NOVY 7836 Wall Mounted Hood Instruction Manual

June 10, 2024
NOVY

NOVY 7836 Wall Mounted Hood

NOVY-7836-Wall-Mounted-Hood-product

Product Information

The Novy Vision is a kitchen appliance that is designed to extract cooking fumes and odors from the kitchen. The model numbers for this product are 7836, 7838, 7839, 7848, 7849, 7856, 7858, and 7859. This product is intended for household use only and is not meant for commercial or industrial use. The product comes with a separate user manual that provides instructions on how to use the appliance safely and effectively. The installation of the product should only be done by a certified professional.

Product Usage Instructions

  • Before installation, please ensure that the product is not damaged and all the necessary materials needed for installation are included. The vet filters are already located within the product. Use gloves while installing the product as some metal parts may have sharp edges that could cause injury.
  • To ensure that cooking fumes are optimally absorbed, the product or the structure in which it is installed must cover the cooktop. If the installation manual of a gas cooktop indicates a different distance, it is recommended to follow the greater distance mentioned. The cooktop should not be larger than the product or the structure in which it is installed for optimal performance.
  • Please note that Novy is not liable for any damages caused by incorrect installation, incorrect connection, incorrect use, or incorrect operation of the product. It is recommended to hire a professional installer and follow all instructions provided in the manual for safe and effective use of the product.

SAFETY AND ASSEMBLY REGULATIONS

  • Further information on Novy products, accessories and services may be found on the internet: www.novy.co.uk

  • These are the installation instructions for the appliance as shown on the front. The directions for use are in a separate booklet supplied with the appliance.

  • These installation instructions make use of a number of symbols. The meanings of the symbols are shown below.

  • Observe this instruction in order to prevent injury and damage to property.

Warnings before installation

  • This appliance complies with the applicable safety instructions. However, inexpert installation may cause personal injury or damage to the appliance.
  • The appliance is intended exclusively for household use (preparation of food) and excludes all other domestic, commercial or industrial use. Do not use the appliance outside.
  • Check the condition of the appliance and the installation fittings as soon as you remove them from the packaging. Remove the appliance from the packaging with care. Do not use sharp knives to open the packaging.
  • Do not install the appliance if it is damaged, and in that case inform Novy.
  • Check on the basis of the drawing A that all the materials for installation have been supplied. The grease filters are in the appliance.
  • Novy is not liable for damage resulting from incorrect assembly, incorrect connection, incorrect use or incorrect operation.
  • The installation and electrical connection of the appliance should be left to a recognised expert.
  • Safety is guaranteed only with expert installation in accordance with the installation manual. The installing technician is responsible for proper operation at the installation location.
  •  For easier installation of the appliance, it is advisable to carry it out with at least 2 people.
  •  Read the directions for use and the installation instructions before installing and using this appliance. You will find important information here for the assembly and use of the appliance.
  • Metal parts may have sharp edges, and you may injure yourself on them. For that reason, wear protective gloves during installation.

Installation instructions for the appliance

  • Ensure that the structure on or in which the appliance is to be installed can bear its weight.
  • Faulty or damaged parts may only be replaced by original Novy parts.
  • The larger the distance between the appliance and the hob, the less easily the cooking vapours can be taken up by the appliance. For this reason, pay heed to the stated (recommended) installation height.
  • If a different distance is specified in the installation instructions for the gas hob, the largest distance indicated applies.
  •  In order to ensure that the cooking vapours are taken up in an optimal way, the appliance, or the structure into which the appliance is being installed, should extend over the hob. When using your own structure, ensure that the appliance is installed centred above the hob.
  • For optimal operation, the hob should not be larger than the appliance or the structure into which the appliance is installed.

Recirculation
The cooker hood can only be used as a recirculation cooker hood. The cooking vapours are cleaned by the grease filters and an recirculation filter and returned to the kitchen.

Air supply
With an appliance with recirculation, there must be a minimum of ventilation in the room where the appliance has been installed / is positioned. Ventilation can be provided by the overall ventilation in the home or by
tilting a window or opening a door.

