Leica HG-DC1 Wireless Charging Handgrip User Manual

October 30, 2023
Leica

HG-DC1 Wireless Charging Handgrip

Leica-HG-DC1-Wireless-Charging-Handgrip-product-image

Product Information: Wireless Charging Handgrip HG-DC1

The Leica Wireless Charging Handgrip HG-DC1 is an accessory that allows inductive charging of the rechargeable battery of your camera (in conjunction with a compatible charging station). It has a double-insulated design and is rated at 9.0 V DC/1.1 A. The handgrip is designed to fit onto the bottom of your camera and has a tripod thread for attaching it to a tripod, as well as a finger loop attachment for added stability.

Product Usage Instructions

Attaching the Handgrip

  1. Switch off the camera and any attached flash unit.

  2. Attach the handgrip to the bottom of the camera in such a way
    that the locking screw extends slightly into the tripod thread.

  3. Turn the locking toggle in a clockwise direction and tighten it slightly.

Wireless Charging of the Camera

  1. Switch off the camera and any attached flash unit.
  2. Position the camera with the handgrip attached on the charging station.

Note: Take note of the markings on the underside of the handgrip and ensure that you use a compatible charging station for wireless charging.

Important Safety Information
Before using the product, please read and follow all safety instructions provided in the user manual. It is important to handle the product with care to avoid injury or damage to property. Do not modify or attempt to repair the product yourself, and keep it away from water and extreme temperatures.

Regulatory Information
The Leica Wireless Charging Handgrip HG-DC1 is compliant with the essential requirements and other relevant provisions of Directive 2014/53/EU. The CE mark on the product documents compliance with the fundamental requirements of applicable EU guidelines. For FCC compliance, follow the attached installation instructions and use only shielded interface cables with ferrite core when connecting to computer or peripheral devices.

Disposal of Electrical and Electronic Equipment
When disposing of the product, please follow the local regulations for the disposal of electrical and electronic equipment to minimize the impact on the environment.

Technical Specifications

  • Designation: Leica HG-DC1
  • Rated voltage / rated power: 9.0 V DC/1.1 A
  • Product type: Handgrip for wireless charging
  • Order No.: 19530
  • Country of origin: China

SAFETY REMARKS

  • The battery must be removed from the camera or charger and must be replaced immediately in case of a strange smell, discoloration, deformation, overheating or leakage. Continued use of the battery may result in overheating, which can cause fire and/or explosion!
  • Keep the battery away from sources of heat in case of leakage or if you smell burning. Leaked fluid can catch fire!
  • The use of other chargers not approved by Leica Camera AG can cause damage to the batteries – and in extreme cases – cause serious or life-threatening injuries.
  • Keep batteries out of the reach of children. Batteries can cause suffocation when swallowed.
  • Always keep the handgrip contacts clean, and never short-circuit them.

FIRST AID

  • Battery fluid may cause blindness if it comes into contact with the eyes. Rinse the eyes thoroughly with clean water immediately. Avoid rubbing. Seek medical attention immediately.
  • Leaked battery fluid poses an injury hazard when it comes in contact with clothing or skin. Rinse the affected areas thoroughly with clean water.

GENERAL INFORMATION

  • New batteries must be activated by charging in the charger before first use.

  • Battery and charger heat up during the charging process. That is normal and not a malfunction. Rechargeable lithium-ion batteries generate power by way of internal chemical reactions. These reactions are influenced by ambient temperature and humidity. Do not expose the battery to extreme temperatures (high or low) for extended periods of time (e.g. in a parked car in the summer or winter) to ensure a maximum service life.

  • Always remove the battery if the camera will not be used for an extended period of time. Make sure to switch the camera off via the main switch before removing the battery. Leaving the battery in the camera will result in a deep discharge after a few weeks. Voltage levels will decrease significantly, as the camera uses a low idle current to maintain settings.
    Dispose of damaged batteries in accordance with the relevant regulations at an approved collection point for proper recycling.

  • The date of manufacture can be found on the battery. The date format is week/year.

  • Using the charger in the vicinity of broadcasting receivers may interfere with reception. Ensure a distance of at least 1m between the charger and the receiver.

  • When the charger is in use, it may emit a buzzing sound – that is normal and not a malfunction.

