Product Information
The product is a hanging fixture with item number P1360-619/66A. It comes with a metal support plate, canopy, glass shade, and ten candelabra base bulbs (not included). The fixture has three rods (F1, F2, and F3) that can be threaded to adjust the hanging height. The installation requires drywall anchors, mounting screws, and wood screws. The fixture has black or smooth wires for hot connection, white or ribbed wires for neutral connection, and bare copper wires for ground connection. The product is rated for a maximum wattage of 60 watts per bulb.
Product Usage Instructions
-
Unpack the fixture and ensure that all parts are included.
-
Turn off power at the circuit breaker and remove the old fixture including the mounting hardware.
-
Thread rods (F1, F2, and F3) to all thread (J) on the fixture body. Pass the wires through each rod during assembly and secure swivels (G) onto rods (F1).
-
Align canopy (H), metal support plate (I), lock washer (L), and metal washer (E) onto swivels (G) and secure with hex nuts (D) via wrench (J).
-
Position mounting plate (A) on the ceiling and mark the location of the two drywall anchors (K). Pre-drill the holes for the drywall anchors (K). Insert the drywall anchors (K) into the ceiling and attach mounting plate (A) to the junction box using mounting screws (B) and wood screws (O) into drywall anchors (K).
The side of the mounting plate marked GND must face out. -
Connect the electrical wires as shown in Fig. 2, making sure that all wire connectors are secured. If your junction box has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to mounting plate (A) using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
-
Align canopy (H) over mounting plate (A) and secure with screws (C).
-
Place glass shade (M) over socket (L) and secure with screw shell (N).
-
Install ten candelabra base bulbs (Q) up to 60 watts each or CFL or LED equivalent (not included) in accordance with the fixture specification. Do not exceed the maximum wattage rating.
-
The dendrites of this lamp have the function of rotating a certain angle so that customers can make their own adjustments.
-
Turn on power at the circuit breaker and test the fixture.
Note: The illustration in Fig. 1 is for installation purposes only and may or may not be identical to the purchased fixture. The fixture should be installed by a qualified electrician to ensure proper wiring and installation.
INSTALLATION INSTRUCTIONS
Item#P1360-619/66A (New. 2022/06/15)
READ AND SAVE THESE INSTRUCTIONS
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER.
HANGING THE FIXTURE (Fig. 1)
-
Carefully remove the fixture from the carton and check that all parts are included as shown in the illustration.
-
Shut off power at the circuit breaker and remove the old fixture including the mounting hardware.
-
Determine the desired hanging height and thread rods (F1, F2 and F3) to all thread (J) on the fixture body. Carefully pass the wires through each rod during assembly. Secure swivels (G) onto rods (F1).
-
Align canopy (H), metal support plate (I) followed by lock washer (L) and metal washer (E) onto swivels (G) and secure with hex nuts (D) via wrench (J) (not included).
-
Position mounting plate (A) on the ceiling and mark the location of the two drywall anchors (K). Pre-drill the holes for the drywall anchors (K). Then insert the drywall anchors (K) into the ceiling.
-
Attach mounting plate (A) to the junction box (not included) using mounting screws (B) (Size: #8-32N*L0.5”) and wood screws (O) into drywall anchors (K). The side of the mounting plate marked “GND” must face out.
CONNECTING THE WIRES (Fig. 2)
-
Connect the electrical wires as shown in Fig. 2, making sure that all wire connectors are secured. If your junction box has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to mounting plate (A) using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
COMPLETING THE INSTALLATION (Fig. 1) -
Align canopy (H) over mounting plate (A) and secure with screws (C).
-
Place glass shade (M) over socket (L) and secure with screw shell (N).
-
Install (10) ten candelabra base bulbs (Q) up to 60 watts each or CFL or LED equivalent (not included) in accordance with the fixture specification.
- DO NOT EXCEED THE MAXIMUM WATTAGE RATING! (NE PAS DEPASSER LA PUISSANCE NOMINALE MAXIMALE!).
-
The dendrites of this lamp have the function of rotating a certain angle so that customers can make their own adjustments.
Your installation is now complete. Return power to the junction box and test the fixture.
Note: Illustration (Fig. 1) on this manual is for installation purposes only. It may or may not be identical to the fixture purchased.
IMPORTANT: FIXTURE SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN TO ENSURE PROPER WIRING AND INSTALLATION.