MokerLink 16 Port PoE Switch User Guide

June 8, 2024
MokerLink

Quick Start Guide
Ethernet Switch

MokerLink 16 Port PoE Switch

Description

The products described in this manual, including but not limited to the illustrated products, please refer to the actual product purchased. If any changes on product apperance, Please refer to the official product information.

Packing List

  • Switch(specific model see the product label for more details)
  • Power cable(the default is pluggable or a power cable with built-in power module)
  • Power adapter(use for some external power products)
  • Console cable, configurable disc(use for managed products)
  • Brackets, screw(rack type standard, desktop type optional)
  • User manual

Switch Installation

Switches support a variety of installation methods, desktop, wall mount,  rack mount, please install according to the actual environmental requirements.

Mounting Ear Installation

MokerLink 16 Port PoE Switch - Fig 1

Rack Mount Installation

MokerLink 16 Port PoE Switch - Fig 2

Connecting Equipment

Network Cable

  1. When the RJ45 port is on 2.5GE rate, use Cat5E and above network cable.
  2. When the RJ45 port is on 5GE rate, a shielded network cable of Cat5E and above specifications is required, the unshielded network cable is not recommended.
  3. When the RJ45 port is on 10GE rate, shielded network cable of Cat6A and above specifications is required.

Optical Fiber

  1. Optical fibers must be used with the optical modules.
  2. Fiber bending radius must not be less than 40mm.

Power Cable

  1. Distance between power cable and network cable should be more than 10cm.
  2. The AC power please use the local AC power cable.
  3. The DC power please pay attention to the positive and negative electrodes.

Login Management

Thís content is only applicable to managed type of products, please read this help information for the first application

Web Management

  1. Connect the device and PC, to ensure that the device initialization is complete.
  2. Configure the IP address of the PC to be in the same network segment as the switch default IP address.
  3. Enter “http://192.168.2.1” in the address bar of the opened PC browser, then press “enter” to the web management login interface, input the default user name “admin” and password “admin”, and press “enter”.

Console Port Management

  1. Connect the PC and the switch console port with the console cable.
  2. Start the terminal simulation software, create a connection, select a serial port, and set communication parameters in consistent with the default configuration of the switch’s console port, as listed below:

Transmission rate: 115200
Dáta bits: 8
Parity bit: None
Stop bits: 1
Flow control mode: None

PoE Powered Function

※ Thís function is applicable to PoE switches, not applicable to non-PoE switches
Standard PoE Supply

MokerLink 16 Port PoE Switch - Fig 3

Passive PoE Power Supply

MokerLink 16 Port PoE Switch - Fig 4

  1. Standard PoE power supply includes: protocol detection, power pin sequence detection, power output, abnormal protection, Link abnormal monitoring.

  2. The PoE power supply protocol includes: IEEE802.3af(15.4W), IEEE802.3at(30W), IEEE802.3bt(90W).

  3. The standard PoE power pin sequence is 1,2+/3,6-, and the passive PoE power pin sequence is 4,5+/7,8-.

  4. The standard PoE switches can automatically detect and supply power to the PDs that meet the standard, non-PoE devices are not powered and only transmit data.

  5. Passive PoE switches use mandatory power supply mode, non-PoE powered devices may be burned out, please use with caution.

  6. 24V PoE switches have both low-voltage power supply and PD detection technology, which can provide 24V voltage on 4,5/7,8 pin, even if it is connected to nontandard equipment it will not burn out.

Indicator Definition

Indicator Definition State Description
PWR Power Indicator Light on / Light off Powered / Abnormal
SYS System Indicator Light on / Flash System Normal / Starting
PoE PoE Indicator Light on / Light off PoE Powered / No Power
1000M Link Rate Light on / Light off Gigabit / 10/100M
100M Link Rate Light on / Light off 100M / Link Disconnect
Link/ACT Link & Data Light on / Flash Link is Normal
Mode/SW Dial Switch Light on/Flash/Off VLAN/Extend/Default
Loop Loop Alarm Light on Port Loop

States Definition

Function Definition State Description
VLAN Port Isolation Light on Designated port can not communicate with each

other
Extend| Link Extension| Flash| Designated port link exteded to 250 meters
Default| Normal Mode| Light off| All ports can communicate with each other
Reset| Reset Button| Flash| Short press restart, long press more than 5s reset cofiguration
Al PoE| PoE Watchdog| /| PDs crashed and restart automatically
MAX| Power Display Indicator| Green
Yellow
Orange
Red| PoE power output 25%
PoE power output 50%
PoE power output 75%
PoE power output 75%

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>