Laserliner 080.855A Laser Range-Master T7 Rangefinder Reading Range Instruction Manual

June 4, 2024
Laserliner

Laserliner 080.855A Laser Range-Master T7 Rangefinder Reading Range

Laserliner-080.855A-Laser-Range-Master-T7-Rangefinder-Reading-Range-
product

Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and if the laser device is passed on, this document must be passed on with it.

Dimension

Laserliner-080.855A-Laser-Range-Master-T7-Rangefinder-Reading-Range-
fig-1 Laserliner-080
.855A-Laser-Range-Master-T7-Rangefinder-Reading-Range-
fig-2 Laserliner-080
.855A-Laser-Range-Master-T7-Rangefinder-Reading-Range-
fig-3

Function / Application
Compact laser distance meter for measuring length, area and volume indoors

General safety instructions

  • The device must only be used in accordance with its intended purpose and within the scope of the specifications.
  • The measuring tools and accessories are not toys. Keep out of reach of children.
  • Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
  • Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
  • The device must no longer be used if one or more of its functions fail or the battery charge is weak.
  • When using the device outdoors, make sure that the weather conditions are appropriate and/or that suitable protection measures are taken.
  • Please ensure compliance with the safety regulations set out by local and national authorities with regard to the correct and proper use of the device.
Safety instructions

Using class 2 lasers

Laser radiation!
Do not stare into the beam!Class 2 laser < 1 mW · 635 nm EN 60825-1:2014/AC:2017

  • Attention: Do not look into the direct or reflected beam.
  • Do not point the laser beam towards persons.
  • If a person‘s eyes are exposed to class 2 laser radiation, they should shut their eyes and immediately move away from the beam.
  • Tampering with (making changes to) the laser device is not permitted.
  • Under no circumstances should optical instruments (magnifying glass, microscope, binoculars)

Dealing with electromagnetic radiation

  • The measuring device complies with electromagnetic compatibility regulations and limit values in accordance with EMC-Directive 2014/30/EU.
  • Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
  • The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.
Inserting batteries

Open the battery compartment and insert batteries (3 x typ AAA) according to the symbols. Be sure to pay attention to polarity.Laserliner-080.855A-Laser-
Range-Master-T7-Rangefinder-Reading-Range-fig-4

DISPLAY

Laserliner-080.855A-Laser-Range-Master-T7-Rangefinder-Reading-
Range-fig-5

  • a Measured value memory
  • b Unit of measure m / ft / inch /
  • c Measurement point (reference) front / thread / rear
  • d Set measuring level
  • e Battery symbol
  • f Set measuring function
  • g 1st / 2nd and 3rd length measurement
  • h 4th length measurement
  • i Measuring functions
  • j Addition function
  • k Subtraction function

KEYPAD

  1. Measure min/max continuous measurement
  2. ON / OFF

Switch on, measure and switch off

Laserliner-080.855A-Laser-Range-Master-T7-Rangefinder-Reading-Range-
fig-7

Change unit of measure:
m / ft / inch / Laserliner-080.855A-Laser-Range-Master-T7-Rangefinder-
Reading-Range-fig-8

Change measurement point (reference):
front / thread / rearLaserliner-080.855A-Laser-Range-Master-T7
-Rangefinder-Reading-Range-fig-9

Change measurement function:
length / area / volume / Pythagoras 1 / Pythagoras 2 / Pythagoras 3Laserliner-080.855A-Laser-Range-Master-T7-Rangefinder-Reading-Range-
fig-10

Length measurement:Laserliner-080.855A-Laser-Range-Master-T7-Rangefinder-
Reading-Range-fig-11

min/max continuous measurement:Laserliner-080.855A-Laser-Range-Master-T7
-Rangefinder-Reading-Range-fig-12

The LC display shows the max value, the min value, and the current value.

In the area measurement, volume measurement, and Pythagoras 1 to 3 functions, the laser will switch off if left idle for a short time and must be switched on again by pressing button 1 in order to continue the measurement.

