ROHL AKIT2202NLMMB Lombardia Floor Mounted Tub Installation Guide
- June 9, 2024
- ROHL
Table of Contents
ZA386 FLOOR LEGS
ASSEMBLY INSTRUCTIONS
AKIT2202NLMMB Lombardia Floor Mounted Tub
Installation requirements: 2 x 1/2” NPT male stub outs at 5 29/32” center
Please note: if installing with an Italian Bath exposed tub filler you
must install a set of adaptors C5574EXT
-
Apply Teflon tape to the male connections.
-
Hand tighten, then turn with a strap wrench % to % turn to make a seal.
WARNING: Do not over tighten. Over tightening could cause the brass to crack.
Test for leaks before installing floor escutcheons.
Please note that the threaded connection only ensures hydraulic water tightness, mechanical fixing of floor legs is ensured by the whole part assembly of components listed as 1-2-3-4-5 in picture 4. -
Slide on base escutcheons (1) and the cut bushings (2).
Mark the screw holes for drilling. -
Drill a hole using a 13/32″ drill and install floor anchors (3).
Slide the base escutcheons (1) to the floor, align with holes and tighten Allen screws (4) using a 5/32″ Allen wrench.
Insert the cut bushings (2) into the base escutcheons (1) and slide on the threaded ring (5). Then tighten using a 1 7/16″ wrench. -
Install elbow unions (6) to pillar legs, using a 1 3/16″ wrench, ensuring that all washers create a seal.
Install tub faucet to elbow unions using a 1 3/16″ wrench, ensuring that all washers create a seal.
ATTENTION
READ THESE INSTRUCTIONS BEFORE INSTALLATION AND USE OF ALL FAUCETS AND WALL
VALVES
INSTALLATION and WARRANTY INSTRUCTIONS
TECHNICAL INFORMATION
All flexible hoses are designed and manufactured for use with water in exposed
locations only. Do not expose to household cleaners, chlorine, chloride,
hydrochloric acid or other corrosive chemicals.
– All connections with threads M10x1 male must be hand tighten. Do not over
tighten. Over tightening may cause damage to the hose.
All faucets washers and O-rings are designed and manufactured for use with
water. Do not expose to household cleaners, chlorine, chloride, hydrochloric
acid or other corrosive chemicals.
Faucets are designed for use with the temperatures and pressures listed below:
- minimum cold water supply 50 °F
- maximum hot water supply 145 °F
- minimum pressure 15 psi
- maximum pressure 75 psi
- maximum fixing torque value = 10 lbf.ft.
Please note: The recommended best pressure for best performance is between 40 psi and 60 psi. More pressure than 60 psi or less pressure than 40 psi may affect the diverting action in side spray faucets.
-
Do not use any Roehl Country/ Nicolazzi faucet with sulphorous water.
-
The minimum temperature for all faucets is 50 degrees F. Below 50 degrees F will void the warranty.
-
When available, filter systems must be placed between hot and cold supply lines and the faucet.
Improper use or non-use of filters may make diverting faucets with hand sprays perform poorly. -
Don’t modify faucet and their components O Use only original spare parts if there are replacements to be ordered.
-
Installation must be made by authorized plumbers or installers. Improper installation or diagnosis of problems is not covered by the warranty.
-
Yearly maintenance of cleaning and flushing is recommended.
Operation and use of any faucet or wall valve that do not conform to these technical instructions will void the warranty.
Documents / Resources
| ROHL
AKIT2202NLMMB Lombardia Floor Mounted
Tub
[pdf] Installation Guide
AKIT2202NLMMB Lombardia Floor Mounted Tub, AKIT2202NLMMB, Lombardia Floor
Mounted Tub, Floor Mounted Tub, Mounted Tub
---|---
References
- Cisal | Rubinetti Design per il Bagno e per la Cucina
- House of Rohl | Handcrafted Kitchen & Bath Fixtures