FIELD CONTROLS TRIO Plus S Air Cleaner User Manual
- June 9, 2024
- FIELD CONTROLS
Table of Contents
FIELD CONTROLS TRIO Plus S Air Cleaner
SAFETY PRECAUTIONS
Please read the instructions carefully and completely before proceeding with the installation of the product to better understand the product and to prevent personal injury and damage.
WARNING: Failure to follow the instructions below can damage the product or cause personal injury.
- To reduce the risk of fire or electric shock, do not use this appliance with any solid-state speed control device.
- Do not spray any paint, insecticide, ethyl alcohol, or any other chemical agent on the appliance’s surface. It can cause a crack, electric shock, or fire. If there is a chemical accumulated inside of the device, it will be discharged from the air outlet and dispersed back into the living space. Please ensure the room is well ventilated if using any of the listed chemicals.
- The air purifier should not be used in a flammable and combustible environment or environment with corrosive air.
- When the device is on, please do not touch the air inlet or outlet, or put a hand or any object into the air outlet so as to prevent injury or damage to the product.
- Do not sit on or place any objects on the device.
- Device is designed for indoor, dry location installation. Not intended for bathroom or high humidity enviornment. Improper usage may cause fire, electric shock, or malfunction.
- Do not modify, dismantle or repair the appliance. This may cause fire, electric shock, or malfunction.
- This appliance is equipped with a polarized plug (one blade is wider than the other). Toreduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way.
- If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.
- Do not use the appliance if the power cord or plug is broken, damaged, and/or defective. This can cause electric shock or fire. Do not touch the power cord with a wet hand.
- To reduce the risk of fire, electric shock or injury to persons, do not use replacement parts that have not been recommended by the manufacturer.
- Please clean the foundation and remove the primary filtration net of the PM2.5 module to make sure the appliance performs as intended.
- Unplug the device from the wall before moving or performing any maintenance.
- Unplug the device from the wall if it will not be used for an extended period of time.
- Turn the device off and unplug from the wall if there is a peculiar smell coming from the appliance. Contact manufacturer technical support if this occurs.
- Do not place foreign objects into the air outlet. Please check the unit for foreign objects before use.
- The air purifier should be placed at least 20in (50cm) from the wall or other objects.
- Unplug or disconnect the appliance from the power supply before performing any service or maintenance on the appliance.
- This product complies with the maximum allowable concentration of ozone of 0.050 parts per million by volume (ppmv) in a 24-h period.
PRODUCT OVERVIEW
Terminology
Specifications
PRODUCT MODEL
| ****
Plus s
---|---
Rated Voltage (V)| 120
Rated Power (W)| 90
Frequency (Hz)| 60
CADR Rating (CFM)| 350
Airflow (CF)| 504
Sound (dBA)| 53
Weight| 26.2
Dimensions W x H x D (inches)| 17.3 x 28 x 9
OPERATION INSTRUCTIONS
Air quality is classified into five levels: Healthy, Good, Fair, Unhealthy, and Poor. The different colors of the air quality indicator light represent the air quality in different states.
Air | Speed | Air Quality Indicator |
---|---|---|
Poor | 5 | Red |
Unhealthy | 4 | Orange |
Fair | 3 | Yellow |
Good | 2 | Green |
Healthy | 1 | Blue |
IAQ Note
Warning: The sensor and air purifier are not medical devices and the information they provide is not intended to diagnose,treat, cure,or prevent any disease or condition. Consult your doctor if you are unsure what levels of particulate matter are safe for you and visit www.airnow.gov for more information on particulate matter and all aspects of air pollution.
Control Panel Operating Instructions
No | Symbol | Symbol Name | Meaning |
---|---|---|---|
1 |
Filter
|
The filter indicator will blink when the filters need to be checked or replaced. After the filters have been inspected and/or replaced, press and hold the filter indicator for
5 seconds to reset the filter indicator.
2| |
Child Lock
|
Press and hold for 5 seconds to turn ON/OFF the child lock. All buttons, except the child lock, are disabled when the child lock is ON.
