tobii dynavox PCEye 5 Combines Outdoor Eye Tracker Instructions

June 12, 2024
tobii dynavox

tobii-dynavox-logo

tobii dynavox PCEye 5 Combines Outdoor Eye Tracker

tobii-dynavox-PCEye-5-Combines-Outdoor-Eye-Tracker-
produict

Product Information

The PCEye 5 by Tobii Dynavox is an advanced computer system and electronic device that allows users to control their computer using eye movements. It emits pulsed infrared (IR) light when activated and is designed to be mounted on a monitor or laptop using approved mounts.

Safety

Mounting Warning
The PCEye 5 should be mounted according to the instructions provided with the approved mounts. Tobii Dynavox and its agents are not responsible for any damage or injuries caused by the device falling from a mounted configuration. Mounting the PCEye 5 is done at the user’s own risk. The double-sided tape supplied with the adhesive Magnetic Mounting Plates (if applicable) is designed for permanent attachment to the monitor/laptop. Removing the bracket after attaching it with the tape may result in damage to the monitor/laptop and the bracket. Do not lick or place any part of the adhesive tape or Magnetic Mounting Plate in your mouth or on your body.

Do not mount the PCEye 5 on monitors positioned above the head or face of a user unless using a dedicated fixed mounting solution.

Epilepsy Warning
Some people with Photosensitive Epilepsy may experience epileptic seizures or loss of consciousness when exposed to certain flashing lights or light patterns, even without a medical history of epilepsy. Use caution when using the PCEye 5 if you have Photosensitive Epilepsy.

Infrared Warning
The PCEye 5 emits pulsed infrared (IR) light when activated. Certain medical devices may be affected by IR light and/or radiation, potentially inhibiting their accuracy or functionality. Avoid using the PCEye 5 in the vicinity of such susceptible medical devices.

Magnetic Field Warning
The PCEye 5 Magnetic Mounting contains magnets that may interfere with the function of cardiac pacemakers and implantable cardioverter-defibrillators. Maintain a minimum distance of 6 inches (15 centimeters) between any item with magnets and your heart device.

Child Safety
The PCEye 5 is composed of multiple separate, assembled parts. Some of these parts may pose a choking hazard or other danger to young children if separated from the device. Ensure that young children do not have unsupervised access to or use of the device.

Do not open PCEye 5
Opening the PCEye 5 will void the warranty as there are no user-serviceable components inside. If your PCEye 5 is not working properly, contact Tobii Dynavox Support for assistance.

Emergency
The PCEye 5 should not be relied upon for emergency calls or banking transactions. It is recommended to have multiple communication methods in emergency situations. Banking transactions should only be carried out using systems recommended and approved by your bank.

Computer Control
Using Computer Control with the PCEye 5 may cause fatigue or dryness of the eyes due to intentional eye focusing and less frequent blinking. Start off slowly and limit the length of your Computer Control sessions to your comfort level. Remoisturizing eye drops can help alleviate dryness.

Safety and Compliance PCEye 5 by Tobii Dynavox

Safety

Mounting Warning

  • The PCEye 5 should be mounted according to the in-structions of the approved mounts used. Tobii Dyna-vox or its agents are not liable for damage or injuries to a person or its property due to a PCEye 5 falling from a mounted configuration. The mounting of a PCEye 5 is done entirely at the user’s own risk.
  • The double sided tape supplied with the adhesive Magnetic Mounting Plates (if applicable) is designed to permanently attach the bracket to the monitor/lap-top. Attempting to remove the bracket after attaching it using the supplied tape can result in damage both to the monitor/laptop and the bracket.
  • Do not lick the adhesive tape or place any part of the tape or Magnetic Mounting Plate in one’s mouth or on one’s body.
  • Do not mount the PCEye 5 on monitors positioned above the head or face of a user unless using a dedicated “fixed mounting” solution.

Epilepsy Warning
Some people with Photosensitive Epilepsy are susceptible to epileptic seizures or loss of consciousness when exposed to certain flashing lights or light patterns in everyday life. This may happen even if the person has no medical history of epilepsy or has never had any epileptic seizures.

