MokerLink G482GS 48 Port Gigabit Series Switch User Manual
- October 30, 2023
- MokerLink
Table of Contents
MokerLink G482GS 48 Port Gigabit Series Switch User Manual
Product introduction
The 48 port gigabit PoE / Non-PoE series switches has simple and convenient installation and maintenance means and rich business characteristics to help users create a safe and reliable high-performance network. This series products can be widely used in data exchange fields such as home network, security monitoring and wireless networking.
Product Characteristic
- PoE series switches support IEEE802.3af/at/bt standard, automatically detect and supply power for PoE devices.
- Support power supply for PoE devices such as wireless access point (AP) and network monitoring camera through Cat 5 / Cat 6 Ethernet cable
- Flow control mode: full duplex adopts IEEE 802.3x standard, half duplex adopts back pressure standard.
- Support port auto flip(Auto MDI/MDIX).
- Support port lightning protection (Level II lightning protection requirements).
- Store and forward switching mechanism is adopted.
G482GS 4810/100/1000Mbps RJ45 + 21000Mbps SFP
POE‑G482GS
4810/100/1000Mbps
PoE
+
21000Mbps
SFP
POE‑G484GSM
4810/100/1000Mbps
PoE
+
41000Mbps
SFP
Back
(For
G482GS)
Back
(For
POE‑G82GS
/
POE‑G484GSM)
Indicator definition
Indicator | Sate | Description |
---|---|---|
Power indicator:PW | on | Power on |
off | Power off | |
Network indicator:1~48 | orange | on |
1000M
off| No data transmission on the corresponding port
green| on| The corresponding port works at 10 / 100M
off| No data transmission on the corresponding port
SFP indicator:49~50| on| SFP on
-
One switch
-
One power cord
-
A user manual and warranty card
-
Wall hanging lug
Login Management
This content is only applicable to managed type of products, please read this help information for the first application
Web Management
- Connect the device and PC, to ensure that the device initialization is complete.
- Configure the IP address of the PC to be in the same network segment as the switch default IP address.
- Enter “http://192.168.2.1” in the address bar of the opened PC browser, then press “enter” to the web management login interface, input the default user name “admin” and password “admin”, and press “enter”.
Console Port Management
- Connect the PC and the switch console port with the console cable.
- Start the terminal simulation software, create a connection, select a serial port, and set communication parameters in consistent with the default configuration of the switch’s console port, as listed below:
Transmission rate: 115200
Data bits: 8
Parity bit: None
Stop bits: 1
Connecting Equipment
Network Cable
Pls use Cat5 and above network cable.
Optical Fiber
- Optical fibers must be used with the optical modules.
- Fiber bending radius must not be less than 40mm.
Power Cable
- Distance between power cable and network cable should be more than 10cm.
- The AC power please use the local AC power cable.
- The DC power please pay attention to the positive and negative electrodes. Flow control mode: None
Technical parameter
Model | G482GS | POE‑G482GS |
---|---|---|
Product mame | 48 Port Gigabit Ethernet Switch with 2 Port SFP | 48 Port Gigabit |
PoE Switch with 2 Port SFP
Fixed Port| 4810/100/1000Base-TX Rj45 port21000M SFP|
4810/100/1000Base‑TX PoE port(Data/Power) 21000M SFP
PoE Ports| /| 1‑4 port supports IEEE802.3af/at/bt, max 90W 5‑48 port supports
IEEE802.3af/at, max 30W
PoE Pin| /| IEEE802.3 af/at: 12+ 36‑IEEE802.3 af/at/poe++/bt: 12+ 45+ 36‑ 78‑
PoE Power| /| Max 400W
Bandwidth| 128Gbps
Packet Forwarding| 74.40Mpps
MAC| 8K
Buffer| 4.1M
Transmission Distance| 10BASE‑T £ Cat3,4,5 UTP(¡250 meter)100BASE‑TX : Cat5 or
later UTP(150 meter) 1000BASE-TX : Cat6 or later UTP(150 meter)SFP: 1000M
single and multimode optical module withmaximum distance ≤ 120km (depending on
the optical
LED Indicator| module))PW:Power LED 1‑48:PoE work indicator49‑50:SFP
connection indicator Port:(Orange=PoE LED, Green=LAN Link LED)
Power| Built‑in 2x power AC100‑240Vac 50‑60Hz 60W| Built‑in power AC100‑240V
7.6A max 400W
Operating Temperature Humidity| -10 ‑ 55°C, 5% ‑ 90% RH Non coagulation
Storage Temperature Humidity| -40 – +75°C, 5% – 95% RH Non coagulation
Product /Packing sizeLWH| 440mm290mm45mm 515mm375mm95mm
N.W/G.Wkg| 4.4kg/5.2kg
Lightning Protection level| Rack‑mount (optional machine hanger spare parts)
Installation| 6KV 8/20us Ip30
Certificate| 3C ;CE mark, commercial;CE/LVD EN60950;FCC Part 15 Class B;RoHS;
Warranty| Whole device for 1 year(Accessories not included)
Technical parameter (For POE‑G484GS)
Model | POE‑G484GSM |
