GAZELLE G9504 Red Laser Distance Meter 100m
Safety Information
Before using the meter for the first time, please read the safety information and operating instructions carefully.
- Use the meter only as specified in this manual. Otherwise, it may cause damage to the meter, affect measurement accuracy and result in personal injury.
- Do not disassemble or repair the meter without authorization. Do not refit or change the performance of the laser transmitter illegally. Please keep the meter properly, do not place it where children can reach it, and avoid use by irrelevant personnel.
- Do not irradiate the laser at eyes and other parts of the body , and on the surface of highly reflective objects.
- The electromagnetic radiation of the meter may cause interference to other equipment. Please do not use the meter near airplanes, medical equipment or in flammable and explosive environments.
- The replaced batteries and discarded meters cannot be disposed of together with domestic garbage. Please dispose of them in accordance with relevant national or local laws and regulations.
- If the meter has any quality problems, or if users have any questions about the use of the meter, please contact the local dealer or manufacturer in time.
Product Introduction
Display
Batteries
- Open the battery door on the back of the meter, install the battery according to the polarity instructions, and close the battery door.
- The meter can only use 1.5V AAA alkaline batteries.
- When the meter is not used for a long time, please take out the battery to prevent it from corroding the meter’s main body.
Power On and Function Settings
-
Power On/Off
In the shutdown state, press, the meter and the laser will be started at the same time.
In the power-on state, press and hold for 3 seconds to turn off the meter. If no operation is performed within 150 seconds, the meter will automatically shut down. -
Unit Settings
Long press to enter the unit setting state and the current unit can be reset. The default unit of the meter is 0.000m. There are 6 optional units.
Measurement units:
Length | Area | Volume |
---|---|---|
0.000 m | 0.000 m’ | 0.000 m’ |
0.00 m | 0.00 m’ | 0.00 m’ |
0.0 in 0.00 ft’ I o.oo ft’
0 1/16 in| 0.00 ft’| 0.00 ft3
0’00” 1/16| 0.00 ft’| 0.00 ft3
0.00 ft| 0.00 ft’| 0.00 ft3
-
Measurement Reference Settings
Short press to measure from front or end. The default setting is end measurement. -
Backlight
The backlight is automatically turned on and off. It will tum on for 15 seconds when any button is pressed. The backlight will automatically turn off if there is no operation after 15 seconds to save power. -
Sound
Long press ( to turn on or off the sound of the beeper. -
Self-Calibration
Self-calibration function can ensure the measurement accuracy. Calibration method: In the shutdown state, press and hold ‘:”, and then short press to turn on the meter. When the screen shows ‘ CRL’ with a flashing number at the bottom, the meter enters the self-calibration mode. At this time, users can press+ ;i to calibrate values according to the error of the meter.
Calibration range: -9~9mm
Examples: The actual distance is 3.780m.
If the measured value is 3. 778m, which is 2mm smaller than the actual value, press + to increase the calibration value by 2mm.
If the measured value is 3. 783m, which is 3mm larger than the actual value, press j to lower the calibration value by 3mm.
After adjustment, press to save the calibration results.
Measurement Modes
-
Single Measurement
While the meter is on, press to transmit the laser Press #,\ again to make the distance measurement. The measurement results will show on the primary display. -
Continuous Measurement
While the meter is on, long press to enter the continuous measurement state. The maximum and minimum values during the measurement will show on the secondary display. The measurement results will show on the primary display. Short press to exit the continuous measurement. -
Area Measurement
Press FUNC 1x. The D symbol will appear on the display and one side of the rectangle will flash.
Press to make the first measurement (length).
Press again to make the second measurement (width).
The meter will automatically calculate the area, and the result will show on the primary display. The length and width will show on the secondary display. During the measurement process, press to clear the measurement result and re- measure.
Press to exit the area measurement and enter the length measurement mode. -
Volume Measurement
Press FUNC 2x. The Ell symbol will appear on the display.
Press to make the first measurement (length).
Press again to make the second measurement (width).
