SJE RHOMBUS SJE115 Control Panel Instructions

June 1, 2024
SJE RHOMBUS

SJE RHOMBUS SJE115 Control Panel

SJE-RHOMBUS-SJE115-Control-Panel-product

Specifications

  • Enclosure Size: 10 x 8 x 4 inches (25 x 20 x 10 cm)
  • Enclosure Material: NEMA 4X ultraviolet stabilized thermoplastic
  • Power: Single Phase
  • Control: Simplex Timed Dosing Pump Control

Product Usage Instructions

Components Overview:

The TD Control Panel includes various components for controlling the dosing pump, such as an enclosure, motor contactor, programmable timer, circuit breaker, alarm horn, and more.

Installation:

  1. Ensure the power source is disconnected before installation.
  2. Mount the TD Control Panel in a suitable location indoors or outdoors.
  3. Connect the necessary electrical lines to the appropriate terminal blocks.

Programming the Timer:

The programmable timer allows setting on and off times from .1 seconds to 10 hours. Follow these steps to program the timer:

  1. Adjust the timer controls to set the desired on and off times.
  2. Refer to the Timer Installation Label for specific instructions.

Manual Pump Control:

Use the HOA switch for manual pump control when needed.

Frequently Asked Questions

  • Q: What is the purpose of the alarm horn?
    • A: The alarm horn provides an audio warning of alarm conditions with an 83 to 85 decibel rating.
  • Q: How to silence the alarm horn?
    • A: Use the Exterior Alarm Test/Normal/Silence switch to silence the alarm horn in an alarm condition. The horn will automatically reset once the alarm condition is cleared.

Product Information

The Model TD control panel provides a reliable means of controlling one single phase pump in onsite septic installations. A programmable timer activates a magnetic motor contactor to turn the pump on and off. A low level cutout float overrides the timer to prevent the pump from running dry. An alarm float activates the audio/visual alarm system indicating a high liquid level. Common applications include sand filter systems, pressure distribution systems, mound systems, or any application requiring a timed dose. This panel is available with optional EZconnex® float connection system.

COMPONENTS

  1. Enclosure measures 10 x 8 x 4 inches (25 x 20 x 10 cm) NEMA 4X (ultraviolet stabilized thermoplastic) for indoor or outdoor use
  2. Magnetic motor contactor controls pump by switching electrical lines
  3. HOA switch for manual pump control
  4. Control fuse
  5. Alarm fuse
  6. Float switch terminal block
  7. Incoming power terminal block
  8. A programmable timer with separate variable controls allows for setting the on and off times from .1 seconds to 10 hours
  9. Circuit breaker provides pump disconnect and branch circuit protection
  10. Spare fuse
  11. Backplate label includes diagram of float, pump, and power connections
  12. Ground lug
  13. Red LED beacon provides 360° visual check of alarm condition
  14. The alarm horn provides audio warning of alarm conditions (83 to 85 decibel rating) (Not shown)
  15. Exterior alarm Test/Normal/Silence switch allows horn and light to be tested and horn to be silenced in an alarm condition; alarm automatically resets once alarm condition is cleared (Not shown)
  16. Horn silence relay (No shown – mounted under bracket)SJE-RHOMBUS-SJE115-Control-Panel-fig \(1\)

Note: Other options available.

Note: Timer Installation Label and Pump/Float Switch Installation Specification Label are located inside the panel on enclosure cover.

MODEL TD – Single phase, simplex timed dosing pump control.

Timed Dosing

SJE-RHOMBUS-SJE115-Control-Panel-fig
\(2\) SJE-RHOMBUS-SJE115-Control-Panel-fig
\(3\)

PRICING WORKSHEET

  • Model TD Base Price
  • Alarm Package
  • Enclosure Rating
  • Starting Device
  • Pump Full Load Amps
  • Float Switch Application
  • Total Options
  • TOTAL LIST PRICE

DESCRIPTION

| OPTIONS| DESCRIPTION
---|---|---
| 1F| Door Mounted Alarm Indicator with Horn and Test/Normal/

Silence Switch (must select “0” for ALARM PACKAGE )

| 4B| Red Redundant Off Indicator & Alarm

(must also select Option 4D if floats are required)

| 4D| Redundant Off Float
| 4E| Redundant Off Float, Alarm Activation (20’ SJE SignalMaster® SPDT)
| 6A| Auxiliary Alarm Contact, Form A
| 8A| Elapsed Time Meter
| 8C| Event (Cycle) Counter
✓| 10E| Lockable Latch NEMA 4X (included as standard)
| 10K| Anti-condensation Heater

| OPTIONS| DESCRIPTION
---|---|---
| 16A| 10’ Cord in Lieu of 20’ Cord (per float)
| 16B| 15’ Cord in Lieu of 20’ Cord (per float)
| 16C| 30’ Cord in Lieu of 20’ Cord (per float)
| 16D| 40’ Cord in Lieu of 20’ Cord (per float)
| 17W| SJE MilliAmpMaster™ Wide-Angle / Pipe Clamp
| 18A| Timer Override Float
| 19X| Door Mounted Pump Run Indicator
| 33U| EZconnex® 3-Port, 50’, with 10’ Floats (3) / Pipe Clamp
| 35U| EZconnex® 4-Port, 50’, with 10’ Floats (4) / Pipe Clamp
| 36U| EZconnex® 3-Port, 50’, with 10’ Floats (2) / Pipe Clamp, Sealing Plug

Contact

9500078K Rev 07/23 © 2020 SJE, Inc. All Rights Reserved. SJE Rhombus is a trademark of SJE, Inc.

California Prop 65 requires the following:

WARNING-Cancer and Reproductive Harm –