A person with Photosensitive Epilepsy would also be likely to have problems with TV screens, some arcade games, and flickering fluorescent bulbs. Such people may have a seizure while watching certain images or patterns on a monitor, or even when ex-posed to the light sources of an eye tracker. It is estimated that about 3-5% of people with epilepsy have this type of Photosensitive Epilepsy. Many people with Photosensitive Epilepsy experience an “aura” or feel odd sensations before the seizure occurs. If you feel odd during use, move your eyes away from the eye tracker.

Infrared Warning
When activated, the PCEye 5 emits pulsed infrared (IR) light. Certain medical devices are susceptible to disturbance by IR light and/or radiation. Do not use the PCEye 5 when in the vicinity of such susceptible medical devices as their accuracy or proper functionality could be inhibited.

Magnetic Field Warning
The PCEye 5 Magnetic Mounting contains magnets. Magnetic fields may interfere with the function of cardiac pacemakers and implantable cardioverter-defibrillators. As a general rule, maintain a minimum distance of 6 inches (15 centimeters) between any item with magnets and your heart device.

Child Safety
The PCEye 5 is an advanced computer system and electronic device. As such it is composed of numerous separate, assembled parts. In the hands of a child certain of these parts have the possibility of being separated from the device, possibly constituting a choking hazard or another danger to the child. Young children should not have access to, or use, the device without parental or guardian supervision.

Do not open PCEye 5
Non-compliance will result in loss of Warranty! There are no user- serviceable components inside. Contact Tobii Dynavox Support if your PCEye 5 is not work-ing properly.

Emergency
Do not rely on the device for emergency calls or banking transactions. We recommend having multiple ways to communicate in emergency situations. Banking transactions should only be carried out with a system recommended by, and approved according to the standards of your bank.

Computer Control
Some people may experience a certain amount of fatigue (due to intentional eye focusing and hard concentration) or even dryness of the eyes (due to less frequent blinking) when first getting used to Computer Control. If you are experiencing fatigue or dry eyes start off slowly and limit the length of your Computer Control sessions to your comfort level. Remoisturizing eye drops can be helpful to combat dryness.

Third-Party
Tobii Dynavox assumes no responsibility for any consequence resulting from use of the PCEye 5 in a manner inconsistent with its intended use, including any use of the PCEye 5 with third-party software and/or hardware that changes the intended use.

Compliance Information

The PCEye 5 is CE-marked, indicating compliance with the essential health and safety requirements set out in European Directives.

FCC Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Modifications not expressly approved by Tobii Dyna-vox could void the user’s authority to operate the equipment under FCC rules.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to a wall outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or experienced radio/TV technician for assistance.

Industry Canada Statement

This Class B digital apparatus complies with Canadian ICES-003.

CE Statement
The PCEye 5 complies with the following Directives:

  • 2017/745 (MDR) Medical Device Regulation
  • 2011/65/EU (RoHS) – Restriction of Hazardous Substances Directive
  • 2014/30/EU (EMC) – Electromagnetic Compatibility Directive

Standards
The PCEye 5 complies with the following standards:

  • FCC part 15, Class B
  • ICES-003 Issue 6:2016 Class B
  • EN 55032: 2012+AC: 2013 Class B
  • EN 55024:2010+A1:2015
  • EN 61000-3-2: 2014
  • EN 61000-3-3: 2013
  • AS/NZS CISPR 32:2015

Customer Support

For support, please contact your local representative or Tobii Dy-vox Support. In order to receive assistance as quickly as possible, make sure you have access to your PCEye 5 and, if possible, an Internet connection. You should also be able to supply the serial number of the device, which you find on the back of the device. Find our Support pages online at: www.tobiidynavox.com or www.myTobiiDynavox.com.

Disposing of the PCEye 5

Do not dispose of the PCEye 5 in the general household or office waste. Follow your local regulations for the disposal of electrical and electronic equipment.

12008590 PCEye 5 Safety and Compliance v.1.0.2.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals