audio.
  • MIC mixer function. The microphone will be mixed to the line audio output and be controlled separately.
  • MIC input supports 48V phantom power, dynamic MIC and wireless MIC.
  • Auto noise gate. It keeps detecting the audio and MIC input, will mute the output when there is no input.
  • Ultra-low inrush current, no need for power sequencing. This allows multiple ZT-AP40 to be powered on simultaneously without overloading power circuits.
  • Convection cooler, fan is not needed.
  • Antistatic case design: providing good protection for long-term and stable performance.

Packaging List

  • (1) x ZT-AP40 (The mounting ears and ZT-AP40 are as a whole.)
  • (2) x Pluggable Terminal Blocks
  • (1) x RS232 Cable
  • (1) x Power Adapter
  • (1) x Power Cord
  • (4) x Plastic Cushions

Notes:

  • The IR remote and its battery are offered for charge separately.
  • The IR receiver is also offered for charge.
  • Please confirm if the product and the accessories are all included, if not, please contact with the dealers.

System Connection Introduction

Audio Output

  1. Default Output: 2x20Watt@ 400hm
    The default output of amplifier is 2x20Watt@4Ohm, so user can connect the amplifier output in the regular way. As the picture below:ZENTY-ZT-AP40-40W-
Mini-Amplifier- \(1\)

  2. Bridge Connection: l x40Watt @ 80hm
    The ZT-AP40 has the bridge connection, to double the output power at 1x40Watt@8Ohm. It will sum up the input left channel and input right channel to be mono output, and the power is up to 40Watt. The bridge connection is :ZENTY-ZT-AP40-40W-Mini-Amplifier- \(2\)

  3. Dual-mono Output
    The ZT-AP40 also has the function of double-mono output. It can sum up the left and right channel, to be the mono audio output. In this way, the both of the outputs are showing the same mono audio. The connection is:ZENTY-ZT-AP40
-40W-Mini-Amplifier- \(3\)

Microphone Input
The microphone input of ZT-AP40 has three modes, and different modes use different connections, as the picture below:ZENTY-ZT-AP40-40W-Mini-
Amplifier- \(4\)

  1. 48V Phantom Power Input
    When the switch turns to “48V”, the MIC input will provide a 48V phantom power. This is usually used for power supply for condenser microphone, Connection is: “+” connects to positive, “-” connects to negative and “╧” to ground.
    Note: In this mode, only condenser microphone can be connected with.

  2. MIC Input
    When the switch turns to “MIC”, the microphone input is used for connecting with dynamic microphone. There are two different connections:

  3. Unbalanced connection:
    “╧” connects to ground, and “-” connects to signal.
    “╧” connects to ground, and “+” connects to signal.

  4. Balanced connection: “+” connects to positive, “-” connects to negative and “╧” connects to ground.

  5. LINE Input
    When the switch turns to “LINE”, the microphone input is used for connecting with normal audio or wireless microphone output. There are two different connections:

  6. Unbalanced connection:
    “╧” connects to ground, and “-” connects to signal.
    “╧” connects to ground, and “+” connects to signal.

  7. Balanced connection: “+” connects to positive, “-” connects to negative and “╧” connects to ground.

Operation of Control Panel and IR Remote

Operation of Control Panel
The buttons provide the control of volume/EQ control and switching. The following content introduces audio switching and EQ control in detail.

  1. Audio Switching
    There are two switchable stereo audio inputs, one 2xRCA input, and one 3.5mm jack input, switchable through the buttons as below:

  2. Volume/EQ Controlling
    The line volume and MIC volume can be controlled by the buttons. The MIC Volume/LINE volume/LINE bass/LINE treble will be selected by the buttons, and controlled up/down/mute by the function buttons. Please check the picture below:ZENTY-ZT-AP40-40W-Mini-Amplifier- \(5\)

Usage of IR Remote

ZENTY-ZT-AP40-40W-Mini-Amplifier- \(6\) ZENTY-ZT-
AP40-40W-Mini-Amplifier- \(7\)

System DiagramZENTY-ZT-AP40-40W-Mini-Amplifier-
\(8\)

Communication Protocol and Command Codes

  • Communication Protocol: RS232 Communication Protocol
  • Baud rate: 9600
  • Data bit: 8
  • Stop bit: 1
  • Parity bit: none
Command Function Description Feedback Code
1A1. Switching the audio to input 1 A: 1 -> 1
2A1. Switching the audio to input 2 A: 2 -> 1
0A0. Mute Audio of MIC and Line out Mute
1A0. Mute audio of MIC Mute MIC
2A0. Mute audio of line out Mute LIN
0A1. Unmute Audio Unmute
3A0. Switch on Noise Gate Gate On
4A0. Switch off Noise Gate Gate Off
600% Checking the working status A:          1          ->          1

Volume:                      30

Bass:                          00

Treble: 00

601%| MIC volume up| Volume of MIC: 51
602%| MIC volume down| Volume of MIC: 51
603%| Line volume up| Volume of LINE: 51
604%| Line volume down| Volume of LINE: 51
605%| Bass level up| Bass of LINE: 04
606%| Bass level down| Bass of LINE: 04
607%| Treble level up| Treble of LINE: 04
608%| Treble level down| Treble of LINE: 04
609%| Initialization, back to the default setting| Init OK
5[x][x]%| Preset MIC volume, [xx] arranges from [00] to [60]. 61 degrees in total.| Volume of MIC: 50
7[x][x]%| Preset line volume, [xx] arranges from [00] to [60]. 61 degrees in total.| Volume of LINE: 50
8[x][x]%| Preset the bass level, [xx] arranges from [00] to [08].