Press again to make the third measurement (height).
The meter will automatically calculate the volume, and the result will show on the primary display. The length, width and height will show on the secondary display.
During the measurement process, press to clear the measurement result and re- measure.
Press to exit the volume measurement and enter the length measurement mode. -
Indirect Measurement
The meter has four modes that use the Pythagorean theorem to measure the distance of one side of a triangle, which is convenient for users to perform indirect measurement in a complex environment.
Addition/Subtraction
The single distance measurement values can be added or subtracted. After
getting the result when taking a single distance measurement, press + ii to
enter the addition/subtraction mode.
Short press +, the “+” symbol will show on the primary display, and then it
will enter the addition mode. The addition value of the last and the current
measurement values will show on the display.
Short press ii, the ” – ” symbol will show on the primary display, and then it
will enter the subtraction mode. The subtraction value of the last and the
current measurement values will show on the display.
Not only the distance can be added and subtracted, but also the area and the
volume.
Area addition: Measure the first area and get the result, as shown in Figure 1 below. Then press It to measure the second area and get the result, as shown in Figure 2 below, and a plus sign will be displayed in the lower left corner. Finally, press to get the result of adding these two areas, as shown in Figure 3. The addition and subtraction of volume is similar to it.
Data Storage
If the current data is valid when measuring, press and hold II for 3 seconds,
and the data will be automatically stored in the meter memory. In the area,
volume and indirect measurement modes, the data can also be stored after all
the tests are over. At this lime, the meter will store the complete
measurement record under this mode.
View/Delete Data
Short press II to query the stored data. Press + to scroll forwards, and press
‘i to scroll backwards. When viewing data, short press c: to delete the
current record, and long press’• to delete all records. Press It or to exit.
Error Codes
Code | Cause | Resolution |
---|
Err
| Out of distance measurement range| Use the meter in designated environments.
Err1
| Signal too weak| Measure the target point with strong reflection ability.
Err2
| Signal too strong| Measure the target point with weak reflection ability.
Err3| Battery power too low| Replace batteries.
Err4| Out of operating temperature range| Use the meter within the range.
Err5
| Pythagorean measurement error| Re-measure to ensure that the hypotenuse is longer than the leg.
Specifications
Items | G9504 |
---|---|
Measurement range | 100m |
Measurement accuracy | ±(2mm+5*1o·5 D) |
Continuous measurement | |
Area/volume measurement | |
Pythagorean measurement | |
Addition/subtraction | |
Area/volume addition/subtraction | |
Max/min | |
Self-calibration | |
Laser class | Class II |
Laser type | Class 2 630-670nm, 1mW |
Data storage | 99 groups |
Auto laser off | 20s (single measurement) |
Auto power off | About150s |
Battery life | Up to 8000 measurements |
Sound prompt | |
Storage temperature | – 2o·c – 5o·c |
Operating temperature | o·c – 4o·c |
Storage humidity | 20%- B0¾RH |
Batteries | 1.5V 2xAAA |
Product size | 112x50x25mm |
- “d” means actual distance.
- Under harsh environments, such as excessive sunlight and ambient temperature fluctuations, weak reflection on reflective surfaces, and insufficient battery power, the measurement results will have errors. At this time, using the target reflector can improve the measurement accuracy.
Maintenance
Do not place the meter in a high temperature and humidity environment for a
long time. When not using the meter for a long time, please take out the
battery and put the meter in the carrying bag, and store it in a cool and dry
place.
Remove dirt with a moist, soft cloth. Do not use aggressive detergents or
solutions. The laser window and focusing lens can be wiped according to the
method of wiping the optical device.
Packing List
All accessories are shown in the table below.
Items Accessories Quantity
1 Meter 1
2 Carrying bag 1
3 AAA batteries 2
4 User manual 1
5 Gift box 1
Gazelle Industrial Co.
sales@gazelleindustrial.com
support@gazelleindustrial.com
www.gazelleindustrial.com
Manufactured by an ISO Certified Company
Made in China