Area measurement

Laserliner-080.855A-Laser-Range-Master-T7-Rangefinder-Reading-Range-
fig-13

Volume measurementLaserliner-080.855A-Laser-Range-Master-T7-Rangefinder-
Reading-Range-fig-14

Function

Pythagoras function 1:Laserliner-080.855A-Laser-Range-Master-T7
-Rangefinder-Reading-Range-fig-15

Pythagoras function 2:Laserliner-080.855A-Laser-Range-Master-T7
-Rangefinder-Reading-Range-fig-16

Pythagoras function 3:Laserliner-080.855A-Laser-Range-Master-T7
-Rangefinder-Reading-Range-fig-17

Addition and subtraction of lengths:

  1. Length measurement
  2. Addition or subtraction selection
  3. Add length measurementLaserliner-080.855A-Laser-Range-Master-T7-Rangefinder-Reading-Range-fig-18

Area calculation:

  1. Area measurement
  2. Addition or subtraction selection
  3. Add area measurementLaserliner-080.855A-Laser-Range-Master-T7-Rangefinder-Reading-Range-fig-19

Volume calculation

  1. Volume measurement
  2. Addition or subtraction selection
  3. Add volume measurementLaserliner-080.855A-Laser-Range-Master-T7-Rangefinder-Reading-Range-fig-20

Memory function:
The device has 30 storage locations.Laserliner-080.855A-Laser-Range-
Master-T7-Rangefinder-Reading-Range-fig-21

Important notices

  • The laser points to the location that will be measured. No objects may get into the laser‘s line of measurement.
  • The device compensates the measurement for different room temperatures. Therefore allows the device a brief adaptation period when changing locations with large temperature differences.
  • The device is only conditionally useable in outdoor areas and cannot be used in strong sunlight.
  • The measurement results of outdoor measurements may be influenced or falsified by rain, fog and snow.
  • In unfavorable conditions, e.g. with poorly reflecting surfaces, the maximum deviation may be greater than 3 mm.
  • Carpeting, upholstery or curtains will not reflect the laser optimally. Measure to flat surfaces.
  • Measurements made through glass (window panes) can falsify measurement results.
  • An energy-saving function switches the device off automatically.
  • Clean with a soft cloth. Water may not be allowed to penetrate the housing.

Error codes

  • 204 Calculation error
  • 208 Excess current (please contact your retailer)
  • 220 Replace the battery
  • 252 Temperature is too high
  • 253 Temperature is too low
  • 255 Received signal too weak or measuring time too long
  • 256 Received signal too strong
  • 251 Outside the measuring range
  • 500 Hardware fault (If the symbol stays on after switching the device off and on, please contact your retailer.)

Information on maintenance and care

Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Remove the battery(ies) before storing for longer periods. Store the device in a clean and dry place.

Calibration

The measuring device should be calibrated and tested on a regular basis to ensure it is accurate and working properly. We recommend carrying out calibration once a year. If necessary, contact your distributor or the UMAREX- LASER LINER service department.

Technical Data

Technical Data (Subject to technical changes without notice. Rev22W03)|  |
---|---|---
Distance measurement|
 |
Precision (typical)*| ± 2 mm|
Measurement range (inside) **| 0,2 m – 70 m|  |


Laser class

| 2 / < 1 mW

(EN 60825-1:2014/AC:2017)

|
Laser wavelength| 635 nm|



Operating conditions

| -10°C…40°C, Max. humidity 20…85% rH, no condensation, Max. working altitude 2000 m above sea level|
Storage conditions| -20°C … 70°C, max. humidity 80% rH|
Automatic switch-off| 30 sec laser / 3 min device|
Power supply| 3 x 1,5V LR03 (AAA)|
Dimensions (W x H x D)| 49 x 115 x 26 mm|
Weight| 145 g (incl. batteries)|

  • measuring distance up to 10 m with a strongly reflective target surface and at room temperature. The measurement deviation may increase by± 0.2 mm/m for greater distances and under unfavorable measuring conditions such as strong sunlight or weakly reflective target surfaces.
  • at max. 5000 lux

EU and UK directives and disposal

This device complies with all necessary standards for the free movement of goods within the EU and the UK. This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment. Further safety and supplementary notices at: https://packd.li/ll/ada/in.

SERVICE

Umarex GmbH & Co. KG

Laserliner

  • Möhnestraße 149, 59755 Arnsberg, Germany Tel.: +49 2932 638-300, Fax: +49 2932 638-333 info@packd.li/ll/ada/in.
  • Umarex GmbH & Co. KG Donnerfeld 2 59757 Arnsberg, Germany
  • Tel.: +49 2932 638-300, Fax: -333 www.packd.li/ll/ada/in.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Laserliner User Manuals

Related Manuals