REGULATORY INFORMATION
The icons displayed on this product (incl. the accessories) have the following meaning:

∼Alternating current (AC)
Direct current (DC)
Class II devices (the product has a double-insulated design)

You will find the manufacturing date of your product on the stickers of the packaging.

The date format is year/week.

CE MARK
The CE mark on our products documents compliance with the fundamental requirements of

Declaration of Conformity (DoC)
Hereby, “Leica Camera AG” declares that this product is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU.
Customers can download a copy of the original DoC to our Radio

Equipment products from our DoC server:www.cert.leica- camera.com
Please contact Leica Camera AG, Am Leitz-Park 5, 35578 Wetzlar, Germany in case of any further questions applicable EU guidelines.

DISPOSAL OF ELECTRICAL AND ELECTRONIC EQUIPMENT
(Applies within the EU and for other European countries with active waste separation policies.)

This device contains electric and/or electronic components which must not be disposed of in general household waste. Instead, it should be disposed of at a recycling collection point provided by your local authority. This service is free of charge. Any standard or rechargeable batteries used in this device must be removed and disposed of separately in accordance with local regulations.
Please contact your local authorities, waste disposal collection point or the retailer, from whom you purchased the device for more information on correct waste disposal

Only charging stations that are certified for the respective country and only use frequencies that are permitted according to country regulations must be used.

For UK only:
Declaration of Conformity (DoC Hereby, “Leica Camera AG” declares that this product is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. Customers can download a copy of the original DoC to our Radio Equipment products from our DoC server: www.cert .leica-camera.com Please contact Leica Camera AG, Am Leitz-Park 5, 35578 Wetzlar, Germany in case of any further questions

Authorized representative in United Kingdom: LEICA CAMERA LIMITED 6-8 James Street, London, UK, W1U 1ED

PART DESIGNATIONS

Leica-HG-DC1-Wireless-Charging-Handgrip-01

  1. Handle part
  2. Locking screw
  3. Thread for finger loop attachment
  4.  Contact
  5. Locking toggle
  6. Tripod thread

APPLICATION
The camera is powered by a lithium-ion battery. This accessory allows inductive charging of the rechargeable battery (in conjunction with a compatible charging station). Take note of the markings on the underside of the handgrip!

ATTACHING THE HANDGRIP

  • Switch off the camera and any attached flash unit
  • Attach the handgrip in such a way that the locking screw extends slightly into the tripod thread on the bottom of the camera
  • Turn the locking toggle in clockwise direction and tighten it slightly

WIRELESS CHARGING OF THE CAMERA

  • Switch off the camera and any attached flash unit
  • Position the camera with the handgrip attached on the charging station
  • Flashing of the status LED on the camera (green, 2 s interval) signifies active charging.

Notes

  • Only charging stations that are approved for the respective country may be used. Only the frequencies that are permitted in the respective country may be used.
  • The charging process will only initiate when the camera is correctly positioned on the charging station.
  • Only inductive charging stations with a min. 10 W output can be used.
  • Make sure to unplug any attached HDMI and USB cables from the camera before charging.

TECHNICAL DATA

  • Designation
    Leica HG-DC1

  • Rated voltage / rated power
    9.0V DC/1.1A

  • Product type
    Handgrip for wireless charging

  • Charging frequency
    110kHz–205kHz

  • Operating conditions
    +0°C to +40°C

  • Order No.
    19530

  • Country of origin
    China

FOR US ONLY:
FCC Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Caution:
To assure continued compliance, follow the attached installation instructions and use only shielded interface cables with ferrite core when connecting to computer or peripheral devices. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

Declaration of Conformity
Trade Name: Leica
Type No.: HG-DC1
Responsible party/ Support contact: Leica Camera Inc.
500 Frank W. Burr Blvd., Suite 570
Teaneck, NJ 07666
Tel.: 1 800 222 0118
Fax: +1 201 995 1684
[email protected]

This device complies with Part 15 of the FCC Rules.

Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Keep the camera and handgrip contacts clean and easily accessible

In case the battery will not be charged, please check:

  • If a proper charging station is used and that camera is standing correctly on it.
  • Handgrip is connected correctly with the camera.
  • If malfunction still persists, please contact Leica

Customer Care: Tel.: +1 800 222 0118
Fax: +1 201 995 1684 / [email protected]

FOR CANADA ONLY:
CAN ICES-003 (B)/NMB-003(B)
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s license-exempt RSS(s).

Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Leica User Manuals

Related Manuals