9 degrees in total.

| Bass of LINE: 04
---|---|---
9[x][x]%| Preset the treble level, [xx] arranges from [00] to [08]. 9 degrees in total.| Treble of LINE: 04

Notice:

  1. The letter inside bracket [ ] is the variable code, which is changeable.
  2. The bracket [ ] is not included to the RS232 commands.
  3. Any dot “.” after the letters is part of the commands
  • Example 1:
    Switching the input 2 to the line out, RS232 command is: [2A1.]

  • Example 2:
    Turning up the volume of line audio, RS232 command is: [603%]

  • Example 3:
    Preset the MIC volume to “21” degree, RS232 command is: [521%]

  • Example 4:
    Checking the working status of ZT-AP40, RS232 command is: [600%]

Specifications

Audio Input Audio Output
Input 2 stereo audio, 1 MIC
Input Connector 2 RCA 1 3.5mm jack 1 pluggable terminal block (3P,3.81mm),
Output Connector 1 3.5mm jack 1 pluggable terminal block (4P, 5.08mm)
Input Impedance >10KΩ

Audio General
Frequency Response| 20Hz ~ 20KHz| CMRR| >70dB@20Hz~20

KHz

---|---|---|---
SNR| 80dB at maximum

output

| Bandwidth| 20Hz ~ 25KHz
Stereo Channel Separation| >75dB@20Hz to 20KHz| THD + Noise| 1%@1KHz,

0.3%@20KHz

at nominal level

Voltage Gain| 32dB| Power

Output

| 2×20 Watts (4

Ohms)

 | Control Function
RS232 Control| 3-hole phoenix connector| Panel

Control

| Optional button

control

IR Remote| Optional IR remote

Panel Drawing

ZENTY-ZT-AP40-40W-Mini-Amplifier- \(9\)

Maintenance
Clean this unit with a soft, dry cloth. Never use alcohol, paint thinner, or benzene to clean.

Warranty

If your product does not work properly because of a defect in materials of workmanship, our company (referred to as “the warrantor”) will, for the length of the period indicated as below, “Parts and Labor (5) Years”, which starts with the date of original purchase (“Limited Warranty Period”), at its option either (a) repair your product with new or refurbished parts, or (b) replace it with a new or a refurbished product. The decision to repair or replace will be made by the warrantor. During the “Labor” limited warranty period, there will be no charge for labor. During the “Parts” warranty period, there will be no charge for parts. You must mail in your product during the warranty period. This Limited Warranty is extended only to the original purchaser and only covers products purchased as new. A purchase receipt or other proof of the original purchase date is required for Limited Warranty service.

Mail-In Service
When shipping the unit, carefully pack and send it prepaid, adequately insured, and preferably in the original carton. Include a letter detailing the complaint and provide a daytime phone and/or email address where you can be reached.

Limited Warranty Limits and Exclusions
This Limited Warranty ONLY COVERS failures due to defects in material or workmanship and DOES NOT COVER normal wear and tear or cosmetic damage. The Limited Warranty ALSO DOES NOT COVER damages which occurred in shipment, or failures which are caused by products not supplied by the warrantor, or failures which result from accidents, misuse, abuse, neglect, mishandling, misapplication, alteration, faulty installation, set-up adjustments, mis- adjustment of consumer controls, improper maintenance, power line surge, lightning damage, modification, or service by anyone other than a Factory Service center or other Authorized Servicer, or damage that is attributed to acts of God. THERE ARE NO EXPRESS WARRANTIES EXCEPT AS LISTED UNDER “LIMITED WARRANTY COVERAGE”. THE WARRANTOR IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THIS PRODUCT, OR ARISING OUT OF ANY BREACH OF THIS WARRANTY. (As examples, this excludes damages for lost time, cost of having someone remove or re-install an installed unit if applicable, travel to and from the service, loss of or damage to media or images, data or other recorded content. The items listed are not exclusive, but are for illustration only.) PARTS AND SERVICES, WHICH ARE NOT COVERED BY THIS LIMITED WARRANTY, ARE YOUR RESPONSIBILITY.

WWW.ZENTY.COM
9807 EMILY LANE
STAFFORD, TX 77477
844-200-1945
SUPPORT@ZENTY.COM
SALES@ZENTY.COM

ZENTY ®
9807 EMILY LANE
STAFFORD, TX 77477
844-200-1945
SUPPORT@ZENTY.COM

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals