MokerLink G482GS 48 Port Gigabit Series Switch User Manual

October 30, 2023
MokerLink

MokerLink G482GS 48 Port Gigabit Series Switch User Manual
MokerLink G482GS 48 Port Gigabit Series Switch

Product
 introduction

The 48 port gigabit PoE / Non-PoE series switches has simple and convenient installation and maintenance means and rich business characteristics to help users create a safe and reliable high-performance network. This series products can be widely used in data exchange fields such as home network, security monitoring and wireless networking.

Product Characteristic

  • PoE series switches support IEEE802.3af/at/bt standard, automatically detect and supply power for PoE devices.
  • Support power supply for PoE devices such as wireless access point (AP) and network monitoring camera through Cat 5 / Cat 6 Ethernet cable
  • Flow control mode: full duplex adopts IEEE 802.3x standard, half duplex adopts back pressure standard.
  • Support port auto flip(Auto MDI/MDIX).
  • Support port lightning protection (Level II lightning protection requirements).
  • Store and forward switching mechanism is adopted.

G482GS

4810/100/1000Mbps
RJ45
+
21000Mbps
SFP

Product
 Display

POE‑G482GS

4810/100/1000Mbps
PoE
+
21000Mbps
SFP
Product
 Display

POE‑G484GSM

4810/100/1000Mbps
PoE
+
41000Mbps
SFP
Product
 Display

Back
(For
G482GS)
Product
 Display

Back 
(For
POE‑G82GS
/
POE‑G484GSM)
Product
 Display

Indicator definition

Indicator Sate Description
Power indicator:PW on Power on
off Power off
Network indicator:1~48 orange on

1000M
off| No data transmission on the corresponding port
green| on| The corresponding port works at 10 / 100M
off| No data transmission on the corresponding port
SFP indicator:49~50| on| SFP on

  • One
 switch

  • One
 power
cord

  • A user manual and warranty card

  • Wall hanging lug

Login
 Management

This content is only applicable to managed type of products, please read this help information for the first application

Web Management

  1. Connect the device and PC, to ensure that the device initialization is complete.
  2. Configure the IP address of the PC to be in the same network segment as the switch default IP address.
  3. Enter “http://192.168.2.1” in the address bar of the opened PC browser, then press “enter” to the web management login interface, input the default user name “admin” and password “admin”, and press “enter”.

Console Port Management

  1. Connect the PC and the switch console port with the console cable.
  2. Start the terminal simulation software, create a connection, select a serial port, and set communication parameters in consistent with the default configuration of the switch’s console port, as listed below:

Transmission rate: 115200
Data bits: 8
Parity bit: None
Stop bits: 1

Connecting 
Equipment

Network Cable
Pls use Cat5 and above network cable.

Optical Fiber

  1. Optical fibers must be used with the optical modules.
  2. Fiber bending radius must not be less than 40mm.

Power Cable

  1. Distance between power cable and network cable should be more than 10cm.
  2. The AC power please use the local AC power cable.
  3. The DC power please pay attention to the positive and negative electrodes. Flow control mode: None

Technical
 parameter

Model G482GS POE‑G482GS
Product mame 48 Port Gigabit Ethernet Switch with 2 Port SFP 48 Port Gigabit

PoE Switch with 2 Port SFP
Fixed Port| 4810/100/1000Base-TX   Rj45 port21000M SFP| 4810/100/1000Base‑TX PoE port(Data/Power) 21000M SFP
PoE Ports| /| 1‑4 port supports IEEE802.3af/at/bt, max 90W 5‑48 port supports IEEE802.3af/at, max 30W
PoE Pin| /| IEEE802.3 af/at: 12+ 36‑IEEE802.3 af/at/poe++/bt: 12+ 45+  36‑ 78‑
PoE Power| /| Max 400W
Bandwidth| 128Gbps
Packet Forwarding| 74.40Mpps
MAC| 8K
Buffer| 4.1M
Transmission Distance| 10BASE‑T £ Cat3,4,5 UTP(¡250 meter)100BASE‑TX : Cat5 or later UTP(150 meter) 1000BASE-TX : Cat6 or later UTP(150 meter)SFP: 1000M single and multimode optical module withmaximum distance ≤ 120km (depending on the optical
LED Indicator| module))PW:Power LED 1‑48:PoE work indicator49‑50:SFP connection indicator Port:(Orange=PoE LED, Green=LAN Link LED)
Power| Built‑in 2x power AC100‑240Vac 50‑60Hz 60W| Built‑in power AC100‑240V 7.6A max 400W
Operating Temperature Humidity| -10 ‑ 55°C, 5% ‑ 90% RH Non coagulation
Storage Temperature Humidity| -40 – +75°C, 5% – 95% RH Non coagulation
Product /Packing sizeLWH| 440mm290mm45mm 515mm375mm95mm
N.W/G.Wkg| 4.4kg/5.2kg
Lightning Protection level| Rack‑mount (optional machine hanger spare parts)
Installation| 6KV 8/20us Ip30
Certificate| 3C ;CE mark, commercial;CE/LVD EN60950;FCC Part 15 Class B;RoHS;
Warranty| Whole device for 1 year(Accessories not included)

Technical
parameter (For
POE‑G484GS)