No | Symbol | Symbol Name | Meaning |
---|---|---|---|
3 |
|
Timer (1H/
2H/
4H/
8H)
|
Set the timer to control how long the purifier should operate. Press to cycle between different lengths of time. The timer light will toggle between remaining hours according to time left until shutting down.
4| |
Speed 1-5
|
For manual mode (M T) , press and cycle between the 5-speed options by pressing the manual speed button. The purifier will
stay in Manual mode and the selected speed, regardless of the air quality reading, unless turned off or switched to another mode.
No | Symbol | Symbol Name | Meaning |
---|---|---|---|
5 |
|
Auto Mode
|
When the purifier is on, cycle between modes by pressing the mode button.
In AUTO mode, the air speed will be adjusted automatically between speeds 1-5 according to the air quality level.
The purifier is equipped with a light sensor and will scan the environmental light in AUTO mode. The purifier will switch to
SLEEP mode after being in dark surroundings for 5 minutes. If the purifier picks up light for
5 minutes, the purifier will exit sleep mode and return to AUTO mode.
MT
Mode
|
Manual Mode
The purifier operates on the speed setting adjusted by the user. Upon switching to M T mode, the speed automatically resets to speed 1.
No | Symbol | Symbol Name | Meaning |
---|---|---|---|
|
Sleep Mode
|
Control Panel lights will dim, the air quality indicator will turn off and the button beep sound will be silenced.
Speed and timer are adjustable in sleep mode. Button luminance will return to normal upon exiting SLEEP mode.
When the purifier is entering sleep mode, an eight hour timer will automatically begin.
The timer can be turned off manually.
Turbo Mode
| The purifier operates at maximum speed. Exit Turbo Mode by adjusting speed
manually or switching to another mode.
6| |
Power
|
Press to turn the purifier ON or OFF.
Getting Started
Setting up the TRIO Plus S
Before using the appliance, remove all the packaging materials covering the filters and place the filters back into the appliance as described in the following steps
Note: Please ensure that the correct filter installation sequence is followed. Otherwise, there may be damage to the product and the filtration efficacy of the unit may not be as effective as advertised.
- Step 1: With both hands on the upper side of the appliance, first pull the front case in the direction 1, then lift the front case in direction 2.
- Step 2: Press down on Pre-filter screen tabs and pull outwards. Remove packaged pre-filter from pre-filter screen frame and then remove filter from package.
- Step 3: Remove each filter from appliance and remove from packaging.
- Step 4: Place the HEPA filter as shown in the figure. Grasp the HEPA filter, as shown and place the HEPA filter back into the appliance with the tag pointing towards you.
- Step 5: Slide the pre-filter into the pre-filter frame from the bottom. Then place the bottom of the pre-filter frame into the slots on the bottom of the appliance and press the top towards the appliance.
- Step 6: Place front cover on the unit once all the filters have been installed. Slide the front cover slots on the base into the slots on the appliance (direction 2) and then push the top towards the unit until the cover clicks closed.
MAINTENANCE INSTRUCTIONS
To increase the life of the air purifier, perform regular maintenance and care. Before performing maintenance, be sure to shut down the air purifier and unplug the power plug from the power source.
Note: HEPA filters is best replaced every 3 to 6 months, depending on the use situation. High-efficiency HEPA filters and pre-filters cannot be washed.
Filter Indicator Timing
The TRIO Plus S calculates the recommended replacement of the filter based on operation time and fan speed. If the unit is run at higher speeds, the filters will likely capture more particles, and require replacement earlier than if the purifier was run at low speeds, filtering less air. It is recommended that the filter kit (Pre-filter, HEPA filter) be replaced every 6 months of operation.
Cleaning of the Appliance
- Clean the air purifier once a month. If the operating environment is poor, increase the cleaning frequency.
- Before cleaning, turn off the appliance and unplug from the power source.
- When Cleaning or Servicing this appliance use OSHA approved safety glasses, gloves and mask.
- Clean it with a soft, dry cloth. Do not use alcohol, gasoline, benzene or other chemical solvents for cleaning.