Installation instructions for the outlet

  • The appliance may only be connected with the power plug to a socket with an earth (230 V – 50 Hz).
  •  Safety is only assured when the appliance is connected to an earth cable in accordance with the instructions laid down.
  • The appliance must be able to be disconnected from the power at any desired point.
  • Position the socket in such a way that the power plug of the appliance can be inserted easily.
  •  Do not use an extension cable for the connection to the electrical mains.
  • Electric shock: never switch on a faulty appliance, this could cause an electric shock. Take the power plug out of the socket, or switch off at the distribution cabinet. Contact the Novy service department.
  • Repairs and replacing faulty or damaged wiring must only be carried out by technicians who have undergone instruction by Novy.
  • Moisture that has got into the appliance may cause an electric shock. Do not use a high pressure or steam cleaner.

ACCESSORIES

InTouch

  • InTouch offers you the possibility to control the Novy cooker hood from the Novy InTouch induction cooking hob. The cooker hood can be combined with Novy InTouch induction hobs using the optional InTouch kit. Kit for InTouch includes an interface and a remote control.
  • The new interface must be fitted before installing the cooker hood as a replacement for the original interface.
  • The kit must be installed by an authorised person.
  • Visit the website for the different models of induction cooking plates with InTouch.
  • Further information on Novy products, accessories and services may be found on the internet: www.novy.co.uk

DIMENSION

NOVY-7836-Wall-Mounted-Hood-fig-2

Because of the substantial own weight of the hood, the contruction must have sufficient load bearing capacity.

Electrical connection

  • The cooker hood is equipped with a power cord and plug with grounding.
  • Connect the plug to a mains socket with grounding.
  • Connection via a mains socket is recommended.
  • Mount the mains socket easily accessible.
  • It must be possible to disconnect the cooker hood from the power supply at any time (e.g. in case of service).

Connecting the cooker hood

  • The socket is placed directly above the cooker hood (minimum distance 30mm)
  • Plug the cooker hood plug into the mains socket.
  • The plug and socket are visible!
    Check on the basis of the drawing A that all the materials for installation have been supplied. The grease filters are in the appliance.

INSTALLATION INSTRUCTION

  1. Determine the mounting height ‘h’ above the hob:
    • Recommended mounting height with induction, electric or ceramic hob (Hmin-Hmax) (mm): 500 – 750
    • Mounting height with a gas hob (Hmin-Hmax) (mm): 650-750.
  2. To avoid draughts above the cooking surface, the minimum distance between the topside of the cooker hood and ceiling should be at least 250 mm.
    • The height at which the 2 mounting hooks are mounted is determined by: chosen height “h” + 480 mm. Draw a level horizontal line at this height.
    • Drill the holes in the wall using an 12 mm drill. The distance between the 2 holes is 510 mm (ensure that hood is positioned centrally above the cooker plate)
  3. Mount the 2 suspension hooks in the wall. The suspension can be levelled by adjusting the adjustment screws (at the bottom). This can be done in advance, or after the cooker hood has been removed from the wall.
  4. Hang the extraction hood over the mounting brackets.
  5. Grasp the underneath of the glass plate (A) at the left and right and pull it firmly forwards. Open the glass plate so that the grease filter is visible. You can remove the metal grease filter (B) from the hood.
  6. There are 2 holes on the inside of the hood. Mark these holes on the wall. Depending on the wall, you can position the screws directly in the wall or remove the hood from the wall first, drill the holes, and use the plugs and screws. After this, replace the hood in the brackets and fasten the hood to wall with the 2 screws.
  7. Put the plug into the wall socket.
    Replace the grease filters in the extractor hood.

NOVY-7836-Wall-Mounted-Hood-fig-3 NOVY-7836
-Wall-Mounted-Hood-fig-4

Dimensions

7836 – 7838 – 7839

NOVY-7836-Wall-Mounted-Hood-fig-6

7848 – 7849

NOVY-7836-Wall-Mounted-Hood-fig-7

7856 – 7858 – 7859

NOVY-7836-Wall-Mounted-Hood-fig-8

ABOUT COMPANY

  • NOVY nv
  • Noordlaan 6
  • B – 8520 KUURNE
  • Tel. 056/36.51.00
  • Fax 056/35.32.51
  • E-mail: novy@novy.be
  • http://www.novy.be
  • France: Tél: 0320.940662
  • Deutschland und Österreich: Tel: +49 (0)511.54.20.771
  • Nederland: Tel.: +31 (0)88-0119110
  • United Kingdom: +44 (0)207 866 2493
  • España: Tel.: +34 938 700 895
  • Italia: Tel.: +39 039.20.57.501

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals