ACTIVE VPC-3 Vent Pipe Cap Installation Guide

October 30, 2023
ACTIVE

Installation Instructions

Vent Pipe Cap Model: VPC-3 Diameter: 3″

VPC-3 Vent Pipe Cap

Flashing Detail & Instructions

  1. Slide the Vent Pipe Cap over the existing pipe.
  2. Observe the screws located on top of the vent. Use this as a pattern to attach the vent to the pipe.
  3. To secure the vent, attach the vent to the pipe using a #8 self-tapping sheet metal screw.
  4. Total number of screws needed = 3
  5. Recommended installation screw: #8 x 1/2″ Sheet Metal Screw
  6. Screws not included.
  • All Aluminum Construction, Thickness = 0.025″ [0.635 mm]

Active Ventilation Products, Inc.
Website: roofvents.com Email: sales@roofvents.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ACTIVE User Manuals

Related Manuals