Clean Pre-Filter
- It is recommended that the pre-filter screen be cleaned using a dust collector, as shown, approximately every 1 to 3-months.
- This will extend the life of the HEPA filter and ensure the unit is running optimally.
Filter Replacement Steps
Before replacing the filter, turn off the appliance and unplug from the power source.
- Step 1: With both hands on the upper side of the appliance, first pull the front cover in the direction of 1, then lift the front cover in the direction of 2.
- Step 2: Press the clasps of the pre-filter frame down, releasing the frame, then pull the pre-filter towards you. Pull the pre-filter down and out of the frame. Carefully place the used pre-filter into disposable bag. Save the Pre-filter screen frame.
- Step 3: Pull the tag of the HEPA filter to remove the filter from the air purifier. Carefully place used filter into disposable bag.
- Step 4: Insert new pre-filter into pre-filter frame. Place the bottom of the pre-filter frame into the slots on the bottom of the appliance and press the top towards the appliance until the clasps click closed.
- Step 5: Place the front panel’s hooks into the air purifier slots at the bottom then press the top towards the air purifier.
COMMON PROBLEMS AND SOLUTIONS
Problem | Possible Causes | Remedial Action |
---|
The
| ****
If the power light is off,
| ****
Confirm the unit is
appliance| the unit is:| plugged in.
does not|
- Not plugged in, or
| Confirm all filters and
turn on|
- The filters or front panel is
| front panel are correctly
| not installed correctly.| installed.
| ****
There is a problem with the
| ****
Please check whether
Product| power connection;| the plug is inserted into
works| The filter cover is not| the socket and check
abnormally| placed properly.| On/Off button status;
| | Re-install the filters.
Fresh air
| ****
The plastic package of the new filter is not removed; The air outlet of purified is blocked by foreign matter.
|
cannot be|
delivered
from the air
| Remove any packaging from the filter.
outlet|
smoothly|
Problem Possible Causes Remedial Action
Poor odor removal
| ****
The ambient air quality of the room is poor.
Inlet and or outlet restricted. The filters need to be replaced.
Packaging have not been removed.
The room exceeds the effective area of the product.
| ****
Open the window to improve ventilation.
Replace the filter.
The appliance generates abnormal sound while running
| ****
The air inlet or air outlet is blocked by foreign matter; A foreign object has fallen into the airflow path of the appliance.
| ****
Unplug and remove the object blocking the air flow; Remove any foreign objects in the appliance.
The unit is always detecting high levels of particles
| ****
The sensor cover is dusty; The unit operated in a dusty environment.
| ****
Clean the sensor cover; Sensor may require opening and sensor to be carefully cleaned with a damp Q-Tip
Adjust the air purifier operating speed to high speed.
Problem | Possible Causes | Remedial Action |
---|---|---|
Outlet Smell |
- Time to replace the filters.
- The filter has absorbed too much odor or smoke.
|
- The odor gradually disappears after running the appliance for a period.
- Clean or replace the filters.
The above table lists the common problems with this product.
- Need Support? Call us at 252 522 3031
- Office hours are 8am – 5pm EST.
TRANSPORTATION AND STORAGE CONDITIONS
It is recommended that the equipment be transported and stored under the following conditions
Ambient Temperature | Environmental Humidity | Atmospheric Pressure |
---|
-40℃~+50℃
-40F to 122F
| ≤80% RH| 70~106kPa 10 psi – 15 psi
Note
- This package includes an air-purifying appliance and an instruction manual.
- If parts are missing after unpacking, please contact the after-sales service staff.
This manual may be downloaded and printed from the Field Controls website
WARRANTY
For warranty information about this or any Field Controls product, visit: FieldControls.com/warranty
SUPPORT
Documents / Resources
|
FIELD CONTROLS TRIO Plus S Air
Cleaner
[pdf] User Manual
TRIO Plus S Air Cleaner, TRIO Plus S, Air Cleaner
---|---
|
FIELD CONTROLS TRIO Plus S Air
Cleaner
[pdf] Instruction Manual
TRIO Plus S Air Cleaner, TRIO Plus S, Air Cleaner, Cleaner