---|---|
Product mame | 48 Port Gigabit Managed PoE Switch with 4 Port SFP |
Fixed Port | 4810/100/1000Base-TX PoE port41000M SFP1*console port |
PoE Ports | 1‑4 port supports IEEE802.3af/at/poe++/bt, max 90W PoE out 5‑48 |
port supports IEEE802.3af/at, max 30W/port, PoE out
PoE Pin| IEEE802.3 af/at: 12+ 36‑IEEE802.3 af/at/poe++/bt: 12+ 45+ 36‑ 78‑
PoE Bridge| Max 600W
Bandwidth| 256Gbps
Packet Forwarding| 74.88Mpps
MAC| 16K
Buffer| 12M
Transmission Distance| 10BASE‑T £ Cat3,4,5 UTP(¡250 meter)100BASE‑TX : Cat5 or
later UTP(150 meter) 1000BASE-TX : Cat6 or later UTP(150 meter)
LED Indicator| PWR: Power LED SYS: (System LED1~48 Port:(Link LED;1000M
LED;PoE LED49~52:(SFP LED)
Power| Built‑in power AC 100‑240Vac 50‑60Hz 7.6A max 600W
Operating Temperature Humidity| -10 – +55°C, 5% – 90% RH Non coagulation
Storage Temperature Humidity| -40 – +75°C, 5% – 95% RH Non coagulation
Product /Packing sizeLWH| 440mm290mm45mm 515mm375mm95mm
N.W/G.Wkg| 5.5kg/6.3kg
Lightning Protection level| Rack‑mount (optional machine hanger spare parts)
Installation| 6KV 8/20us Ip30
Certificate| 3C ;CE mark, commercial;CE/LVD EN60950;FCC Part 15 Class B;RoHS;
Warranty| Whole device for 1 year(Accessories not included)
Software parameter (For POE‑G484GSM)
Network Protocol| IEEE 802.3xIEEE 802.3、 IEEE 802.3u、 IEEE 802.3ab、 IEEE
802.3z IEEE 802.3adIEEE 802.3q、 IEEE 802.3q/pIEEE 802.1w、 IEEE 802.1d、 IEEE
802.1S、 IEEE 802.1X
---|---
MAC| Support 16K MAC address,auto aging and learning
VLAN Configuration| Support port‑based VLAN Up to 4096 VLANsSupport Voice
VLAN, can configure Qos for voice data 802.1Q
Spanning Tree| STP(Spanning tree protocol) RSTP(Rapid spanning tree protocol)
MSTP(Rapid spanning tree protocol) EPPS(Ring network protocol) EAPS(Ring
network protocol) 802.1x
Port Aggregation| Support 8 groups of aggregation, each group support up to 8
ports
Port Mirroring| Support many‑to‑one port mirroring
Loop Guard| Support loop protection, real‑time detection, quick alram, concise
location, Intelligent blocking, automatic recovery
Port Isolation| Support downlink ports isolate from each other and communicate
with uplink port as well
Flow Control| Half duplex based on Back pressure; Full duplex based on PAUSE
frame
Speed Limitation| Bandwidth management based on port input and output
Multicast Control| IGMPv1/2/3 and MLDv1/2 Snooping GMRP protocol
registrationMulticast address management, multicast VLAN, multicast routing
port, static multicast address
DHCP| DHCP Snooping
Storm Suppression| Support unknown unicast, multicast , unknown multicast,
broadcast type storm suppression;Storm suppression based on bandwidth
adjustment and storm filtering
Security| Support User port+IP address+MAC address ACL based on IP, MACSupport
security properties of number of MAC address based on port
QOS| 802.1p port queue priority algorithm Cos/Tos,QOS remarkWRR(Weighted Round
Robin), weighted priority rotation algorithm WRR、 SP、 WFQ priority scheduling
modes
Cable Sequence| Auto‑MDIX; auto detection on straight‑through and cross‑over
cable
Negotiation Mode| Port support auto negotiation function(self‑negotiation
transmission rate and duplex mode)
System maintenance| Upgrade package upload System log viewingWEB recovery
factory configuration
Attentions
To avoid equipment damage and personal injury caused by improper use, please follow the precautions as below:
- Keep the status of power-off during installation, and wear anti-static wrist to ensure good contact between anti-static wrist and skin to avoid the hidden danger. The switch can only work normally under the correct power supply. Please confirm that the power supply voltage is consistent with the voltage marked by the switch.
- Before switch on, please make sure that it will not cause overload of the power circuit, so as not to affect the normal operation of the switch or even unnecessary damage. In order to avoid the danger of electric shock, do not open the shell up when the switch works, even in the case of no live current, do not open.
- Before cleaning the switch, pull out the power plug. Do not wipe it by using wet fabrics or liquid.
- Install device in the rack-mount regularly from top to bottom, incase of over-load installation.
- Don’t place other heavy objects on the surface of the switch to avoid accidents.
Get
help
or
claim
warranty
Visit
Here:
http://www.mokerlink.com/support/
or
Scan
QR
Code
Wuhan MokerLink Technology Co.,Ltd
Rm10,13/F,Main Building 7,Changhang Lanjing International,
No.116 Gaoxin Ave.,Hongshan Dist.,Wuhan,China
http://www.mokerlink.com
support@mokerlink.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>