Model POE‑G484GSM
Product mame 48 Port Gigabit Managed PoE Switch with 4 Port SFP
Fixed Port 4810/100/1000Base-TX   PoE port41000M SFP1*console port
PoE Ports 1‑4 port supports IEEE802.3af/at/poe++/bt, max 90W PoE out 5‑48

port supports IEEE802.3af/at, max 30W/port, PoE out
PoE Pin| IEEE802.3 af/at: 12+ 36‑IEEE802.3 af/at/poe++/bt: 12+ 45+  36‑ 78‑
PoE Bridge| Max 600W
Bandwidth| 256Gbps
Packet Forwarding| 74.88Mpps
MAC| 16K
Buffer| 12M
Transmission Distance| 10BASE‑T £ Cat3,4,5 UTP(¡250 meter)100BASE‑TX : Cat5 or later UTP(150 meter) 1000BASE-TX : Cat6 or later UTP(150 meter)
LED Indicator| PWR: Power LED SYS: (System LED1~48 Port:(Link LED;1000M LED;PoE LED49~52:(SFP LED)
Power| Built‑in power AC   100‑240Vac 50‑60Hz 7.6A   max 600W
Operating Temperature Humidity| -10 – +55°C, 5% – 90% RH Non coagulation
Storage Temperature Humidity| -40 – +75°C, 5% – 95% RH Non coagulation
Product /Packing sizeLWH| 440mm290mm45mm 515mm375mm95mm
N.W/G.Wkg| 5.5kg/6.3kg
Lightning Protection level| Rack‑mount (optional machine hanger spare parts)
Installation| 6KV 8/20us Ip30
Certificate| 3C ;CE mark, commercial;CE/LVD EN60950;FCC Part 15 Class B;RoHS;
Warranty| Whole device for 1 year(Accessories not included)

Software 
parameter (For
POE‑G484GSM)

Network Protocol| IEEE 802.3xIEEE 802.3、 IEEE 802.3u、 IEEE 802.3ab、 IEEE 802.3z IEEE 802.3adIEEE 802.3q、 IEEE 802.3q/pIEEE 802.1w、 IEEE 802.1d、 IEEE 802.1S、 IEEE 802.1X
---|---
MAC| Support 16K MAC address,auto aging and learning
VLAN Configuration| Support port‑based VLAN Up to 4096 VLANsSupport Voice VLAN, can configure Qos for voice data 802.1Q
Spanning Tree| STP(Spanning tree protocol) RSTP(Rapid spanning tree protocol) MSTP(Rapid spanning tree protocol) EPPS(Ring network protocol) EAPS(Ring network protocol) 802.1x
Port Aggregation| Support 8 groups of aggregation, each group support up to 8 ports
Port Mirroring| Support many‑to‑one port mirroring
Loop Guard| Support loop protection, real‑time detection, quick alram, concise location, Intelligent blocking, automatic recovery
Port Isolation| Support downlink ports isolate from each other and communicate with uplink port as well
Flow Control| Half duplex based on Back pressure; Full duplex based on PAUSE frame
Speed Limitation| Bandwidth management based on port input and output
Multicast Control| IGMPv1/2/3 and MLDv1/2 Snooping GMRP protocol registrationMulticast address management, multicast VLAN, multicast routing port, static multicast address
DHCP| DHCP Snooping
Storm Suppression| Support unknown unicast, multicast , unknown multicast, broadcast type storm suppression;Storm suppression based on bandwidth adjustment and storm filtering
Security| Support User port+IP address+MAC address ACL based on IP, MACSupport security properties of number of MAC address based on port
QOS| 802.1p port queue priority algorithm Cos/Tos,QOS remarkWRR(Weighted Round Robin), weighted priority rotation algorithm WRR、 SP、 WFQ priority scheduling modes
Cable Sequence| Auto‑MDIX; auto detection on straight‑through and cross‑over cable
Negotiation Mode| Port support auto negotiation function(self‑negotiation transmission rate and duplex mode)
System maintenance| Upgrade package upload System log viewingWEB recovery factory configuration

Attentions

To avoid equipment damage and personal injury caused by improper use, please follow the precautions as below:

  • Keep the status of power-off during installation, and wear anti-static wrist to ensure good contact between anti-static wrist and skin to avoid the hidden danger. The switch can only work normally under the correct power supply. Please confirm that the power supply voltage is consistent with the voltage marked by the switch.
  • Before switch on, please make sure that it will not cause overload of the power circuit, so as not to affect the normal operation of the switch or even unnecessary damage. In order to avoid the danger of electric shock, do not open the shell up when the switch works, even in the case of no live current, do not open.
  • Before cleaning the switch, pull out the power plug. Do not wipe it by using wet fabrics or liquid.
  • Install device in the rack-mount regularly from top to bottom, incase of over-load installation.
  • Don’t place other heavy objects on the surface of the switch to avoid accidents.

Get 
help
or 
claim
 warranty
Visit
Here:
http://www.mokerlink.com/support/
or
Scan
 QR
 Code

Wuhan MokerLink Technology Co.,Ltd
Rm10,13/F,Main Building 7,Changhang Lanjing International,
No.116 Gaoxin Ave.,Hongshan Dist.,Wuhan,China
http://www.mokerlink.com
support@mokerlink.com

MokerLink Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals